First Alert FA120C Fire Alarm System, General Case Of Fire Alarm, Typical Fire Emergency Display

Page 29

General

In Case Of Fire Alarm

FIRE ALARM SYSTEM

IF INSTALLED

Your fire alarm system (if installed) is on 24 hours a day, for continuous protection. In the event of an emergency, the strategically located smoke and heat detectors will automatically send signals to your system, triggering a loud, interrupted sound from the keypad. An interrupted sound will also be produced by optional exterior sounders. A FIRE message will appear at your keypad and remain on until you silence the alarm.

1.Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad and manually initiate an alarm by pressing the panic key pair assigned as FIRE emergency (if programmed by the installer) as indicated on page 23.

2.Evacuate all occupants from the premises.

3.If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately.

4.If no flames or smoke are apparent, investigate the cause of the alarm. The zone number(s) of the zone(s) in an alarm condition will be displayed at the keypad.

TYPICAL FIRE EMERGENCY DISPLAY

05

ALARM FIRE

AC

READY

Ð 2 9 Ð

Image 29
Contents Users Manual Table of Contents Fire Alarm SYSTEM, if Installed Using KeyswitchPanic Keys Trouble ConditionsSystem Overview System FA250KP About the KeypadsKeypad Styles Not Ready Summary of System Status DisplaysSummary of Keypad Functions Internal Sounder Armed Indicator REDQuick Arming Security CodesGeneral Duress Code To Assign, Change Or Delete User Codes ENTRY/EXIT Delays Checking for Open Zones Using the Ready KeyBypassing Protection Zones UsingBypass Key LimitationActhe System can Bypassnow be Armed with Readyzones Bypassed Quick BypassArming Perimeter only With Entry Delay onWith Entry Delay OFF Away Arming ALL ProtectionUsing the ÊÊ4ÊÊ Maximum Key When Safe to do SO Disarming the System and Silencing AlarmsUsing the Keyswitch To Initiate a Panic Function AT ANY Time of DAY or Night Chime ModePanic Keys Individual Panic Using the ÊÊ5ÊÊ Test Key Testing the SystemTesting the System Trouble Conditions Check and Battery DisplaysTrouble Conditions Call Your Service Company Typical Fire Emergency Display Fire Alarm SystemGeneral Case Of Fire Alarm Fire Alarm System General Emergency Evacuation Steps to SafetyFunction Procedure Comments Quick Guide to Alarm System FunctionsSummary of AUDIBLE/VISUAL Notifications Protection Zone Descriptions Protection Zones List6 Ð General Information Owners Insurance Premium Credit RequestAdditional Pertinent Information Smoke Detector LocationsBurglary Detecting Device Locations I S Canadian Department of Communications DOC StatementUL Notice This is a Grade a Residential System Event of Telephone Operational Problems Limitations of this Alarm System Servicing Information ONE Year Limited Warranty

FA120C specifications

The First Alert FA120C is an essential tool for home safety and security, serving as a reliable smoke and carbon monoxide detector. It is engineered to protect you and your loved ones from the dangers of smoke and deadly carbon monoxide fumes, which can be invisible and odorless. Beyond its core functionalities, the FA120C boasts features and technologies that enhance its effectiveness and user experience.

This model employs an advanced photoelectric sensing technology, which excels at detecting smoldering fires. Unlike traditional ionization detectors that may respond more slowly to certain types of smoke, the photoelectric sensor in the FA120C can quickly identify slow-burning fires, providing earlier alerts and potentially more crucial time for escape. Additionally, this model integrates a carbon monoxide sensor, ensuring that users are alerted to elevated CO levels in the environment. This dual capability makes it an efficient choice for comprehensive fire safety.

Another significant feature of the First Alert FA120C is its battery-operated design, which ensures that the unit remains functional, even during power outages. This portability allows for flexible placement throughout the home, including areas where wiring may be challenging. The device is designed with a convenient low battery chirp, a feature that alerts users when it’s time to replace the batteries, thereby ensuring continuous protection.

The compact and sleek design of the FA120C allows it to blend seamlessly into various home decors. It is easy to mount, whether on a wall or ceiling, and comes with mounting hardware included in the package. Maintenance is simple as well, with a single test/silence button for checking the unit's functionality and silencing false alarms.

Moreover, First Alert is a trusted brand in safety equipment, giving users confidence in the reliability of the FA120C. The detector also meets a range of industry standards and regulations, making it a certified choice for consumers looking for top-notch safety solutions.

In summary, the First Alert FA120C is a sophisticated smoke and carbon monoxide detector that combines advanced detection technologies with user-friendly features. It is a vital investment for anyone prioritizing safety in their home, offering peace of mind with its dependable performance.