Whirlpool ACS052XH1 Volt models with amperes up through, Plug Type Electrical Requirements See

Page 6

E L E C T R I C A L R E Q U I R E M E N T S

PLUG TYPE

ELECTRICAL REQUIREMENTS

SEE PAGE

3-prong

 

 

ground plug

115-volt models with amperes

 

 

 

6

 

 

 

 

 

 

up through 7.5

 

3-prong

ground-

Ground type outlet prong

Power supply cord

3-prong

ground plug

 

3-prong

For 115-volt models with amperes

7

 

 

ground-

type outlet

from 7.6 to 12.0

 

 

 

 

Ground

prong

Power supply cord

115-volt models with amperes up through 7.5

Outlet wiring

Outlet wiring should be a minimum of

14 gauge. Use copper wire only. It is the responsibility of the consumer to provide proper and adequate receptacle wiring, installed by a qualified electrician. Observe National Electrical Code and all local governing codes and ordinances.

Electrical requirements

A 115-volt (103.5 min., 126.5 max.), 60-Hz, AC-only, 15-ampere fused electrical supply is required (time delay fuse or time delay circuit breaker required). It is required that a separate circuit, serving only this air conditioner, be provided.

Electrical connection

Electrical ground is required on this air conditioner.

Recommended ground method

For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical Code (ANSI/NFPA 70 – latest edition) and local codes and ordinances. If a mating outlet is not available, it is the responsibility of the customer to have a properly grounded 3-prong outlet installed by a qualified electrician.

3-prong ground plug

Ground prong

Power supply cord

3-prong ground-type outlet (double outlet)

6

Image 6
Contents Installation UseAndCare Part no -11-2112N-004/1183829 Rev. aThank you for buying a Whirlpool appliance Air Conditioner Safety Your safety and the safety of others are very importantParts And Features Control PanelElectrical Requirements Volt models with amperes up through Plug Type Electrical Requirements SeeRecommended ground method Volt models with amperes from 7.6 through Installing Your Air Conditioner Preparing for installationInstallation tips Installing in a sliding window On nextSupport Two 7⁄16 long Platform Failure to do so can result in back or Other injuryInstalling in a casement window Installing in a wood sliding or wood casement windowOperating Your Air Conditioner Starting your air conditionerTo exhaust room air Using the exhaust vent controlChanging air direction To circulate room airCleaning the front panel Caring For Your Air ConditionerReplace air filter Cleaning the air filter Annual maintenance Understanding normal operating sounds Saving energyTroubleshooting Problem Check the FollowingRequesting Assistance or Service When asking for help or serviceT E S T E S Index TopicLength of Warranty Whirlpool will PAY for Whirlpool will not PAY for