Kenmore 153.332.410 manual Housekeeping, Anode Rod Inspection, Draining and Flushing

Page 27

Housekeeping

Vacuum around base of water heater for dust, dirt, and lint on a regular basis.

Fire and Explosion Hazard

Do not obstruct combustion air openings at the bottom of the water heater.

Do not use or store flammable vapor products such as gasoline, solvents or adhesives in the same room or area near water heater or other appliance.

At least annually, check the base-ring filter and flame arrester for any dust, lint, or debris that may have accumulated. Clean as necessary.

Can cause serious injury or death.

AT LEAST ANNUALLY, A VISUAL INSPECTION SHOULD BE MADE OF THE BASE-RING FILTER AND FLAME ARRESTER. CLEAN IF LINT ACCUMULATIONS ARE NOTICED.

INSTALLED IN SUITABLE AREA: To ensure sufficient ventilation and combustion air supply, proper clearances from the water heater must be maintained. See “Installation Instructions.” Combustible materials such as clothing, cleaning materials, or flammable liquids, etc. must not be placed against or adjacent to the water heater because they could catch on fire.

Anode Rod Inspection

The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod deteriorates to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.

FIGURE 29B.

Anode deterioration depends on water conductivity, not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by calling the Sears Service Center for an authorized contractor. At a minimum, the anode(s) should be checked annually after the warranty period.

Temperature-Pressure Relief Valve Operation

The temperature-pressure relief valve must be manually operated at least once a year.

Burn hazard

Hot water discharge.

Keep clear of relief valve discharge outlet.

When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot. See Figure 30.

FIGURE 30.

If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the manual gas shut-off valve and the cold water inlet valve and call the Sears Service Center.

If the temperature-pressure relief valve on the appliance weeps or discharges periodically, this may be due to thermal expansion. You may have a check valve installed in the water line or a water meter with a check valve. Consult the Sears Service Center for further information. Do not plug the temperature-pressure relief valve.

Draining and Flushing

It is recommended that the tank be drained and flushed every 6 months to remove sediment which may build up during

27

Image 27
Contents Gas Water Heater Safety Precautions Safe INSTALLATION, USE and ServiceFire or Explosion Hazard Table of Contents Troubleshooting Guide Year Limited Warranty on Water Heater Product WarrantyImportant Information About This Water Heater Customer ResponsibilitiesProduct Specifications Materials Needed Materials and Basic Tools NeededVent Pipe Inner Door Typical InstallationImportant Information about this Water Heater Installation ChecklistRemoving the Old Water Heater Installation InstructionsSite Location Location RequirementsInsulation Blankets Clearances and AccessibilityGas Piping Filling the Water HeaterGAS Supply Gas RequirementsGas Pressure Testing Gas PressureLP Gas Only Combustion AIR Supply & Ventilation Unconfined SpaceAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Pipe Size Draft Hood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveLighting Instructions Operating Your Water HeaterEmergency Shut Down Water Temperature RegulationChecking the Draft Burner Flames110 Burner Inspection Service and AdjustmentBurner Cleaning Vent System InspectionDraining and Flushing Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionService Maintenance of Your Water Heater Cleaning the Combustion Chamber and Flame-arrestor Replacing the Pilot/ Pilot Tube AssemblyPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyRemoving the Gas Valve Testing the Igniter SystemFvir System Operational Checklist Removing and Replacing the Gas Control Valve/ThermostatStart Up Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Problem Possible Causes Corrective Action Troubleshooting ChartThermostat Fails to YES Pilot Light Troubleshooting FlowchartPage Part Description Parts Order ListKenmore 36 GAS Water Heater Model NumbersPage MY-HOME1-800-469-4663 Get it fixed, at your home or ours

153.332.410 specifications

The Kenmore 153.332.410 is a versatile and efficient appliance that has gained popularity among homeowners looking for both functionality and reliability. This model exemplifies the high standards that Kenmore is known for, contributing to a seamless laundry experience.

One of the standout features of the Kenmore 153.332.410 is its user-friendly design. The intuitive control panel makes it easy for users to select appropriate settings for a variety of fabrics and loads. With multiple wash cycles available, including delicate, normal, and heavy-duty, the appliance caters to a range of laundry needs, ensuring your clothes are treated with care.

Another key characteristic is the capacity of the drum. The generous space allows users to wash larger loads in one go, saving time and energy. This is particularly beneficial for families or individuals with substantial laundry needs, as it minimizes the number of cycles needed, making laundry days far more efficient.

In terms of technology, the Kenmore 153.332.410 incorporates advanced washing capabilities, including a powerful agitation system that ensures thorough cleaning. The appliance effectively removes tough stains while being gentle enough for delicate items. Additionally, it features a high-efficiency design that reduces water and energy consumption without compromising performance.

The steam cleaning feature is noteworthy, as it not only helps in removing stubborn stains but also reduces wrinkles in garments, making ironing less of a chore. This technology is favored by many users, as it simplifies post-laundry tasks. Noise reduction technology also adds to the appliance's appeal, allowing it to operate quietly in the background, which is particularly valuable for apartments or homes where laundry is done overnight.

Durability is another aspect where the Kenmore 153.332.410 excels. Built with high-quality materials, this model is designed to withstand the rigors of frequent use. Its robust construction provides peace of mind that the appliance will deliver performance for years to come.

In conclusion, the Kenmore 153.332.410 stands out in the competitive landscape of laundry appliances. With its user-friendly features, advanced technology, generous capacity, and durability, it offers a comprehensive solution for all laundry needs, making it a worthy investment for any household.