Fire Alarm System Operation

Introduction to Fire Alarm System Operation

Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the installed smoke and heat detectors will automatically send signals to your Control/Communicator, triggering a loud interrupted sound from the keypad. An interrupted sound will also be produced by optional exterior sounders. A FIRE message will appear at your keypad and remain on until you silence the alarm.

In Case of Fire Alarm

1.Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad and manually initiate an alarm by pressing the panic key assigned as FIRE emergency (if programmed by the installer) and hold down for at least 2 seconds.

2.Evacuate all occupants from the premises.

3.If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately.

Silencing and Clearing a Fire Alarm

1.Silence, acknowledge, and clear the alarm by:

a.For Residential Systems: Press “Touch here to Silence” on the display to silence the alarm.

For Commercial Systems: Enter your code. This will silence and acknowledge the alarm and disarm the system (if armed).

b.Press the CLEAR button followed by your code. This will acknowledge the alarm and disarm the system (if armed).

c.Press the DISPLAY FAULTS button on the Arming screen. The faulted fire zone will be displayed.

d.Press the CLEAR button and then enter your code. This will clear the Fire Alarm from the system.

2.If the keypad does not indicate a READY condition after the second sequence, press the DISPLAY FAULTS key on the Arming screen to display the zone(s) that are faulted. Be sure to check that smoke detectors are not responding to smoke or heat

30

Image 30
Contents Ademco 6271 Series TouchCenter Keypads Table of Contents Table of Contents Contd Glossary About the TouchCenter IntroductionTouchCenter Interface About the TouchCenter contd Navigating through the TouchCenterAbout Your Home Screen Navigation Icon Descriptions Icon Location FunctionTouchCenter Arming Screen AwayStay Choices NightMore Icon MeaningSystem Overview Introduction to Your SystemBurglary Protection System Overview Contd Fire ProtectionUser Codes Safe ModeCarbon Monoxide Protection Extended FunctionalitySystem Overview Contd System Overview contd Arming Exit Entry Perimeter Interior Mode Delay Armed How to Arm the SystemFeatures for Each Arming Mode Security System OperationSecurity System Operation contd Screen ActionHow to Arm Multiple Partitions To arm multiple partitionsARM Selected How to Display Faults Bypass Zones, Enter CodeHow to Bypass Zones BypassTo bypass zones do the following Press the Bypass Selected How to Remove Bypassed Zones How to Clear a Control Panel Message How to Hide a Control Panel MessageEnter your Authorized Code How to Disarm the System To disarm the system when entering the premisesArm or Not Ready Fault if any zone is Disarm Selected button.How to Check the Status of Other Partitions Enter the code authorized to access How to Send Emergency Messages Next and Previous buttons will How to View the Event LogWhen All Partitions or All Events Next and Previous buttonsCase of Fire Alarm Fire Alarm System OperationIntroduction to Fire Alarm System Operation Silencing and Clearing a Fire AlarmFire Alarm System Operation Contd Case of Carbon Monoxide AlarmSilencing and Clearing a Carbon Monoxide Alarm Fire Alarm System Operation contd User Code Setup Introduction to User Code SetupAuthority Levels User Code Setup contd How to Access User SetupAccess User Setup as follows How to Add a User Add a user as followsAuthorized Code Enter User Code… displayed DigitsSelected, the Allow Arm/Disarm from How to Delete a User Delete a User as followsHow to Edit a User Edit a user as followsInstructions Enter Authorized Code Advanced System Features Introduction to Advanced System FeaturesConsole Emulation Mode Advanced System Features Contd How to Enter Console Emulation ModeTo access the TouchCenter Keypad, do the following Voice Messages 6271V/6271CV Only Introduction to Recording and Retrieving MessagesVoice Messages Contd Recording a Voice MessageRetrieving and Deleting a Voice Message To retrieve a voice message, do the followingLED Description Armed Summary of LED OperationLED Operation On Security system is armedHow to Access Setup TouchCenter SetupHow to Access TouchCenter Setup Options Access the Setup features as followsTouchCenter Setup Contd How to Adjust the ContrastHow to Adjust the Volume How to Select Screen Backlight Off Activation Time Button. a Settings Changed! pop-upBacklight Off After arrow button. a How to Select Homepage After Time TouchCenter Setup Contd How to Set the Time and Date Setting Daylight Savings TimeTouchCenter Setup Contd Setting Current Time To set the current time, do the followingTouchCenter Setup Contd TouchCenter Setup Contd TouchCenter Setup Contd Operating Modes Operating Modes Chime, Voice, and Voice ChimeTouchCenter Operating Modes contd How to Access Operating ModesAccess the Operating Modes feature as follows Press the Operating ModesHow to Access Language Selection How to Clean your TouchCenter Clean the TouchCenter as followsMaintaining Your System Routine Care Glossary Glossary Contd ONE Year Limited Warranty

6271 specifications

The Honeywell 6271 is an advanced security keypad designed to enhance user experience while providing robust safety features for home and business environments. This versatile keypad is primarily used in Honeywell's security systems and is well-regarded for its user-friendly interface and array of functions.

One of the standout features of the Honeywell 6271 is its large, intuitive touchscreen display. The 7-inch screen allows for easy navigation through the various options, making it simple for users to arm or disarm their security system, view system status, and access other settings. The high-resolution display enhances visibility, ensuring ease of use even in low-light conditions.

The Honeywell 6271 incorporates built-in Z-Wave technology, which supports seamless integration with a wide range of smart home devices. This feature allows users to control locks, lights, and thermostats directly from the keypad, thereby streamlining home automation and enhancing convenience. Additionally, the Z-Wave capabilities enable remote management, allowing homeowners and business owners to monitor and control their security settings from their smartphones or tablets.

Another significant aspect of the Honeywell 6271 is its compatibility with various Honeywell security systems. This ensures that users can easily incorporate the keypad into their existing setups without the need for extensive modifications. The device is designed to work alongside Honeywell's alarm systems, providing a cohesive and efficient response to potential security threats.

In terms of security, the Honeywell 6271 features advanced encryption and authentication measures, offering enhanced protection against unauthorized access. The keypad supports user-defined codes, enabling multiple family members or staff to have their unique access credentials. Moreover, built-in alarm functionality allows for immediate alerts in the event of a breach, ensuring that users are quickly informed of any suspicious activity.

Aesthetically, the Honeywell 6271 boasts a sleek and modern design that can complement any interior décor. Its ergonomic layout and responsive touch interface make it not only an effective security tool but also a stylish addition to any home or office.

In summary, the Honeywell 6271 combines cutting-edge technology with practical usability, boasting features such as a large touchscreen display, Z-Wave integration, robust security measures, and compatibility with existing security systems. This keypad exemplifies Honeywell’s commitment to providing innovative and efficient solutions for modern security needs. Its advanced features make it an essential component of any comprehensive security system.