956 SERIES

WHITE-RODGERS

Flame Detector

 

INSTALLATION INSTRUCTIONS

 

 

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

This solid-state electronic flame detector utilizes light intensity to sense the presence of the flame in oil burning systems.

DESCRIPTION

On flame failure, the detector will cause the primary control to shut down the main burner. This flame detector can be interchanged with similar type flame detectors.

THIS DETECTOR MUST BE INSTALLED BY A QUALI- FIED INSTALLER.

All wiring must conform to local and national electrical codes and ordinances.

This detector is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the detector to malfunction.

!WARNING

Do not use on circuits exceeding specified volt- ages. Higher voltages will damage unit and could cause shock or fire hazard.

If in doubt about whether your wiring is millivolt, low or line voltage, have it inspected by a quali- fied heating and air conditioning contractor or a licensed electrician.

PRECAUTIONS

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dangerous operation

Following installation or replacement, follow appliance manufacturers’ recommended instal- lation/service instructions to insure proper operation.

To remove the old cell from the bracket:

Disconnect wires from terminals on primary control. Rotate cell counterclockwise in bracket.

Slide the cell out of the bracket through the notched opening in the bracket.

To install new cell:

Insert new cell through notched opening in bracket. Rotate cell clockwise to lock into position.

Connect wires to terminals on primary control.

INSTALLATION

!CAUTION

Do not disturb the bracket position during re- placement of cell assembly.

If bracket is moved or new bracket is installed, follow the equipment manufacturers' recommendations for proper positioning.

NOTE

Cell assembly cannot be installed properly if bracket is installed backwards.

Wiring

All wiring must conform to local and national electrical codes and ordinances.

Make electrical connections to F-F terminals on primary control.