$UPLQJ￿WKH￿6\VWHP

6LQJOH￿%XWWRQ￿$UPLQJ

The “A”, “B”, “C”, and/or “D” keys on your keypad may have been programmed for single-button arming. Note that while it will not be necessary to use a security code for arming, a security code must always be used to disarm the system.

If Single-Button Arming is programmed:

A function key has been assigned to a specific type of arming: STAY mode, Night-STAY mode, AWAY mode, or STEP-ARMING (see Step-Arming paragraph).

You DO NOT need to enter your user code before pressing the function key (you always need your user code to DISARM the system).

Before arming, close all perimeter doors and windows.

1.Press and hold the assigned function key for 2 seconds (no code is required). Function keys are shown below.

A

1

OFF

2

AWAY

3

STAY

B

4

 

5

TEST

6

BYPASS

C

7

INSTANT

8

CODE

9

CHECK

D

*

READY

0

 

#

 

 

 

 

 

ADT3000-007-V0

Alpha6)%(=-Display:7%61)(83%61

Fixed-Word Display: READY

2. The keypad begins beeping and displays the armed Alpha%61)(=39Display:1%=￿￿￿%;%=)<-823;￿￿￿

message. The red ARMED indicator also lights.

Fixed-Word Display: AWAY

6WHS￿$UPLQJ￿)HDWXUH

Single-Button “Step” arming may have been programmed into one of the lettered keys (A, B, C, or D). Check with your installer to see if this has been done in your system.

If Step-Arming is programmed:

The assigned key provides a choice of three levels of security.

The selected key can be pressed once, twice, or three times, increasing the level of security with each press, as follows

Key

First Press

Second Press

Third Press

Ø

Ø

Ø

Ø

A, B, C, D

Armed-STAY

Armed Night-STAY

Armed-AWAY

 

 

(if programmed)

 

