Tyco PC1150 instruction manual Master Code, Arming the System

Page 5

Master Code

The 4-digit Master Code is used to arm and disarm the security system, to program additional Access Codes and to change other system features. The Master Code will be supplied to you by your installer. All keypad entries are made by pressing one key at a time.

Arming the System

Check the following items before arming the system:

Bypassed Zones

If the “System” light is ON, ensure that zones are intentionally bypassed before arming the system (See Zone Bypassing section).

Trouble Indications

The “System” light is also used to warn of trouble conditions in the system. If the “System” light is ON, check to see what the trouble condition is and call for service. (See Viewing Trouble Conditions section).

Ready Light

If the “Ready” light is NOT ON, check to see that all doors and windows are closed and that motion is stopped in areas covered by motion detectors. The system cannot be armed unless the “Ready” light is ON, indicating that all zones are closed.

NOTE: The system may be armed with a zone bypassed or a trouble present but your security protection will be reduced.

To Arm The System

Enter your 4-digit Access Code. As each digit is entered, the keypad sounder will beep. If the correct Access Code is entered, the keypad sounder will beep quickly and the “Armed” light will come ON.

If the Access Code was entered incorrectly or the “Ready” light comes ON, the keypad buzzer will sound steadily for 2 seconds. If this occurs, press the [#] key and re-enter your Access Code.

When the correct Access Code is entered and the “Armed” light comes ON, exit the premises through the door indicated by your installer as the Exit-Entry door. At the end of the exit delay period, all lights, except the “Armed” light, will go out and the system will be armed. The exit time delay can be changed by your installer.

Auto-Bypass Option - Home-Away Arming

This feature, if selected by your installer, will allow you to arm your system with any Access Code and the system will automatically bypass the interior zones. When activated, the “System” light will come on. If you exit within the allowed exit time, the system will automatically activate the interior zones and the “System” light will go out. This feature is designed to save the customer from having to manually bypass interior zones each time they wish to arm the system and remain at home.

In residential applications where the system has been armed and the interior zones are automatically bypassed, the interior zones can be reactivated from a keypad that is outside the interior zone's protection area. To reactivate the interior zones, press [] then [1] and the “System” light will go out.

Entry Delay Off Arming

If you wish to arm your system and eliminate the entry delay, enter [][9] before your Access Code. The “Armed” light will flash as a reminder that the system is armed and has no entry delay. An entry through any zone programmed as a delay zone will create an instant alarm.

To arm without entry delay, press [][9][Access Code]

3

Image 5
Contents Instruction Manual FCC Compliance System Information General System Operation TestingAbout Your Security System Arming the System Master CodeDoor Chime Feature Quick Arm FeatureAlarm Test Disarming the SystemOne-Time Use Code Programming Access CodesAlarm Memory Display Zone Bypassing If An Alarm SoundsViewing Trouble Conditions To bypass zonesKeypad Zones PC1150 KeypadKeypad Zones Testing Your SystemMaintenance Limited Warranty 29000525 R0 November 22

PC1150 specifications

The Tyco PC1150 is an innovative, versatile platform designed to meet the demanding needs of various industrial and commercial applications. This programmable controller is engineered to provide reliable performance and ease of use, making it an ideal solution for automation in manufacturing, processing, and control systems.

One of the standout features of the PC1150 is its robust processing power. Equipped with a high-performance microprocessor, the controller can execute complex tasks and handle multiple I/O operations simultaneously. This capability ensures that production processes remain efficient and responsive to real-time changes in operational parameters.

The PC1150 supports a wide range of communication protocols, allowing it to integrate seamlessly with different types of equipment and devices. This flexibility is critical in modern facilities where equipment from various manufacturers must work together to optimize performance. The controller's Ethernet, RS-232, and RS-485 interfaces facilitate smooth communication, making it compatible with other automation systems, including SCADA (Supervisory Control and Data Acquisition) platforms.

A key characteristic of the Tyco PC1150 is its modular design. Users can easily customize the system by adding or removing I/O modules to meet specific application needs. This scalability means that the system can grow alongside business demands, reducing the need for costly replacements or upgrades.

In terms of software, the PC1150 is compatible with intuitive programming languages, including ladder logic and function block diagrams. This user-friendly environment enables engineers and technicians to develop, test, and deploy automation solutions more efficiently. The built-in diagnostic tools and user-friendly interface further streamline the programming process, allowing for rapid troubleshooting and system optimization.

Another notable feature of the Tyco PC1150 is its rugged design. Built to withstand harsh industrial environments, the controller is resistant to dust, moisture, and extreme temperatures. This durability ensures steady performance, minimizing downtime and maintenance costs associated with environmental factors.

Energy efficiency is another aspect where the PC1150 excels. By efficiently managing energy consumption, the controller helps businesses reduce operational costs while contributing to environmentally sustainable practices.

In summary, the Tyco PC1150 is a powerful, flexible, and durable programmable controller designed for a wide range of industrial applications. Its advanced processing capabilities, extensive communication options, modular system design, user-friendly programming environment, and energy efficiency make it an excellent choice for businesses looking to enhance their automation systems.