White Rodgers 1F84-51 specifications Description, Precautions, Specifications, Part no -5739A

Page 1

1F84-51

Programmable Electronic Digital

WHITE-RODGERSHeat Pump Thermostat

INSTALLATION AND

OPERATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Your new White-Rodgers 7-Day Digital Heat Pump Thermostat uses the technology of a solid-state microcomputer to provide precise time/temperature control. This thermostat offers you the flexibility to design heating and cooling programs that fit your needs.

Features:

Separate program for each day of the week

Simultaneous heat and cool program storage

Preprogrammed temperature control

Four separate time/temperature settings per 24 hour period

LCD continuously displays set point, and alternately dis- plays time and room temperature

Temperature override until next program period

Manual program override (HOLD temperature)

°F/°C convertibility

Temperature range 45° to 90°F

Eight terminals for single or two-transformer systems

O/B terminal for heat pump systems

Armchair Programming Capability

This thermostat is intended for use with a 24 volt system; do not use this thermostat with a millivolt or line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.

PRECAUTIONS

!CAUTION

To prevent electrical shock and/or equipment damage disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

!WARNING

Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.

Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.

ELECTRICAL DATA

Electrical Rating:

20 to 30 VAC 50/60 Hz. or D.C.

0.05 to 1.5 Amps (Load per terminal)

1.5Amps Maximum Total Load (All terminals combined)

THERMAL DATA

Setpoint Temperature Range:

45°F to 90°F (7°C to 32°C)

Operating Ambient Temperature Range:

32°F to 105°F

Operating Humidity Range:

0 to 90% RH (non-condensing)

Shipping Temperature Range:

-40°F to 150°F

SPECIFICATIONS

APPLICATIONS

For use with:

Heat pump systems with up to two stages heat, one stage cool

DO NOT USE WITH:

Millivolt systems

Systems exceeding 30 VAC and 1.5 amps

3-wire zoned hydronic heating systems

WHITE-RODGERS DIVISION

 

PART NO. 37-5739A

EMERSON ELECTRIC CO.

Printed in U.S.A.

Replaces 37-5613C

9797 REAVIS ROAD

 

9637

ST. LOUIS, MISSOURI 63123-5398

 

 

 

Image 1
Contents Specifications PrecautionsDescription Part no -5739AEnergy Management Recovery EMR InstallationRemove OLD Thermostat Attach Thermostat Base to WallTypical wiring diagram for single transformer systems Adjustable Anticipation Terminal Switch SelectionArmchair Programming Check Thermostat OperationThermostat Buttons and Switches Operating FeaturesOperation Thermostat BaseHeat Temperatures Cool Temperatures Select Heating TemperaturesProgramming Your Thermostat Entering Your ProgramHeating/Cooling Schedule Plan Enter Heating/Cooling Times and Heating TemperaturesEnter Cooling Temperatures Select Cooling TemperaturesIf the temperature displayed is not the Cool 1, 2, 3, or Check Your Programming