– 16 –

Image 16
Contents 8VHU·V*XLGH $ERXW7KLV0DQXDO 7DEOHRI&RQWHQWV Using Device Commands Paging Feature Event Logging ProceduresMacro Key Programming & Usage Security Codes & Authority LevelsQwurgxfwlrq \VWHP2YHUYLHZ\VWHP%DVLFV Alarms Memory of Alarm\VWHP2YHUYLHZ&RQWLQXHG Zones and PartitionsPhone Access Function Keys$ERXW7KH.H\SDGV HQHUDO,QIRUPDWLRQ$ERXW7KH.H\SDGV&RQWLQXHG XQFWLRQVRIWKH.H\SDGV Offmax Away Stay Instantready Code Chime XQFWLRQVRIWKH.H\SDGV&RQWLQXHGQWU\LWHOD\V QWU\HOD\Partition Partition 2 FA168CKHFNLQJRU2SHQ=RQHV QWU\LWHOD\V&RQWLQXHGLW$ODUPV $UPLQJWKH6\VWHP $UPLQJ&RPPDQGV Mode Press these keys… Keypad Confirms By…Quick Arming 6WHS$UPLQJHDWXUH 6LQJOH%XWWRQ$UPLQJKey First Press Second Press Third Press To arm in the Away mode To arm in the Stay mode8VLQJWKH.H\VZLWFK 8VLQJWKH.H\VZLWFKLVDUPLQJDQG6LOHQFLQJ$ODUPV 8VLQJWKH2@NH\\SDVVLQJ3URWHFWLRQ=RQHV To turn Chime Mode on To turn Chime Mode off\SDVVLQJ3URWHFWLRQ=RQHV KLPH0RGH9LHZLQJWKH&XUUHQWDWHDQG7LPH 6HWWLQJWKHDWHDQG7LPHThis Function Sends this signal With This Sounding… 3DQLF.H\V8VLQJ3DQLF.H\V To active a Panic Function0DFUR.H\3URJUDPPLQJ8VDJH $ERXW0DFUR.H\VDPSOHRI0DFUR3URJUDPPLQJ 0DFUR.H\3URJUDPPLQJ8VDJHFRQW8VLQJD3URJUDPPHG0DFUR.H\ 8VLQJHYLFH&RPPDQGV $ERXWHYLFH&RPPDQGVTo Activate Devices To Deactivate Devices3DJLQJHDWXUH $ERXW$XWRPDWLF3DJLQJ0DQXDO3DJLQJ DWFK.H\3DJLQJ$ERXW6HFXULW\&RGHV 6HFXULW\&RGHV$XWKRULW\/HYHOV$XWKRULW\/HYHOHILQLWLRQV +RZWR$VVLJQ8VHU&RGHVDQG$WWULEXWHV 272&RPPDQGDQG0XOWL3DUWLWLRQ$UPLQJ $FFHVVLQJ2WKHU3DUWLWLRQV$$ERXW$FFHVVLQJ3DUWLWLRQV 0XOWL3DUWLWLRQ$UPLQJ 8VLQJWKH*R7R&RPPDQG+ ∗ + partition number 0,1,2,3 RPPRQ=RQH2SHUDWLRQ $ERXW6FKHGXOLQJ 6FKHGXOLQJUHDWLQJ6FKHGXOHV 6FKHGXOLQJFRQWLQXHG +6394291&6$ERXWYHQW/RJJLQJ YHQW/RJJLQJ3URFHGXUHV9LHZLQJWKHYHQW/RJ 7HVWLQJWKH6\VWHP7R%H&RQGXFWHGHHNO\ $ERXW7HVWLQJWKH6\VWHPCheck and Battery Displays 7URXEOH&RQGLWLRQVRcvr Jam 7URXEOH&RQGLWLRQV&RQWLQXHGOr Check Busy-Standby Long Rng TrblReplacing Batteries Wireless Sensors 0DLQWDLQLQJRXU6\VWHPLUH$ODUP6\VWHP,I,QVWDOOHG This Section Applies only to Residential SystemsEmergency Individual Keys LUH$ODUP6\VWHP&RQWLQXHGKey Pairs Ktchn Garage Lvng RM PHUJHQF\YDFXDWLRQ Function Procedure Comments 4XLFN*XLGHWR%DVLF6\VWHPXQFWLRQV6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV LHGRUGLVSOD\.H\SDGV6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV 5HJXODWRU\6WDWHPHQWVDQGDUQLQJV Federal Communications Commission FCC PartIndustry Canada FCC Part5HJXODWRU\6WDWHPHQWV&RQWLQXHG Industrie CanadaKDUWVRIRXU6\VWHP·VHDWXUHV Function Keys CommentsKDUWVRIRXU6\VWHP·VHDWXUHV KDUWVRIRXU6\VWHP·VHDWXUHV Partition 2 masterList of Output Devices $7,21627+,66670 Page ¬.-l
Related manuals
Manual 16 pages 12.41 Kb Manual 16 pages 23.09 Kb

FA168C-CN, FA148CP, FA168C, FA148CP-CN specifications

The First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP are standout models in the realm of fire alarm technology, presenting an effective blend of advanced features, reliable performance, and user-friendly design.

A hallmark of these models is their dual-sensor technology, which combines both photoelectric and ionization sensors. This innovative approach allows for quicker detection of a wide range of fire types, from smoldering fires that typically produce more smoke to fast-flaming fires that generate more heat. This dual capability enhances the efficiency and response time of the alarm, ensuring users receive timely alerts.

Another prominent characteristic of these First Alert models is their comprehensive connectivity. Most models are equipped with a wireless interconnect feature, which allows multiple alarms throughout the home to communicate with one another. When one unit detects smoke or carbon monoxide, all interconnected alarms will sound, maximizing alertness across the property. This feature is particularly beneficial in larger homes or multi-story buildings, where sound may not travel freely.

The FA168 series also includes a built-in, non-replaceable lithium battery, providing up to 10 years of power. This design not only eliminates the need for constant battery replacements but also ensures that the unit remains functional for an extended period without hassle. A convenient low battery notification alerts users when it’s time to replace the entire unit, adding an extra layer of safety.

In terms of installation, these models offer a user-friendly design that makes setup and maintenance straightforward. The unit typically features a single test/silence button, allowing users to quickly test the alarm's functionality or silence false alarms with ease.

Furthermore, the clear LED indicators provide visual confirmation of the alarm status, keeping users informed about potential threats. Design-wise, the FA168 series models boast a sleek and modern aesthetic that can seamlessly blend into various interior environments.

Overall, the First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP serve as reliable guardians against fire hazards, employing cutting-edge technology to offer peace of mind to users. With their formidable features, easy installation, and efficient power management, these fire alarm models stand as excellent choices for both homes and businesses seeking enhanced safety measures.