JONES RESIDENCE
F R I 2 : 51 AM
1 2 3 4
SELECT keys

Display Events

User Code Level: Master or Standard.

Function: Allows you to review up to 16 past events that occurred on your system from any keypad. Once 16 events are stored, any new event causes the oldest event to be cleared.

The event display you'll see at the keypad is slightly different for each event type.

Using the Display Events Function

1.

Access the User Menu.

2.

Press the COMMAND key until DISPLAY EVENTS? displays.

 

Press any SELECT key.

When accessed, the Display Events option displays events recorded automatically by the system in the order of their occurrence. You can view the events starting from the oldest to the most recent.

POWER

ARMED

AB C

D E F

G H I

J K L

5

6

7

8

MN O

P Q R

S T U

V W X

9

0

 

COMMAND

Y Z

 

 

 

3. The keypad displays the oldest recorded event.

Use the COMMAND key to scroll down through the list of events. Use the ARROW key to scroll back up through the event displays. If you press the ARROW key when you first enter the Display Events, the keypad returns to the Status List.

While in Display Events, you can use

the COMMAND and ARROW keys to ARROW COMMAND go forward or backward through the list of recorded events. There are five event types recorded by the system:

Zone Bypass Event Displays

This displays the bypassing of system zones.

Zone Events - Records zone alarms, troubles, and restores to normal condition.

Zone Bypass Events - Records the bypassing of any zone. The zone number, zone name, and the user number of the person bypassing the zone is recorded.

Display

JONES RESIDENCE

6 BYPS 1 2

Description

Zone 6 bypassed by user 12. Press the SELECT key under the zone number to display the custom zone name programmed into the system.

Arming and Disarming - Records arming and disarming of the system by user number and the areas armed or disarmed.

User Code Changes - Records addition, deletion, and change of user codes. Also notes user number of person making the change.

System Monitors - Records any loss of AC power or low battery conditions on the system.

Bypass Event Types - There are 2 event types:

BYP - Bypass RST - Restore

Note: You may sometimes see the user as SWG. This is short for the Swinger Bypass feature that allows the system to automatically bypass a zone that faults more than 3 times while the system is armed. Your system may or may not have this feature.

User Menu

Image 21
Contents User’s Guide Area Systems Silencing an Alarm All/Perimeter and Home/Away SystemsTable of Contents Security Command Users GuideEmergency Evacuation Plans About Your Security System Security Command keypadParts of the System Test Your System WeeklySecurity Command Keypad Character Keypad User Options MenuSelect keys Special Security Command Messages Special Security Command TonesSystem Trouble or Service Required Understanding Security System Terms Central Station Monitoring Exit ErrorStatus Armed StatusArming Functions How your System OperatesSystem Ready/System Not Ready Keypad Displays All/Perimeter System ArmingBypass and Force arming Arming an All/Perimeter SystemDisarming During an Alarm All/Perimeter System DisarmingDisarming an All/Perimeter System Arming a Home/Away System Home/Away System ArmingEasy Exit Feature Home/Away System DisarmingDisarming a Home/Away System Security Command User Menu Sensor ResetUser Checkin Outputs On Off Using the Bypass Zones FunctionBypass Zones Turning the Outputs On and OffZone Monitor Using the Zone Monitor FunctionSystem Test Using the System Test FunctionUser Codes 10 3812MasterUser Code Authority Levels Ambush CodesAdding User Code Numbers System Options Standard MasterChanging User Code Numbers Deleting User Code NumbersDisplay Events Using the Display Events FunctionZone Bypass Event Displays DisplayZone Event Displays Arming and Disarming Event DisplaysDisplay Description User Code Change Event Displays Request for ServiceUser Checkin Event Displays System Monitor Event DisplaysSystem Setup Security Command keypadsOutputs Area Name Pager Direct Users GuideAccount Number Message IDZone, Area, or User Number Page Digital Monitoring Products
Related manuals
Manual 26 pages 5.81 Kb

XR6, XR10 specifications

DMP Electronics has set a new standard in the audio industry with the introduction of the XR6 and XR10 models. These innovative devices cater to both audiophiles and casual listeners, providing unparalleled sound quality, robust features, and cutting-edge technology that enhance the listening experience.

The XR6 is designed with a compact form factor, making it perfect for smaller spaces without compromising on audio quality. It boasts a powerful 60-watt RMS output, ensuring clear and dynamic sound reproduction across various music genres. Its advanced acoustic design features a dual-driver configuration that delivers rich mids and crisp highs, creating an immersive audio experience. The XR6 also includes Bluetooth connectivity, allowing users to stream music wirelessly from their smartphones, tablets, or other devices.

In contrast, the XR10 takes things a step further, incorporating a larger driver system that supports an impressive 100-watt RMS output. This model is ideal for larger rooms or outdoor settings where a more substantial sound performance is desired. Both models feature DMP’s proprietary SoundEnhance technology, which optimizes audio performance by analyzing and adjusting the sound output according to the room's acoustics. This unique feature ensures that users enjoy consistent audio quality, irrespective of their listening environment.

Another highlight of the XR series is the user-friendly interface. Both the XR6 and XR10 come equipped with a digital display and an intuitive control panel, allowing users to navigate settings easily. The inclusion of multiple input options, such as USB, RCA, and a 3.5mm aux input, ensures compatibility with a wide array of devices, making them versatile additions to any audio setup.

Durability is a key characteristic of the XR series, with the models equipped with a robust housing that minimizes vibration and enhances sound clarity. The sleek, modern design complements any décor, ensuring that the devices are not only functional but also aesthetically pleasing.

DMP Electronics has also focused on sustainability, with both the XR6 and XR10 designed to be energy efficient, reducing their environmental impact. In a time when conscious consumerism is on the rise, such features resonate with eco-friendly users seeking high-performance audio solutions.

In conclusion, the DMP Electronics XR6 and XR10 are impressive additions to the audio market, combining high-quality sound, innovative technology, and user-friendly design. Whether for casual listening or serious audiophile use, these models promise to elevate the audio experience to new heights.