SECO-LARM USA SK-1123-FQ warranty Introduction, Dimensions Parts List, Delete User

Page 2

ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

 

TABLE OF CONTENTS

 

Introduction

2

Dimensions

2

Unique Features

3

Wiring – Basic Diagram

4

Specifications

5

Output 2 (NPN Transistor Open Collector)

6,7

Wiring – Example, with Connection to Lock Device and Alarm Arm/Disarm

7

User Code Worksheet

8,9

Wiring – 2 Keypads with Mantrap Interlock

10

Wiring – Auxiliary Accessories

11

Programming Notes

12

LED Indicators

12

Preparing to Program

13

Getting Started

13

User Programming

13

Installer Programming

14

Reprogram the Keypad (Select Data)

15

Reprogram the Keypad (Complete Data Refresh)

15

Delete User

15

Master Code Bypass (DAP jumper)

15

Quick Reference Guide

16

INTRODUCTION

The SK-1123-FQ is the ideal keypad for office, commercial, and home security installations. This self-contained security keypad has a built-in 5-Amp relay output and a 100mA transistor ground output for maximum flexibility when connecting to electronic door strikes, door alarms, door chimes, alarm control panels, or other security and access control applications. The outputs can be programmed for timed (1~999 seconds) or ON/OFF operation.

The SK-1123-FQ can be programmed for up to 100 4-digit to 8-digit user codes for the primary output, and up to 10 4-digit to 8-digit user codes for the secondary output. All programming and code information is stored in non-volatile EEPROM memory to protect the data in case of power loss.

DIMENSIONS

 

 

 

 

 

PARTS LIST

 

5/8‖ (15mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

123/32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(31mm)

 

Keypad x 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diode x 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Security screw x 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Security wrench x 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25/8

 

 

(120mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(66.5mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31/8‖ (80mm)

115/16

(46mm)

ENFORCER FLUSH-MOUNT OUTDOOR ACCESS KEYPAD

REPROGRAM THE KEYPAD (SELECT DATA)

To change certain data in the keypad (such as to delete or change user codes), do the following:

1. Enter programming mode by keying in the master code and the key:

x x x x

The keypad is now in the programming mode.

2.Use the programming instructions on page 13 and 14 to make desired changes to the keypad’s data.

3.Exit the programming mode by pressing the key.

REPROGRAM THE KEYPAD (COMPLETE DATA REFRESH)

Sometimes it may be necessary to completely erase all current data (except the master code) and input new data. An example of when this may be necessary is the sale of a protected building to a new owner. In such a situation, do the following:

1.Enter the programming mode by keying in the master code and the key, then enter the refresh code, 8 9 0 1 and the # key:

x

 

x

 

x

 

x

 

 

The keypad is now in the programming mode.

 

 

 

 

 

 

 

All old data is cleared and the keypad is ready for new data.

8

 

9

 

0

 

1

 

#

Note: The master code does NOT change.

2.Use the programming instructions on pages 13 and 14 to enter the keypad’s data.

3.Exit the programming mode by pressing the key.

DELETE USER

To delete a user who no longer has authority to enter the protected area:

1. Enter program mode by keying in the master code and the

 

key:

 

 

 

 

 

 

 

 

 

 

 

 

x

 

x

 

x

 

x

 

 

The keypad is now in the programming mode.

2. Enter the output #, user ID number, and the # key.

To delete user ID 05 from output #1, press

 

1

 

0

 

5

 

#

 

 

 

 

 

 

 

To delete user ID 1 from output #2, press

 

2

 

 

1

 

#

3. Exit the programming mode by pressing the

 

 

 

key.

 

 

 

 

 

 

 

MASTER CODE BYPASS (DAP JUMPER)

If the master code has been forgotten or does not work, use the DAP (direct access to program) jumper to override the forgotten code and permit direct entry into the programming mode as follows:

1.Disconnect the power supply.

2.Move the DAP jumper from OFF to ON.

3.Reconnect the power supply. The keypad will start beeping.

4.Move the DAP jumper back to the OFF position. The keypad will stop beeping as soon as the jumper is removed.

5.Key in a new master code as follows:

Option*

Key in New Code

Confirm

Exit

 

0

 

 

x

 

x

 

x

 

x

 

 

#

 

 

 

*Zero ―0‖ is for new master code only; see page 13 and 14 for other options.

Note: DAP reset does not change any previously configured settings. DAP will only give direct access to programming by bypassing the master code requirement.

Page 2

SECO-LARM® U.S.A., Inc. SECO-LARM® U.S.A., Inc.

Page 15

Image 2
Contents Indoor Keypads Outdoor Keypads Reprogram the Keypad Complete Data Refresh Dimensions Parts ListIntroduction Delete UserEnforcer FLUSH-MOUNT Outdoor Access Keypad Unique Features Auto or manual code entry checkingSECO-LARM U.S.A., Inc Exit the Programming Mode by Pressing the * KEYBack-Lit Jumper Getting StartedBuzzers and LED Signals Enforcer FLUSH-MOUNT Outdoor Access KeypadLED Indicators Tamper N.C Alarm System Arm-Disarm ControlShunting an N.C. Protection Zone Door SensingDoor #1 Enforcer Flush -MOUNT Outdoor Access Keypad WiringIring Example Wiring, with Connection to Lock Device Door #2SK-1123FQ User Code Chart

SK-1123-FQ specifications

SECO-LARM USA has established itself as a trusted name in the security industry, providing innovative solutions tailored for various applications. One of their standout products is the SECO-LARM SK-1123-FQ, a sophisticated yet user-friendly accessory designed to enhance security systems for both residential and commercial properties.

The SK-1123-FQ is a magnetic door switch, known for its reliability and effectiveness in providing intrusion detection. Its primary function is to alert users when a door or window has been opened, triggering an alarm or activating a security system. Built with high-quality materials, the SK-1123-FQ boasts a rugged construction that ensures durability even in harsh outdoor conditions.

One of the key features of the SECO-LARM SK-1123-FQ is its compact size, which makes installation straightforward and unobtrusive. The switch itself includes a mounting bracket that allows for versatile placement options on doors or windows. This adaptability is essential for users looking to integrate the switch seamlessly into existing security installations.

The unit operates on a normally open circuit, making it compatible with most existing alarm systems. It utilizes a reed switch mechanism, providing a high level of sensitivity and minimizing the chances of false alarms. Additionally, the maximum operating distance between the magnet and the switch is approximately 20mm, which is sufficient for standard installations.

One notable technological aspect of the SK-1123-FQ is its low power consumption, allowing it to be used in battery-operated settings without the worry of draining power resources quickly. This feature is particularly beneficial for remote installations where power sources may be limited.

Another important characteristic of the SK-1123-FQ is its versatility; it can be used in various applications including home security, commercial premises, and industrial facilities. Whether protecting entry points or monitoring access to sensitive areas, this door switch provides a reliable solution.

In summary, the SECO-LARM USA SK-1123-FQ magnetic door switch combines durability, ease of installation, and reliability to create an effective security measure. Its numerous features and technological enhancements make it an excellent choice for anyone looking to bolster their security systems, ensuring peace of mind and enhanced protection against unauthorized access.