White Rodgers pmnACM/ACB owner manual Positions DE Montage Typiques

Page 13

POSITIONS DE MONTAGE TYPIQUES

ÉCOULEMENT DE L’AIR

Figure 5

GÉNÉRATEUR DE SOUS-SOL (À CAISSONS JUXTAPOSÉS) (figure 5)

Installer l’épurateur à l’horizontale dans le plénum de reprise d’air, juste au-dessus du générateur.

ÉCOULEMENT DE L’AIR

Figure 6

GÉNÉRATEUR À CIRCULATION À CONTRE- COURANT (figure 6)

Installer l’épurateur à l’horizontale dans le plénum ou le conduit de reprise d’air, juste au-dessus du générateur.

ÉCOULEMENT DE L’AIR

Figure 7

GÉNÉRATEUR À CAISSONS SUPERPOSÉS (figure 7)

Installation latérale. Installer l’épurateur à la verticale, là où la reprise d’air pénètre dans la prise d’air latérale du générateur.

GÉNÉRATEUR À CAISSONS SUPERPOSÉS

(figure 8)

Installation sous le générateur d’air. Installer l’épurateur à l’ho- rizontale, là où la reprise d’air pénètre par en-dessous. Soule- ver le générateur d’air et instal- ler l’épurateur sous la base.

ÉCOULEMENT DE L’AIR

MOINS DE

 

18 cm (7 po)

DÉVIATION

AU MOINS 23 cm (9 po)

FIGURE 9

ÉCOULEMENT

DE

L’AIR

 

INSTALLATION AVEC DÉVIATION (figure 9)

Utilisation typique d’un conduit coudé pour adapter l’épu- rateur à l’ouverture.

Si le raccordement du conduit sur le générateur d’air chaud laisse moins de 23 cm (9 po) où installer l’épura- teur, il faut raccourcir la section latérale ou installer une section coudée pour compenser.

GÉNÉRATEUR HORIZONTAL (figure 10)

Installer l’épurateur à la verticale

Figure 10dans le conduit de reprise d’air, près du générateur.

5

Image 13
Contents Part no -6383C ACM/ACBIntroduction Construction of the AIR Filter Compartment HOW the AIR Filter WorksLocating the AIR Filter PreinstallationModel No Basement Furnace Lowboy Figure Typical Mounting PositionsFurnace Figure Highboy Furnace FigureRemove OLD Filter and Discard Clean Blower Compartment InstallationInstallation Transition FittingsAlways order by Part Number Not by Item Number MaintenanceDescription 1000 1400 1600 2000 1200TM 2000U 2000X White-Rodgers Electronic Air Cleaner Guide DE L’UTILISATEUR ACM/ACBGarantie IntroductionTable DES Matières Outils DE Base RequisConstruction DE L’ÉPURATEUR Fonctionnement DU Filtre À AIRChoix DE L’EMPLACEMENT DE ’ÉPURATEUR Installation PréliminaireGénérateur DE SOUS-SOL À Caissons Juxtaposés figure Positions DE Montage TypiquesInstallation InstallationNettoyer LE Compartiment DU Ventilateur Pièces DE Rechange ET DE Mise À Niveau EntretienAvis AUX Consommateurs

pmnACM/ACB specifications

The White Rodgers pmnACM/ACB series represents a significant advancement in HVAC control technology, designed to enhance the efficiency and functionality of heating, ventilation, and air conditioning systems. This product line, often employed in residential and commercial applications, is lauded for its reliability, precision, and smart features.

One of the standout characteristics of the pmnACM/ACB is its integrated technology that enables intuitive control over heating and cooling systems. The units come equipped with embedded Wi-Fi capabilities, allowing users to remotely manage their HVAC systems via a smartphone app or web interface. This connectivity not only facilitates real-time monitoring but also enables users to adjust settings from virtually anywhere, helping to conserve energy and maintain comfort.

Additionally, the pmnACM/ACB utilizes advanced sensor technology to provide accurate temperature readings and system performance feedback. This ensures optimal operation and can lead to reduced energy costs by adapting to the user’s habits and preferences. Smart algorithms are employed to learn usage patterns, allowing the system to make automatic adjustments to maintain ideal comfort levels while maximizing efficiency.

Another innovative feature is the programmable scheduling function, which allows users to create customized heating and cooling schedules tailored to their lifestyle. It supports multiple settings throughout the day, catering to variations in occupancy and preferences, which not only enhances comfort but also contributes to energy savings.

The White Rodgers pmnACM/ACB series is designed with user-friendliness in mind. The intuitive interface includes a clear, easy-to-read display, making it simple for users to navigate through settings and make adjustments as needed. Installation is also straightforward, with a user manual that provides step-by-step instructions, facilitating a hassle-free setup experience.

Durability is a key characteristic of this product line, as it is constructed from high-quality materials to withstand varying environmental conditions. The robust design ensures a long operational lifespan, making it a wise investment for homeowners and businesses alike.

In summary, the White Rodgers pmnACM/ACB series combines smart technology, ease of use, and durability to deliver an effective solution for HVAC control. With features like remote access, programmable scheduling, and advanced sensor technology, users can enjoy a comfortable environment while optimizing energy consumption and reducing utility costs.