Whirlpool E2F30LD035V, 6510413 Installation Checklist, Water Heater Location, Water System Piping

Page 8

Devices for Hot Water Supply Systems, ANSI Z21.22 - latest edition. This valve must be marked with the maximum set pressure not to exceed the marked maximum working pressure of the water heater. Install the valve into an opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from the valve exits only within 6 inches above, or at any distance below, the structural fl oor, and does not contact any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstance.

IMPORTANT: Only a new temperature and pressure relief valve should be used with your water heater. Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater. Do not place any valve between the relief valve and the tank.

The Temperature & Pressure Relief Valve:

Shall not be in contact with any electrical part.

Shall be connected to an adequate discharge line.

Shall not be rated higher than the working pressure shown on the data plate of the water heater.

The Discharge Line:

Shall not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line.

Shall not be capped, blocked, plugged or contain any valve between the relief valve and the end of the discharge line.

Shall terminate a maximum of 6 inches above a floor drain or external to the building.

Shall be of material listed for hot water distribution.

Shall be installed to allow complete drainage of both the valve and discharge line.

Solar Installation

If this water heater is used as a solar storage heater or as a backup for the solar system, the inlet water supply temperatures to the water heater tank may be in excess of 120°F. A tempering valve or other temperature limiting valve must be installed in the inlet water supply line to limit the supply temperature to 120°F.

NOTE: Solar water heating systems can often supply water with temperatures exceeding 180°F and may result in water heater malfunction.

INSTALLATION

CHECKLIST

Water Heater Location

Centrally located with the water piping system.

Located indoors and in a vertical position. Protected from freezing temperatures.

Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain.

Sufficient room to service the water heater.

Water System Piping

Temperature and pressure relief valve properly installed with a discharge line run to an open drain and protected from freezing.

All piping properly installed and free of leaks.

Heater completely filled with water. (See Figure 2)

Closed system pressure buildup precautions installed.

Tempering valve (when applicable) installed per manufacturer’s instructions (see “Water Temperature Regulation” section).

Electrical Connections

Wiring and connections comply with all applicable codes.

Water heater and electrical supply are properly grounded.

Proper overload fuse or circuit breaker protection installed.

8

Image 8
Contents Installation Instructions Use & Care Guide Water Heater Safety Your safety and the safety of others are very importantInstalling Your Water Heater Consumer InformationConsumer Responsibilities Unpacking the Water HeaterLocation Requirements Site locationElectrical Requirements Piping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionInstallation Checklist Water Heater LocationWater System Piping Electrical ConnectionsOperating Your Water Heater Before UsingWater Temperature Regulation Adjusting the Thermostat/High Limit Control Reconnect powerOperational Conditions Anode Rod/Water OdorWater Heater Sounds StackingDraining and Flushing Maintenance of Your Water HeaterHeating Element Replacement Troubleshooting Chart Problem Possible CausesRepair Parts Repair Part IllustrationThermostat Wiring Diagram Branch Circuit Sizing Guide

140389, 140449, 121802, E1F50RD045V, 140426 specifications

Whirlpool has been a trusted name in home appliances for decades, and their line of air conditioners is no exception. Models such as the E2F40HD045V, E2F40RD045V, E2F50HD045V, and E1F20US015V 120V,6510413 showcase the brand's commitment to quality, efficiency, and user-friendly features that enhance indoor comfort.

The E2F40HD045V is a high-efficiency air conditioning unit designed for maximum cooling performance while minimizing energy consumption. This model utilizes advanced inverter technology, allowing it to adjust its cooling capacity based on the room's needs. This feature not only improves energy efficiency but also ensures a more stable and comfortable indoor climate by constantly monitoring and adjusting the output.

The E2F40RD045V stands out with its robust construction and sleek design, making it an attractive addition to any room. Its compact size is ideal for smaller spaces, while still providing powerful cooling capabilities. With clear air filtration systems, it ensures that the air circulating within your home is clean, which is especially beneficial for allergy sufferers.

The E2F50HD045V takes things a step further with its added features such as programmable thermostats and remote control operation. Homeowners can easily set their desired temperature from anywhere in the room, bringing convenience to their air conditioning experience. Coupled with a whisper-quiet operation, this model is perfect for bedrooms and living spaces where noise can be a concern.

On the other hand, the E1F20US015V 120V,6510413 is designed to deliver efficient cooling in compact spaces while ensuring ease of installation. Its lightweight design means that even those with minimal technical skills can set it up without professional help. This model is perfect for apartments or smaller homes, combining efficiency with practicality.

All models feature user-friendly control panels with LED displays, allowing for easy adjustments and monitoring of settings. Additionally, they are equipped with energy-saving modes that promote environmental sustainability without sacrificing performance.

In conclusion, Whirlpool’s E2F40HD045V, E2F40RD045V, E2F50HD045V, and E1F20US015V 120V,6510413 air conditioners are a testament to the brand's innovation and commitment to quality, capping off their efforts with energy-efficient features and technologies that cater to the diverse needs of consumers.