First Alert FA168C-CN, FA148CP-CN manual $ERXW7KH.H\SDGV&RQWLQXHG

Page 9

$ERXW￿7KH￿.H\SDGV￿￿&RQWLQXHG￿

)L[HG￿:RUG￿'LVSOD\￿.H\SDG

AWAY: All burglary zones, interior and perimeter, are armed.

STAY: Perimeter burglary zones, such as protected windows and doors, are armed.

INSTANT: Entry delay is turned off:

Lit with STAY = Instant mode Lit with AWAY = Maximum mode

 

 

 

AWAY

NIGHT NO AC

 

 

 

 

 

 

 

BYPASS

PHONE TEST

 

 

 

NOT READY

 

 

 

STAY

ALARM

 

 

CHIME BAT

FIRE

CHECK INSTANT

CANCELED

6150disp

TYPICAL FIXED-WORD DISPLAY

(FA260KP shown)

BYPASS: This appears when one or more burglary protection zones have been bypassed.

NOT READY: Appears when burglary portion of the system is not ready for arming (due to open protection zones). The system is ready to arm when this message disappears and the READY indicator light comes on.

NO AC: Appears when AC power has been cut off. System is operating on backup battery power.

AC: Appears when AC power is present.

CHIME: Appears when the CHIME feature is activated.

BAT: Low battery condition in a wireless sensor (if zone number displayed) or low system battery (if no zone number displayed).

ALARM: Appears when an intrusion has been detected and the system is armed (also appears during a fire alarm or audible emergency alarm). Accompanied by the protection zone in alarm.

CHECK: Appears when a malfunction is discovered in the system at any time or if an open is detected in a FIRE zone at any time or a fault in a DAY/NIGHT burglary zone during a disarmed period. Accompanied by a display of zone number in trouble.

FIRE : Appears when a fire alarm is present. Accompanied by a display of the zone in alarm.

A FIRE display also appears when a fire alarm is manually activated, accompanied by a display of emergency key zone number programmed for fire.

