CTFIDSettings Tree Options en 49
Feature | Description | Device | Default | Options |
|
|
|
|
|
Title | G3A Series, ENV Series, | (blank | (blank field) | |
| displayed when the Dome moves | VG4 Series | field) |
|
| to a scene (must be enabled or |
|
|
|
| disabled via the Title OSD). |
|
|
|
|
|
|
|
|
Title OSD | Controls how the camera | G3A Series, ENV Series, | Momentary | On, Off, |
| displays the | VG4 Series |
| Momentary |
| and Scene titles. |
|
|
|
| Options include: |
|
|
|
| Off: No |
|
|
|
| displayed. |
|
|
|
| On: Always displays |
|
|
|
| titles. |
|
|
|
| Momentary: |
|
|
|
| displayed for a few seconds, then |
|
|
|
| hidden (default). |
|
|
|
|
|
|
|
|
Tour Period | Controls the waiting time until | G3A Series, ENV Series, | 5 sec. | 3 sec. to 10 min. |
| the dome moves to the next | VG4 Series |
|
|
| scene. |
|
|
|
|
|
|
|
|
Track | Alarm input option that turns the | G3A Series, ENV Series | Off | On, Off |
| tracker on when the alarm is |
|
|
|
| activated. |
|
|
|
|
|
|
|
|
Tracker | Automated motion tracking | G3A Series, ENV Series, | Off | On, Off |
| system. | VG4 500 Series |
|
|
|
|
|
|
|
Tracker | Enables or disables | G3A Series, ENV Series | On | On, Off |
Communication | communication between the |
|
|
|
| camera and tracker module. |
|
|
|
|
|
|
|
|
Tracker Period | Controls the length of time the | G3A Series, ENV Series, | Follow | Follow Input, |
| tracker is activated. |
| Input | 1 sec. to 10 min., |
| Follow Input: Tracker remains |
|
| Latched |
| activated for the same amount of |
|
|
|
| time the alarm input is activated. |
|
|
|
| Latched: Tracker stays on until |
|
|
|
| the operator clears it. |
|
|
|
|
|
|
|
|
Transmit | Alarm input option that enables a | G3A Series, ENV Series | Off | On, Off |
| Bilinx alarm message to be |
|
|
|
| transmitted to the head end |
|
|
|
| equipment. |
|
|
|
|
|
|
|
|
Trigger | Alarm output option that selects | G3A Series, ENV Series | (none | Input 1, Input 2, |
| the input to control the alarm |
| selected) | Input 3, Input 4 |
| output. |
|
|
|
|
|
|
|
|
Vertical Phase | Adjusts the vertical phase offset. | Dinion 2X, DinionXF, | 0 | 0 to 358 |
|
| FlexiDome, FlexiDome 2X, |
|
|
|
| Unity |
|
|
|
|
|
|
|
Bosch Security Systems, Inc. | User’s Manual | F.01U.141.545 3.09 2009.10 |