Kenmore 153.332.410 manual Insulation Blankets, Clearances and Accessibility

Page 14

IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. Due to the normal corrosive action of water, the tank will eventually leak after an extended period of time. Also any external plumbing leak, including those from improper installation, may cause early failure of the tank due to corrosion if not repaired. If the homeowner is uncomfortable with making the repair a qualified technician should be contacted. A suitable metal drain pan should be installed under the water heater as shown below, to help protect the property from damage which may occur from condensate formation or leaks in the piping connections or tank. The pan must limit the water level to a maximum depth of 1-3/4” and be two inches wider than the heater and piped to an adequate drain. NOTE: The pan must not restrict combustion air flow. Locate the water heater near a suitable indoor drain. Outside drains are subject to freezing temperatures which can obstruct the drain line. The piping should be at least 3/4” ID and pitched for proper drainage.

METAL

DRAIN

PAN

PIPED TO AN

ADEQUATE DRAIN

AT LEAST 2” GREATER THAN THE

DIAMETER OF THE WATER HEATER.

FIGURE 9.

Water heater life depends upon water quality, water usage, water temperature and the environment in which the water heater is installed. Water heaters are sometimes installed in locations where leakage may result in property damage, even with the use of a metal drain pan piped to a drain. However, unanticipated damage can be reduced or prevented by a leak detector or water shut-off device used in conjunction with a piped metal drain pan. These devices are available from some plumbing supply wholesalers and retailers, and detect and react to leakage in various ways:

Sensors mounted in the metal drain pan that trigger an alarm or turn off the incoming water to the water heater when water is detected.

Sensors mounted in the metal drain pan that turn off the water supply to the entire home when water is detected in the drain pan.

Water supply shut-off devices that activate based on the water pressure differential between the cold water and hot water pipes connected to the water heater.

Devices that will turn off the gas supply to a gas water heater while at the same time shutting off its water supply.

Insulation Blankets

Insulation blankets available to the general public for external

use on gas water heaters are not necessary with Kenmore products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Kenmore water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

WARNING

Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 1 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.

Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.

Do not cover the outer door, thermostat or temperature & pressure relief valve.

Do not allow insulation to come within 2” (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

Do obtain new warning and instruction labels from Sears for placement on the blanket directly over the existing labels.

Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow.

Clearances and Accessibility

NOTE: Minimum clearances from combustible surfaces are stated on the label adjacent to the gas control valve/thermostat of the water heater. The water heater is certified for installation on a combustible floor.

IMPORTANT: If installing over carpeting, the carpeting must be protected by a metal or wood panel beneath the water heater. The protective panel must extend beyond the full width and depth of the water heater by at least three inches (76.2mm) in any direction; or if in an alcove or closet installation, the entire floor must be covered by the panel.

Figure 10 may be used as a reference guide to locate the specific clearance locations. A minimum of 24 inches of front clearance should be provided for inspection and service.

14

Image 14
Contents Gas Water Heater Safe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Hazard Table of Contents Troubleshooting Guide Product Warranty Year Limited Warranty on Water HeaterCustomer Responsibilities Important Information About This Water HeaterProduct Specifications Materials and Basic Tools Needed Materials NeededTypical Installation Vent Pipe Inner DoorInstallation Checklist Important Information about this Water HeaterInstallation Instructions Removing the Old Water HeaterLocation Requirements Site LocationClearances and Accessibility Insulation BlanketsGas Requirements Filling the Water HeaterGAS Supply Gas PipingLP Gas Only Gas Pressure TestingGas Pressure All Air from Inside the Building Combustion AIR Supply & VentilationUnconfined Space All Air from Outdoors Louvers and GrillesVent Pipe System Draft Hood InstallationVent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionOperating Your Water Heater Lighting InstructionsBurner Flames Water Temperature RegulationChecking the Draft Emergency Shut Down110 Vent System Inspection Service and AdjustmentBurner Cleaning Burner InspectionAnode Rod Inspection Temperature-Pressure Relief Valve OperationHousekeeping Draining and FlushingService Maintenance of Your Water Heater Replacing the Pilot/ Pilot Tube Assembly Cleaning the Combustion Chamber and Flame-arrestorReplacing the Manifold/Burner Assembly Piezoelectric Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat Testing the Igniter SystemFvir System Operational Checklist Removing the Gas ValveTroubleshooting Guide Start Up ConditionsOperational Conditions CondensationLeakage Checkpoints Troubleshooting Chart Problem Possible Causes Corrective ActionThermostat Fails to Pilot Light Troubleshooting Flowchart YESPage Model Numbers Parts Order ListKenmore 36 GAS Water Heater Part DescriptionPage Get it fixed, at your home or ours MY-HOME1-800-469-4663

153.332.410 specifications

The Kenmore 153.332.410 is a versatile and efficient appliance that has gained popularity among homeowners looking for both functionality and reliability. This model exemplifies the high standards that Kenmore is known for, contributing to a seamless laundry experience.

One of the standout features of the Kenmore 153.332.410 is its user-friendly design. The intuitive control panel makes it easy for users to select appropriate settings for a variety of fabrics and loads. With multiple wash cycles available, including delicate, normal, and heavy-duty, the appliance caters to a range of laundry needs, ensuring your clothes are treated with care.

Another key characteristic is the capacity of the drum. The generous space allows users to wash larger loads in one go, saving time and energy. This is particularly beneficial for families or individuals with substantial laundry needs, as it minimizes the number of cycles needed, making laundry days far more efficient.

In terms of technology, the Kenmore 153.332.410 incorporates advanced washing capabilities, including a powerful agitation system that ensures thorough cleaning. The appliance effectively removes tough stains while being gentle enough for delicate items. Additionally, it features a high-efficiency design that reduces water and energy consumption without compromising performance.

The steam cleaning feature is noteworthy, as it not only helps in removing stubborn stains but also reduces wrinkles in garments, making ironing less of a chore. This technology is favored by many users, as it simplifies post-laundry tasks. Noise reduction technology also adds to the appliance's appeal, allowing it to operate quietly in the background, which is particularly valuable for apartments or homes where laundry is done overnight.

Durability is another aspect where the Kenmore 153.332.410 excels. Built with high-quality materials, this model is designed to withstand the rigors of frequent use. Its robust construction provides peace of mind that the appliance will deliver performance for years to come.

In conclusion, the Kenmore 153.332.410 stands out in the competitive landscape of laundry appliances. With its user-friendly features, advanced technology, generous capacity, and durability, it offers a comprehensive solution for all laundry needs, making it a worthy investment for any household.