Closed System/Thermal Expansion

As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty.

A properly sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Thermal expansion tanks are available from Sears stores and through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for assistance in controlling these situations. (For additional information, see the Troubleshooting Guide later in this manual.)

Temperature and Pressure Relief Valve

Explosion Hazard

Temperature-pressure relief valve must comply with ANSI Z21.22-CSA 4.4 and ASME code.

• Properly sized temperature- pressure relief valve must be installed in opening provided.

• Can result in overheating and excessive tank pressure.

• Can cause serious injury or death.

For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked “T & P RELIEF VALVE.” (See Figure 24). This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed equipment or materials as meeting the requirements for Relief Valves for Hot Water Supply Systems, ANSI Z21.22. The function of the temperature and pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater. The valve’s relief pressure must not exceed the working pressure of the water heater as stated on the rating plate.

IMPORTANT: Only a new temperature and pressure relief valve should be used with your water heater. Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater. Do not place any valve between the relief valve and the tank.

The Temperature & Pressure Relief Valve:

Must not be in contact with any electrical part.

Must be connected to an adequate discharge line.

Must not be rated higher than the working pressure shown on the rating plate of the water heater.

The Discharge Line:

Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line.

Must not be capped, blocked, plugged or contain any valve between the relief valve and the end of the discharge line.

Must terminate a maximum of six inches above a floor drain or external to the building. In cold climates, it is recommended that the discharge line be terminated at an adequate drain inside the building.

Must be capable of withstanding 250°F (121°C) without distortion.

Must be installed to allow complete drainage of both the valve and discharge line.

T&P Relief Valve and Pipe Insulation

1.

Locate the temperature and pressure relief valve on the water

 

heater (also known as a T&P relief valve). See Figure 25.

2.

Locate the slit running the length of the T&P relief valve

 

insulation.

3.

Spread the slit open and fit the insulation over the T&P relief

 

valve. See Figure 25. Apply gentle pressure to the insulation

 

to ensure that it is fully seated on the T&P Relief Valve. Once

 

seated, secure the insulation with duct tape, electrical tape,

 

or equivalent. IMPORTANT: The insulation and tape must not

 

block the discharge opening or hinder access to the manual

 

relief lever (Figure 25). Ensure a discharge pipe is installed

 

into the T&P valve discharge opening per the instructions in

 

this manual.

4.

Locate the hot water (outlet) & cold water (inlet) pipes to the

 

water heater.

5.

Locate the slit running the length of a section of pipe insulation.

6.

Spread the slit open and slip the insulation over the cold water

 

(inlet) pipe. Apply gentle pressure along the length of the

 

insulation to ensure that it is fully seated around the pipe. Also,

1” MINIMUM

METAL DRAIN PAN

DRAIN

TEMPERATURE AND PRESSURE (T&P) RELIEF VALVE (OPTIONAL TOP T&P RELIEF VALVE NOT SHOWN)

DISCHARGE PIPE

(DO NOT CAP OR PLUG)

DRAIN LINE 3/4” ID MINIMUM

6” MAXIMUM AIR GAP

 

ensure that the base of the insulation is flush with the water

 

heater. Once seated, secure the insulation with duct tape,

 

electrical tape, or equivalent.

7.

Repeat steps 5 and 6 for the hot water (outlet) pipe.

8.

Add additional sections of pipe insulation as needed.

T&P RELIEF VALVE INSULATION

MANUAL RELIEF

LEVER

T&P RELIEF

VALVE

T&P RELIEF VALVE

DRAIN LINE

FIGURE 24.

FIGURE 25.

22

Image 22
Contents Power Miser GAS Water Heater Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.ASafe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Hazard Table of Contents Troubleshooting Guide Product Warranty Year Limited Warranty on Water HeaterCustomer Responsibilities Important Information About This Water HeaterProduct Specifications Jacket TOPMaterials and Basic Tools Needed Materials NeededTypical Installation Vent Pipe Inner DoorInstallation Checklist Important Information about this Water HeaterInstallation Instructions Removing the Old Water HeaterLocation Requirements Site LocationClearances and Accessibility Insulation BlanketsGas Requirements Filling the Water HeaterGAS Supply Gas PipingGas Pressure Gas Pressure TestingLP Gas Only Unconfined Space Combustion AIR Supply & VentilationAll Air from Inside the Building All Air from Outdoors Louvers and GrillesVent Pipe System Draft Hood InstallationVent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionOperating Your Water Heater Lighting InstructionsBurner Flames Water Temperature RegulationChecking the Draft Emergency Shut Down110 Burner Cleaning Service and AdjustmentTank Sediment Cleaning Vent System Inspection Burner InspectionAnode Rod Inspection Temperature-Pressure Relief Valve OperationHousekeeping Draining and FlushingService Maintenance of Your Water Heater Replacing the Pilot/ Pilot Tube Assembly Cleaning the Combustion Chamber and Flame-arrestorReplacing the Manifold/Burner Assembly Piezoelectric Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat Testing the Igniter SystemFvir System Operational Checklist Removing the Gas ValveTroubleshooting Guide Start Up ConditionsOperational Conditions CondensationLeakage Checkpoints Troubleshooting Chart Problem Possible Causes Corrective ActionThermostat Fails to Pilot Light Troubleshooting Flowchart YESPage Parts Order List Model Numbers Key No. Part DescriptionPower Miser 6 GAS Water Heater Page Page Get it fixed, at your home or ours MY-HOME1-800-469-4663

153.336482, 153.336372, 153.336333, 153.336433, 153.336472 specifications

The Kenmore series 153.336433, 153.336382, 153.336472, 153.336333, and 153.336482 represents a collection of top-tier appliances engineered to enhance home convenience and efficiency. Each model in this lineup boasts unique features, technologies, and characteristics, catering to diverse consumer needs.

First, the aesthetic appeal of the Kenmore appliances is paramount. Available in various finishes, including sleek stainless steel and classic white, they blend seamlessly into any kitchen decor, adding a touch of sophistication. The ergonomic design allows for easy operation and maintenance, ensuring that each appliance serves not just as a tool, but as a design statement.

One of the standout features across the models is their energy efficiency. Equipped with advanced energy-saving technologies, these appliances significantly reduce electricity and water consumption without compromising performance. The Energy Star certification on many models means consumers can enjoy substantial savings on utility bills while contributing to environmental sustainability.

Another key characteristic is the innovation in cooking technology. Many models incorporate smart technology that enables remote control and monitoring via smartphone applications. Users can preheat ovens, adjust settings, and track cooking times from anywhere in the home, ensuring perfectly cooked meals with minimal hassle.

The series also includes versatile cooking settings that cater to various culinary styles. Features such as convection cooking, steam assist, and multi-cooking modes enable users to experiment with a wide range of recipes. The user-friendly interface makes it simple to select the desired cooking method, ensuring that even novice cooks can prepare gourmet dishes effortlessly.

Safety features are a priority in the Kenmore range, with options like automatic shut-off, child safety locks, and temperature controls designed to prevent accidents in the kitchen. These appliances are built with durability in mind, utilizing high-quality materials that promise longevity and reliability.

In summary, the Kenmore models 153.336433, 153.336382, 153.336472, 153.336333, and 153.336482 combine style, efficiency, and innovation to elevate everyday cooking experiences. With their standout features and commitment to quality, these appliances are set to remain a popular choice for homeowners seeking to enhance their culinary endeavors. Whether you're renovating your kitchen or simply upgrading existing appliances, the Kenmore series offers unmatched performance and reliability.