Start Up Conditions

THERMAL EXPANSION

Water supply systems may, because of such events as high line

pressure, frequent cut-offs, the effects of water hammer _mong others, have installed devices such as pressure reducing valves,

check valves, back flow preventers, etc...to control these-types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (ther-

mal expansion) and closed systems do not allow for the expan- sion of heated water.

The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of

the water heater's temperature-pressure relief valve is reacfied, the

valve will relieve the excesspressure. The temperature-pressure

relief valve is not intended'for the constant relief of thermal

expansion. This is an unacceptable condition and must be cor- rected.

It is recommended that any devices installed which could create a dosed system have a by-pass and/or the system have an expan-

sion tank to relieve the pre_ure built by thermal expansion.

Thermal expansion tanks ar'e available from Sears stores and

through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for

assistance in controlling these situations.

HOT

COLD

WATERHEATER

 

COLDWATER

PRESSURE

 

 

 

 

, INLETFII-nNG

 

 

REDUCING

 

 

 

 

 

 

VALVEWITH

 

 

 

BY-PASS

(t)

EXPANSION

TANK

(z)

PRESSUREGAUGE

WATER

SHUTOFF

RECOMMENDED INSTALLATION

(VERTICAL MOUNTING)

WATER HEATER

FLOOR,CEIUNG

COLD WATER

lOb-n;ETC.

INLET FITTING

 

 

STRAPPING

Thermal Expansion Tank Specifications

Model

Tank Capacity

Dimensions

in Inches

Pipe Fitting

Number

In Gallons

Diameter

Length

On Tank

153.331020

2

8 inches

12_inches

_" Male

153.331050

5

11 inches

14_inches

_" Male

Expansion Tank

Sizing Chart

 

 

 

 

Inlet*

Water

Heater Capacity

(Gallons)

 

Water

 

 

 

 

 

Expansion

Pressure

30

40

50

66

82

 

Tank

40psi

2

2

2

5

5

Capacity

50psi

2

2

2

5

5

Needed

60psi

2

2

5

5

5

 

70psi

2

2

5

5

5

 

80psi

2

5

5

5

5

*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.

NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If me inlet water pressure is higher than 40 psi, the

expansion tank's air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.

0)

PRESSURE

REDUCING INLET COLD

VALVEWITH WATER

(I)BY-PASS SHUTOFF EXPANSION

(z)

PRESSUREGAUGE

ALTERN.A.TERECOMMENDED

INSTALLATION

(NC?PJZONTALMOUNTING)

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal

parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.

Condensation causes sizzling and popping with the burner area

during heating and cooling periods and should be considered

normal. See "Condensation" section.

23

Image 23
Contents Awarning For Your SafetyAN Odorant is Added to the GAS Used by this Water Heater What to do if YOU Smell GASIwarning Safety PrecautionsSafety Precautions Burner Contents Customer Responsibilities Product SpecificationsBasic Tools Materials and Basic Tools NeededMaterials Needed Removing the Old Water Heater Installation InstructionsFacts to Consider About Location Installation Instructions contdALL AIR from Outdoors see Figures Installation Instructions contdALL AIR from Inside Buildings Rs. Theseincludetheelder,children,the infirm,or physical Water PipingHotter Water can SCALD.Water heatersare intendedto Iraln unlessa 6 air gapisprovided,To preventbodilyinjury,haz BTU/Hr. rateHealthrisk or asphyxiation Filling the Water HeaterVenting IAWARNING1Be surevent pipeisproperly connectedto preventescapeof ContdVenting contd Gas PipingGAS Piping with ALL Black Iron Pipe to GAS Control GAS Piping with Flexible ConnectorSediment Trap Venting instructions Installation InstructionsInstallation Checklist ContdCheck for Leaks Operating InstructionsLighting Replaceouterdoorif removed Set the thermostatto lowest setting by turningOperating Instructions contd Hotter Watercan SCALDWater heatersare intendedto Temperature RegulationVenting System Inspection Service and AdjustmentBurner Cleaning Tank Sediment CleaningInformation Service and Adjustment contdAssembly Replacement Gas Control Valve & BurnerHousekeeping Service and Adjustment contdDrain Valve Washer Replacement Contact Sears Repair Services at 1-800-4-MY-HOMEThermal Expansion Troubleshooting GuideStart Up Conditions Smelly Water Start Up Conditions contdCondensation SMOKE/ODORWater is TOO HOT Troubleshooting Guide contdHigh Temperature Shut OFF System Not Enough or no HOT WaterLeakage Checkpoints Page Page Page Gal. High Altitude Gal. Short High AltitudeGal. Short 3O GalParts Order List contd 153.337514 50 Gal. High Altitude 153.337563 50 Gal Parts Order List contdModel Ratin Plate t O27O118 153.337463 40 Gal 153.337514 50 Gal. High Altitude153.337614 65 Gal. High Altitude 9000071153.337663 65 Gal 153.337763 50 Gal. High Recovery Restrictor Ring # Manual # Mag-Erad Manifold CoverImproperventing Warranty

153.337363, 153.337463, 153.337563, 153.337863, 153.337214 specifications

The Kenmore line of appliances has long been synonymous with reliability and performance. Among its popular products are the Kenmore models 153.337214, 153.337663, 153.337563, 153.337463, and 153.337863. Each of these models offers a set of features designed to enhance the user experience and provide superior functionality.

One of the defining characteristics of these Kenmore models is their advanced technology. These units integrate innovative features such as smart connectivity, allowing users to monitor and control their appliances remotely via smartphone apps. This integration not only provides convenience but also aids in energy management, helping users save on energy costs while ensuring that their appliances are operating at peak efficiency.

The design of the Kenmore models also emphasizes user-friendly interfaces. Many of the units come equipped with touch controls and LED displays, making them simple to operate and program. This intuitive design is coupled with features like delayed start options and multiple cooking modes, catering to the diverse needs of modern households.

In terms of performance, Kenmore's 153.337214, 153.337663, 153.337563, 153.337463, and 153.337863 models showcase impressive energy efficiency ratings. Each model is engineered to minimize power consumption while maintaining high levels of performance, making them an eco-friendly choice for savvy consumers. Furthermore, these appliances often include features such as self-cleaning capabilities and noise-reduction technologies, ensuring that they are not only effective but also considerate of the user's comfort.

Safety is another priority in the design of these models. They come equipped with features such as auto shut-off, child locks, and safety sensors to ensure peace of mind for families. This commitment to safety, combined with a reputation for durability, means that Kenmore appliances are a trusted choice for many households.

In summary, Kenmore models 153.337214, 153.337663, 153.337563, 153.337463, and 153.337863 represent the brand's dedication to quality, innovation, and user satisfaction. With advanced technology, user-friendly designs, energy efficiency, and safety features, these appliances are well equipped to meet the demands of contemporary living while providing a reliable solution for everyday household tasks. Whether for cooking, cleaning, or other chores, these models are a testament to Kenmore's legacy of excellence in home appliances.