First Alert 4800 user manual PTZ Baud Rate

Page 43

DVR Settings

Model 4800 User's Manual

CAMERA CHANNEL

Select the camera (channel) number and click the arrow buttons to select channel 1, 2, 3, 4, or All.

PTZ PROTOCOL*

Select the PTZ device protocol, and make sure it is consistent with the protocol of the installed PTZ cameras (options include: Pelco-D, Pelco-P, Panasonic, Philips, Samsung, Tiandy, et.al.). The changes take effect when you save and exit the menu.

Note: Before changing PTZ protocols, select the correct channel (camera) number in the Camera Channel field.

PTZ BAUD RATE*

Select the PTZ device baud rate and make sure it is consistent with the baud rate of the installed PTZ cameras (options: 1200, 2400, 4800, or 9600 bps). The changes take effect when you save and exit the menu.

PTZ ID*

Select the PTZ device ID, and make sure it is consistent with the ID of the installed PTZ cameras. Choose a number from 0 to 255. Press the arrow buttons to select a value. The changes take effect when you save and exit the menu.

COLOR SETTING

Adjust camera color attributes (brightness, contrast, hue, and saturation) for the best image rendition. By default, the values are set at 8 (average value). Make adjustments depending on the conditions at the location where the camera is installed.

Press the >> button to display a full-screen image of the camera feed, with the four color characteristics listed.

* Cameras supplied with 4800 system are not equipped with PTZ feature.

Image 43
Contents Indoor/Outdoor Analog Wired Cameras and DVR Model Page Table of Contents Ddns Mobile Phone Support Technical Information Warranty 100 FCC Compliance Safety PrecautionsDisposal Product Features Check Package ContentsREC Product OverviewAlarm Remote Control Installing a Hard Disk Drive Setting Up Cameras Basic Hardware InstallationMounting a Camera Video BNC connector power connector Start UP Getting StartedMain Menu Status BAR Functions of the Tool Bar buttons are Tool BAR Menu Options Video Playback Getting Started Video Backup PTZ Control Option Preset Point Procedures Sequence Procedures Screen Layout Adjustment Channel Status Display System Configuration Menu DVR SettingsDVR Settings System Language Time Setting Password Setting Advanced Settings Authority Manage Record Video Channel Record Quality Select the record resolution options CIF, D1, and Half D1 PTZ ID VideoPTZ Baud Rate Motion Detection Mosaic Motion Handling Record Channel Name Settings NET Http Port Next Pppoe IP Ddns File Sharing DVR Settings Alarm Event Handling options are Select to send email checkbox when an alarm is triggered Alarm Zoom OUT Maintenance LOG View HDD Manage This field shows the current hardware version of the DVR Save Restore Defaults Enabling Download of AN Unsigned Activex Control Web Browser OperationWEB Browser Main Window WEB Browser Login ScreenWeb Browser Operation Tools BAR Web Browser Operation Channel Font Action Web Browser Operation Blue Serial Alarm Web Browser Operation User Web Browser Operation Device State Talkback Search Download Device LOG ALL Query Kinds All Exception Local Storage Screen View Buttons PTZ Control PanelCruise Windows Mobile Mobile Phone SupportChannel Symbian S60 3RD Phone Menu Buttons and Program Interface Server Address LG KS10 Symbian Supported Mobile PhonesNokia N73 To download the Apple iPhone program Apple IphoneMobile Phone Support Troubleshooting Troubleshooting Problem Solution DVR Technical InformationCamera Warranty Exclusions Product Limited WarrantyObtaining Service

4800 specifications

The First Alert 4800 is a highly regarded smoke and carbon monoxide detector known for its reliability and advanced features. It is designed to enhance the safety of homes and businesses by promptly detecting smoke and hazardous carbon monoxide gases, which can pose serious threats to life and property.

One of the key features of the First Alert 4800 is its dual-sensor technology. This innovative design combines both photoelectric and ionization sensors, allowing the device to effectively sense slow, smoldering fires as well as fast-flaming fires. This dual approach significantly improves the chances of early detection, giving occupants crucial time to react in case of a fire emergency.

Another standout characteristic of the First Alert 4800 is its ability to detect dangerous levels of carbon monoxide. Carbon monoxide is often dubbed the "silent killer" because it is odorless and colorless, making it difficult to detect without proper equipment. The First Alert 4800 continuously monitors the air for this toxic gas, providing a reliable alarm when CO levels rise beyond safe thresholds.

The design of the First Alert 4800 incorporates a sleek and modern aesthetic that fits seamlessly into various home decors. Its unobtrusive appearance does not compromise its functionality. Furthermore, the unit features a clear digital display that indicates the levels of smoke and carbon monoxide detected, providing users with immediate information about their environment.

Installation and maintenance of the First Alert 4800 are user-friendly. The device comes with an easily accessible battery compartment and features a low-battery alert system. This ensures minimal disruption, as users can quickly replace batteries when needed. The unit is also equipped with a test button that allows users to check the functionality of the alarm with a simple press.

Another noteworthy technology included in the First Alert 4800 is its voice alarm feature. In addition to the standard alarm sounds, the device provides a voice alert that specifies the type of danger detected, whether it's smoke or carbon monoxide. This feature helps users make informed decisions in emergencies, particularly in stressful situations.

In summary, the First Alert 4800 is a cutting-edge smoke and carbon monoxide detector that prioritizes safety through its dual-sensor technology, modern design, and user-friendly features. With its reliable performance and intelligent alerts, it offers peace of mind to homeowners and businesses alike, ensuring that occupants are protected from the dangers of fire and toxic gases.