Kenmore 153.326662 50 GAL, 326863 50 GAL owner manual Maximum Fuse, Minimum, Model, Gals.Per, Lower

Page 5

ThankYouforpurchasingSearswaterheaterProperly. installedandmaintained,it shouldgiveyouyearsoftrouble freeserviceItisstronglysuggestedthatthisnewwaterheater. beprofessionallyinstalled,contactthelocalSearsService CenteroranySearsstoreTheywillarrangeforprompt,quality. installationbySearsauthorizedcontractors.

Abbreviations Found In This Instruction Manual:

UL - Underwriters Laboratories Inc.

NEC - National Electrical Code

ANSI -American National Standards Institute

Read the "General Safety" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation,

operation, and maintenance of this electric water heater. It also contains warnings throughout the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few

pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with the instructions in this manual; electric company rules; and Local Codes, or in the

absence of Local Codes, with the current edition of the NEC - National Electrical Code, NFPA 70. This publication

is available from your local government or public library or

electric company or by writing Underwriters Laboratories

Inc., 333 Pfingsten Road, Northbrook, IL 60062.

If after reading this manual you have any questions or do

not understand any portion of the instructions, call Sears Service Center.

Carefully plan the place where you are going to put the water

heater. Correct electrical wiring and connections are very important in preventing death from possible electrical shock and fires.

Examine the location to ensure the water heater complies with the "Facts to Consider About the Location" section.

For California installation this water heater must be braced,

anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures.

Instructions may be obtained from the California Office of the

State Architect, 400 P Street, Sacramento, CA 95814.

Massachusetts Code requires this water heater to be installed

in accordance with Massachusetts 248-CMR 2.00; State

Plumbing Code and 248-CMR 5.00. In the Commonwealth of

Massachusetts, this product must be installed by a licensed plumber or gasfitter.

 

 

 

DIMENSIONS

 

 

 

ELEMENT

 

MAXIMUM FUSE

 

TANK

 

 

RECOVERY

RATE

WATTAGE

MINIMUM

OR CIRCUIT

 

IN INCHES (mm)

MODEL

CAPACITY

GALS.PER

HOUR

@240

VOLTS

WIRE SIZE*

BREAKER

 

 

 

 

NUMBER

IN GALLONS

DIA.

HEIGHT

,@_90°FRise

UPPER

LOWER

{GAUGE)

SIZE (AMPS)

 

 

 

 

 

 

153.326362

3O

I8.0

(457)

46.5

(I181)

17.3

 

3800

3800

12

2O

153.326363

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

153.326462

4O

I8.0

(457)

59.5

(1511)

17.3

 

3800

3800

12

2O

153.326463

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

153.326562

55

20.5

(521)

60.25

(I530)

17.3

 

3800

3800

12

2O

153.326563

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

153.326662

50

23.0

(584)

49.0

(1245)

17.3

 

3800

3800

12

2O

153.326663

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

153.326762

4O

20.5

(521)

44.0

(II18)

17.3

 

3800

3800

12

2O

153.326763

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

153.326862

50

26.5

(673)

34.0

(864)

17.3

 

3800

3800

12

2O

153.326863

25.0

 

3800

5500

10

3O

 

 

 

 

 

 

 

 

*Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.

Image 5
Contents Printed Operation Care and Maintenance Troubleshooting Parts ListSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Important Definitions Fire Hazard / Electric Shock Hazard Explosion HazardServiceandadjustment Installation InstructionsTroubleshooting Repair Parts ListMinimum Maximum FuseModel GALS.PERBasic Tools Additional Tools Needed When Sweat SolderingThreaded or Copper Plumbing Diameter for WaterRemoving the Old Water Heater Insulation Blankets Facts to Consider About the LocationFacts to Consider About Convertible Lower Element Property Damage HazardElectric Listed Water PipingWate R H Eater Valve Pressure ReliefPipe Do not Plug or CAF Floor DrainWater Damage Hazard DischargecapacityofthevalveFilling the Water Heater Electric Converting the Lower ElementConversion Parts Buss BAR Fire and E×plosion Hazard Tightenterminals2 and3 to ensureproperelectrical connectionLift OUT Tabto Unclip Terminal Plastic Tabs onWiring ReplacetheaccesspanelGreen WiringDiagramsseeWiring Diagrams section have beenSw,TCB 40-11 tt Wiring DiagramsLIMITl O1Ibl BOX RC=====.,vt=Upper and Lower Thermostat Adjustments Temperature RegulationTemperature Settings Draining Anode Rod InspectionBurn hazard Hotwater dischargeUpper and Lower Thermostat with High Limit Thermostat Removal/ReplacementElement Cleaning/Replacement Upper and Lower Thermostat with High Limit Lift OUT TAB to Unclip Terminal Cover From Thermostat Fire Hazard Electric Shock HazardWasher Drain Valve Washer ReplacementService Start Up Conditions ChartOperational Conditions Corrosionprotectiveactionoftheanode ResetWater is TOO HOT Make sure the electrical supply to your water heater is onWater TheelementmaybeleakingatthetankfittingCentertocheckthewaterheater MakesuretheelectricsupplyhasbeenturnedOFF,andneverKenmore Power Miser TM Electric Water Heaters Repair PARTS, Always Give When OrderingElement Ordering Information Following InformationModel No, 153,325862 @ @Page Page Warranty Service Year Exclusive Kenmore Labor WarrantySears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Masterprotectionagreements

153.326763 40 GAL, 153.326463 40 GAL, 153.326562 55 GAL, 153.326462 40 GA!, 326862 50 GAL specifications

The Kenmore water heaters, particularly models 153.326763, 153.326463, 153.326762, 153.326362, and 153.326462, have gained recognition for their efficiency, durability, and advanced technologies, catering to varying household needs with their different capacities.

The 40-gallon models, such as the 153.326763 and 153.326463, are ideal for larger families or homes with increased hot water demands. These models are designed to provide a continuous supply of hot water, making them suitable for simultaneous usage in multiple fixtures. The inclusion of energy-efficient features helps to keep operational costs low while maintaining reliable performance.

The 153.326762, another 40-gallon variant, boasts advanced insulation technology that minimizes heat loss, allowing the heater to maintain water temperature without excessive energy consumption. This model is built with a user-friendly interface, allowing for easy temperature adjustments and monitoring.

On the other hand, the 153.326362, a 30-gallon model, caters to smaller households or situations where space is limited but still requires adequate hot water supply. Despite its smaller tank size, it maintains a robust design ensuring quick recovery rates and efficient heating.

The 153.326462, another 40-gallon variant, is equipped with smart technology that provides real-time diagnostics and alerts for maintenance needs, helping to prolong the lifespan of the unit. This feature reduces the risk of unexpected breakdowns, ensuring peace of mind for the homeowner.

All models include a protective anode rod designed to minimize tank corrosion, significantly extending the life of the heater. Moreover, the high-quality build of these units includes a glass-lined tank that enhances durability and resistance to rust and scaling.

Kenmore prioritizes safety in its designs, including features such as a temperature and pressure relief valve, ensuring safe operation. With solid customer support and warranties offered on these units, homeowners can invest in Kenmore’s water heaters with confidence. Overall, the Kenmore line of water heaters combines advanced technology, efficiency, and user-friendly features, making them a reliable choice for a variety of hot water needs.