Kenmore I 53.329862 80 GALLON, I53.329562 55 GALLON Fire Hazard Electric Shock Hazard

Page 21

8.Clean the area around the element opening. Remove any sediment from or around the element opening, inside the tank.

g.If you are cleaning the element you have removed, do so by scraping or soaking in vinegar or a de-liming solution.

E

Fire Hazard and

Electric Shock Hazard

"Do not use replacement elements with any voltage other than shown on the model rating plate.

"Failure to use the correct voltage shown on the model rating plate could result in death, serious bodily injury, or property damage.

Replacement elements must (1) be the same voltage and (2) no greater wattage than listed on the model rating plate affixed to the water heater.

10.A new gasket should be used in all cases to prevent a possible water leak. (See Element Gasket in the "Repair Parts List " Chart). Place the new element gasket on the thread side of the cleaned or new element and screw into tank, securing tightly using an element wrench.

FIGURE 37.

11.Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front of the water heater.

12.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

13.To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the

water heater and the piping.

improper installation and use may result

in property damage.

. Fill tank with water before operation.

Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating element, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" power.

14.Check element for water leaks. If leakage occurs, tighten

element or repeat steps 2 and 3, remove element and reposition gasket. Then repeat steps 10 through 14.

15.Reconnect the two wires to the element and then check to

make sure the thermostat remains firmly against the surface of the tank.

FIGURE 38.

16. Replace terminal cover on thermostat making sure that the locking tabs on the terminal cover are in place.

LIFT OUT TAB TO UNCLIP

TERMINAL COVER

FROM THERMOSTAT

(

LOWER THERMOSTAT

WITHOUT HIGH LIMIT

UPPER AND LOWER

THERMOSTAT WITH

HiGH LiMiT

FIGURE 39.

17.Replace the insulation cap with handle so that it completely covers the thermostat and element.

iIQ -1

FIGURE 40.

21

Image 21
Contents Troubleshooting Parts List OperationSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Important Definitions Fire Hazard / Electric Shock Hazard Explosion HazardRepair Parts List Maximum Fuse TankMinimum GALS,PER HourTools Needed When Sweat Basic ToolsSoldering Removing the Old Water Heater Insulation Blankets Facts to Consider About the LocationFacts to Consider About Convertible Lower Element Property Damage HazardWater Piping Wate R H EaterElectric Listed Valve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Water Damage HazardAIR GAP Convertible Lower Element section Converting the Lower ElementFire and E×plosion Hazard Fire and Explosion HazardTerminal Cover from ThermostatWiring Green WiringDiagramsseeWiring Diagrams section have beenWiring Diagrams Temperature Settings Temperature RegulationUpper and Lower Thermostat Adjustments Adjustable Upper ThermostatTemperaturepressure Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingThermostat Removal/Replacement Element Cleaning/ReplacementUpper and Lower Thermostat with High Limit Upper and Lower Thermostat with High Limit Lift OUT TAB to Unclip Terminal Cover From Thermostat Fire Hazard Electric Shock HazardDrain Valve Washer Replacement ServiceWasher Operational Conditions ChartStart Up Conditions ExpansionFlammable hydrogen gases may be present CorrosionprotectiveactionoftheanodeMake sure the electrical supply to your water heater is on Shut off system. See High Temperature Shut Off SystemMakesuretheelectricsupplyhasbeenturnedOFF,andnever TheelementmaybeleakingatthetankfittingKey 153.329264I 38GallonShortI153.329462 153.329363153.329463 153.3295623 4 5 6 Kenmore Power Mber TM Electric Water HeatersPage Page Masterprotectionagreements Year Limited Warranty on Water Heater