4.Press the EDID CAPTURE button (see Figure 8).
The EDID status LED flashes rapidly several times. The new EDID is captured when the LED stops flashing and lights solid.
5.Unplug the power adapter from the mains and disconnect it from the
6.Replace the faceplate and secure the four screws removed in Step 1.
Rotary |
| Resolution |
| Refresh |
Switch |
|
|
| Rate |
Position |
|
|
|
|
0 |
| 1024x768 |
| 60Hz |
(Default) |
|
|
|
|
1 |
| 800x600 |
| 60Hz |
2 |
| 1024x768 |
| 60Hz |
3 |
| 1152x864 |
| 75Hz |
4 |
| 1280x720 |
| 60Hz |
5 |
| 1280x800 |
| 60Hz |
6 |
| 1024x1024 |
| 60Hz |
7 |
| 1360x768 |
| 60Hz |
Rotary | Resolution | Refresh | |
Switch |
| Rate | |
Position |
|
| |
8 | 1440x900 | 60Hz | |
|
|
| |
9 | 1440x1050 | 60Hz | |
A | 1600x1200 | 60Hz | |
B | 1680x1050 | 60Hz | |
C | 1920x1080 | 60Hz | |
D | 1920x1200 | 60Hz | |
E | For future use |
| |
F | For future use |
|
13 |