LST BCnet216: 19 manual Fire Detection Control Panel, Description

Page 1

Fire Detection Control Panel

BC216/BCnet216: 19“ Compact Version

Compact control panel with display and operating field for small and mid- sized systems

BCnet sectional control panel without display and operating field

Low profile 19“ cabinet installation

Analogue ringbus technology with unshielded detector cabling

Addressable conventional technology

EN 54/VdS-certified

Fire is a permanent threat to life and property. There- fore, immediate response to a fi re is imperative. The main objective of the fi re detection control panel Series BC216 is to alarm and to react in time and, conse- quently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a 32-bit multiprocessor system, the fi re detection control panel Series BC216 ensures topmost effi ciency and speed – prerequisites for saving lives and minimi- zing damage to property.

Description

The Fire Detection Control Panel BC216-1CE is a mo- dularly designed compact control panel in 19“ slide-in technology for small and mid-sized fi re detection sys- tems. The extensive functions and features correspond to the Fire Detection Control Panel BC216-1 to the full extent.

By installing a Network Interface Module NIF5-1M, the BC216-1CE can be expanded to form a BCnet sectional control panel.

The BCnet Sectional Control Panel BC216-3CE is a mo- dularly designed sectional control panel in 19“ slide-in technology without display and operating fi eld („Black Box“ control panel) for the application in a Fire Detec- tion Control Panel BCnet216.

All BCnet sectional control panels are connected with each other via a redundant high-security network (the Global Security System network GSSnet). Due to the decentralized structure, the failure safety of the entire system is signifi cantly improved compared to conventi- onally designed fi re detection control panels.

Building Safety. Building Security.

Both versions provide two slots for the connection of function modules (Conventional Detector Interface GIF8- 1 or Loop Interface LIF64-1) to which a total of 16 de- tector lines in addressable conventional technology or a total of two ADM loops or a combination of the both can be connected.

The ADM loop principle offers intelligent analogue ring- bus technology with bi-directional data transfer. Each loop provides for the software-aided administration of up to 198 physical address points in a maximum of 128 detector zones. Addressable conventional technology allows for the connection of automatic and non-auto- matic fi re detectors as well as the unambiguous iden- tifi cation of the activated detector in the event of an alarm.

Easy parameterisation on the control panel‘s display

 

and operating unit (BC216-1CE) or by means of a PC

 

software enables you to tailor the control panel to your

A

individual requirements.

© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 52114-27

BC216CE_DBL_LST_EN_0804.PDF • PAGE 1

OFFICE@LST.AT • WWW.LST.AT • ALL RIGHTS RESERVED

 

Image 1
Contents Description Fire Detection Control PanelClear Concept Distributed Intelligence in the GSSnet Network Expansion of BC216-1CE Permanent ConnectionExtinguishing Control System SpecificationsControl panel with display and operating unit