Using the ÊÊ5ÊÊ TEST Key

NO ALARM REPORTS WILL BE SENT TO THE CENTRAL MONITORING STATION while the system is in Test mode.

TESTING THE SYSTEM

TO BE CONDUCTED WEEKLY

The TEST key puts your system into Test mode, which allows each pro- tection point to be checked for proper operation.

1.Disarm the system and close all protected windows, doors, etc. The keypad's READY message should be displayed and the READY indicator (if present) should be lit.

2.Enter your security code and press the TEST key.

3.The keypad will sound a single beep every 40 seconds as a reminder that the system is in the test mode.

Each time a protection zone is faulted, the external siren or bell should sound for one second and then turn off, while the keypad sounds 3 beeps. If this does not happen, call for service immediately.

4.Open and close each protected door and window in turn and listen for the required sounds The identification of each faulted protection point should appear on the display.

5.Walk in front of any interior motion detectors (if used) and listen for the required sound as movement is detected. The identification of the detector should appear on the display when it is activated.

Note: Wireless PIR (Passive Infrared) units will send signals out only if they have been inactive for 3 minutes.

Ð 2 4 Ð

Image 24
Contents Users Manual Table of Contents Using Keyswitch Fire Alarm SYSTEM, if InstalledPanic Keys Trouble ConditionsSystem Overview System About the Keypads Keypad StylesFA250KP Summary of System Status Displays Not ReadySummary of Keypad Functions Armed Indicator RED Internal SounderSecurity Codes General Duress CodeQuick Arming To Assign, Change Or Delete User Codes ENTRY/EXIT Delays Using the Ready Key Checking for Open ZonesUsing Bypassing Protection ZonesBypass Key LimitationQuick Bypass Acthe System can Bypassnow be Armed with Readyzones BypassedWith Entry Delay on Arming Perimeter onlyWith Entry Delay OFF Arming ALL Protection AwayUsing the ÊÊ4ÊÊ Maximum Key Disarming the System and Silencing Alarms When Safe to do SOUsing the Keyswitch Chime Mode Panic KeysTo Initiate a Panic Function AT ANY Time of DAY or Night Individual Panic Testing the System Using the ÊÊ5ÊÊ Test KeyTesting the System Check and Battery Displays Trouble ConditionsTrouble Conditions Call Your Service Company Fire Alarm System General Case Of Fire AlarmTypical Fire Emergency Display Fire Alarm System General Steps to Safety Emergency EvacuationQuick Guide to Alarm System Functions Function Procedure CommentsSummary of AUDIBLE/VISUAL Notifications Protection Zones List Protection Zone Descriptions6 Ð Owners Insurance Premium Credit Request General InformationSmoke Detector Locations Burglary Detecting Device LocationsAdditional Pertinent Information Canadian Department of Communications DOC Statement I SUL Notice This is a Grade a Residential System Event of Telephone Operational Problems Limitations of this Alarm System Servicing Information ONE Year Limited Warranty

FA120C specifications

The First Alert FA120C is an essential tool for home safety and security, serving as a reliable smoke and carbon monoxide detector. It is engineered to protect you and your loved ones from the dangers of smoke and deadly carbon monoxide fumes, which can be invisible and odorless. Beyond its core functionalities, the FA120C boasts features and technologies that enhance its effectiveness and user experience.

This model employs an advanced photoelectric sensing technology, which excels at detecting smoldering fires. Unlike traditional ionization detectors that may respond more slowly to certain types of smoke, the photoelectric sensor in the FA120C can quickly identify slow-burning fires, providing earlier alerts and potentially more crucial time for escape. Additionally, this model integrates a carbon monoxide sensor, ensuring that users are alerted to elevated CO levels in the environment. This dual capability makes it an efficient choice for comprehensive fire safety.

Another significant feature of the First Alert FA120C is its battery-operated design, which ensures that the unit remains functional, even during power outages. This portability allows for flexible placement throughout the home, including areas where wiring may be challenging. The device is designed with a convenient low battery chirp, a feature that alerts users when it’s time to replace the batteries, thereby ensuring continuous protection.

The compact and sleek design of the FA120C allows it to blend seamlessly into various home decors. It is easy to mount, whether on a wall or ceiling, and comes with mounting hardware included in the package. Maintenance is simple as well, with a single test/silence button for checking the unit's functionality and silencing false alarms.

Moreover, First Alert is a trusted brand in safety equipment, giving users confidence in the reliability of the FA120C. The detector also meets a range of industry standards and regulations, making it a certified choice for consumers looking for top-notch safety solutions.

In summary, the First Alert FA120C is a sophisticated smoke and carbon monoxide detector that combines advanced detection technologies with user-friendly features. It is a vital investment for anyone prioritizing safety in their home, offering peace of mind with its dependable performance.