– 9 –

Image 9
Contents 8VHU·V*XLGH $ERXW7KLV0DQXDO 7DEOHRI&RQWHQWV Event Logging Procedures Using Device Commands Paging FeatureMacro Key Programming & Usage Security Codes & Authority Levels\VWHP2YHUYLHZ Qwurgxfwlrq\VWHP%DVLFV Memory of Alarm Alarms\VWHP2YHUYLHZ&RQWLQXHG Zones and PartitionsFunction Keys Phone AccessHQHUDO,QIRUPDWLRQ $ERXW7KH.H\SDGV$ERXW7KH.H\SDGV&RQWLQXHG XQFWLRQVRIWKH.H\SDGV XQFWLRQVRIWKH.H\SDGV&RQWLQXHG Offmax Away Stay Instantready Code ChimeQWU\HOD\ QWU\LWHOD\VPartition Partition 2 FA168CQWU\LWHOD\V&RQWLQXHG KHFNLQJRU2SHQ=RQHVLW$ODUPV $UPLQJWKH6\VWHP Mode Press these keys… Keypad Confirms By… $UPLQJ&RPPDQGVQuick Arming 6LQJOH%XWWRQ$UPLQJ 6WHS$UPLQJHDWXUHKey First Press Second Press Third Press To arm in the Stay mode To arm in the Away mode8VLQJWKH.H\VZLWFK 8VLQJWKH.H\VZLWFK8VLQJWKH2@NH\ LVDUPLQJDQG6LOHQFLQJ$ODUPV\SDVVLQJ3URWHFWLRQ=RQHV To turn Chime Mode off To turn Chime Mode on\SDVVLQJ3URWHFWLRQ=RQHV KLPH0RGH6HWWLQJWKHDWHDQG7LPH 9LHZLQJWKH&XUUHQWDWHDQG7LPH3DQLF.H\V This Function Sends this signal With This Sounding…8VLQJ3DQLF.H\V To active a Panic Function$ERXW0DFUR.H\V 0DFUR.H\3URJUDPPLQJ8VDJH0DFUR.H\3URJUDPPLQJ8VDJHFRQW DPSOHRI0DFUR3URJUDPPLQJ8VLQJD3URJUDPPHG0DFUR.H\ $ERXWHYLFH&RPPDQGV 8VLQJHYLFH&RPPDQGVTo Activate Devices To Deactivate Devices$ERXW$XWRPDWLF3DJLQJ 3DJLQJHDWXUHDWFK.H\3DJLQJ 0DQXDO3DJLQJ6HFXULW\&RGHV$XWKRULW\/HYHOV $ERXW6HFXULW\&RGHV$XWKRULW\/HYHOHILQLWLRQV +RZWR$VVLJQ8VHU&RGHVDQG$WWULEXWHV $FFHVVLQJ2WKHU3DUWLWLRQV$ 272&RPPDQGDQG0XOWL3DUWLWLRQ$UPLQJ$ERXW$FFHVVLQJ3DUWLWLRQV 8VLQJWKH*R7R&RPPDQG 0XOWL3DUWLWLRQ$UPLQJ+ ∗ + partition number 0,1,2,3 RPPRQ=RQH2SHUDWLRQ 6FKHGXOLQJ $ERXW6FKHGXOLQJUHDWLQJ6FKHGXOHV +6394291&6 6FKHGXOLQJFRQWLQXHGYHQW/RJJLQJ3URFHGXUHV $ERXWYHQW/RJJLQJ9LHZLQJWKHYHQW/RJ $ERXW7HVWLQJWKH6\VWHP 7HVWLQJWKH6\VWHP7R%H&RQGXFWHGHHNO\7URXEOH&RQGLWLRQV Check and Battery Displays7URXEOH&RQGLWLRQV&RQWLQXHG Rcvr JamOr Check Long Rng Trbl Busy-Standby0DLQWDLQLQJRXU6\VWHP Replacing Batteries Wireless SensorsThis Section Applies only to Residential Systems LUH$ODUP6\VWHP,I,QVWDOOHGLUH$ODUP6\VWHP&RQWLQXHG Emergency Individual KeysKey Pairs Ktchn Garage Lvng RM PHUJHQF\YDFXDWLRQ 4XLFN*XLGHWR%DVLF6\VWHPXQFWLRQV Function Procedure CommentsLHGRUGLVSOD\.H\SDGV 6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV6XPPDU\RI$XGLEOH9LVXDO1RWLILFDWLRQV Federal Communications Commission FCC Part 5HJXODWRU\6WDWHPHQWVDQGDUQLQJVIndustry Canada FCC PartIndustrie Canada 5HJXODWRU\6WDWHPHQWV&RQWLQXHGFunction Keys Comments KDUWVRIRXU6\VWHP·VHDWXUHVKDUWVRIRXU6\VWHP·VHDWXUHV Partition 2 master KDUWVRIRXU6\VWHP·VHDWXUHVList of Output Devices $7,21627+,66670 Page ¬.-l
Related manuals
Manual 16 pages 12.41 Kb Manual 16 pages 23.09 Kb

FA168C-CN, FA148CP, FA168C, FA148CP-CN specifications

The First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP are standout models in the realm of fire alarm technology, presenting an effective blend of advanced features, reliable performance, and user-friendly design.

A hallmark of these models is their dual-sensor technology, which combines both photoelectric and ionization sensors. This innovative approach allows for quicker detection of a wide range of fire types, from smoldering fires that typically produce more smoke to fast-flaming fires that generate more heat. This dual capability enhances the efficiency and response time of the alarm, ensuring users receive timely alerts.

Another prominent characteristic of these First Alert models is their comprehensive connectivity. Most models are equipped with a wireless interconnect feature, which allows multiple alarms throughout the home to communicate with one another. When one unit detects smoke or carbon monoxide, all interconnected alarms will sound, maximizing alertness across the property. This feature is particularly beneficial in larger homes or multi-story buildings, where sound may not travel freely.

The FA168 series also includes a built-in, non-replaceable lithium battery, providing up to 10 years of power. This design not only eliminates the need for constant battery replacements but also ensures that the unit remains functional for an extended period without hassle. A convenient low battery notification alerts users when it’s time to replace the entire unit, adding an extra layer of safety.

In terms of installation, these models offer a user-friendly design that makes setup and maintenance straightforward. The unit typically features a single test/silence button, allowing users to quickly test the alarm's functionality or silence false alarms with ease.

Furthermore, the clear LED indicators provide visual confirmation of the alarm status, keeping users informed about potential threats. Design-wise, the FA168 series models boast a sleek and modern aesthetic that can seamlessly blend into various interior environments.

Overall, the First Alert FA168CP-CN, FA168C-CN, FA168C, and FA168CP serve as reliable guardians against fire hazards, employing cutting-edge technology to offer peace of mind to users. With their formidable features, easy installation, and efficient power management, these fire alarm models stand as excellent choices for both homes and businesses seeking enhanced safety measures.