Kenmore 153.31604 owner manual Water Piping

Page 9

Water Piping

HOTTER WATER CAN SCALD: Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Temperature Regulation” section in this manual.

See Figure 8 for mixing valve usage.

meter with a check valve, etc... in the cold water supply; means must be provided to control thermal expansion. Contact the local utility or Sears Service Center on how to control this situation.

NOTE: If using copper tubing, solder tubing to an adapter before attaching the adapter to the water connections. Do not solder the water supply lines directly to the connections. It will harm the fittings on the water heater.

NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di electric unions or couplings be installed on this water heater when connected to copper pipe.

1.Look at the side of the water heater. The hot water outlet is marked hot. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around the 3/4” threaded nipple. Using flexible connectors, connect the hot water pipe to the hot water outlet of the water heater.

2.Look at the side of the water heater. The cold water inlet is marked cold. Put two or three turns of teflon tape around the threaded end of the threaded-to-sweat coupling and around the 3/4” threaded nipple. Using flexible connectors, connect the cold water pipe to the cold water inlet of the water heater.

FIGURE 8.

Figure 9 shows the attachment of the water piping to the water heater. The water heater is equipped with 3/4” water connections.

If a water heater is installed in a closed water supply system; such as one having a back-flow preventer, check valve, water

FIGURE 9.

NOTE: Your water heater is insulated to minimize heat loss from the tank. Further reduction in heat loss can be accomplished by insulating the hot water lines from the water heater.

Image 9
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Safe INSTALLATION, USE and Service General Safety Introduction Table of ContentsGauge Size Amps Product SpecificationsSoft Solder Solder Flux Emery Cloth Wire Brushes Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Materials NeededRemoving the Old Water Heater Installation InstructionsInsulation Blankets Facts to Consider About the LocationWater Piping Optional Installation Instructions Temperature-Pressure Relief ValveValve and Pipe Insulation Filling the Water Heater Wiring Wiring DiagramsWiring Connections Temperature Regulation Service and AdjustmentThermostat Adjustment Temperature SettingsDraining Temperature-Pressure Relief Valve OperationElement Cleaning/Replacement Thermostat Removal/ReplacementPage Service Drain Valve Washer ReplacementContact Sears Repair Services at 1-800-4-MY-HOME Anode Rod InspectionStart Up Conditions TroubleshootingOperational Conditions Thermal ExpansionHigh Temperature Shut OFF System AIR in HOT Water FaucetsRumbling Noise Water is TOO HOT Not Enough or no HOT WaterLeakage Checkpoints Repair Parts List This is a Repair Parts LIST, not a Packing List19 20S 19.9 20T Description Thermostat w/4 Terminal Hi Limit Key Model Numbers Part DescriptionYear Exclusive Kenmore Labor Warranty Year Limited Warranty on Water HeaterWarranty Service Sears Installation Service

153.31604 specifications

The Kenmore 153.31604 is a versatile and efficient dehumidifier designed for residential use, making it an ideal solution for those seeking to maintain a comfortable indoor environment. With a sleek and compact body, this appliance integrates seamlessly into various spaces, from basements to living rooms, delivering exceptional performance without being an eyesore.

One of the main features of the Kenmore 153.31604 is its impressive moisture removal capacity. It can efficiently extract up to 50 pints of moisture from the air per day, making it particularly effective for areas that experience high humidity levels. This capability allows homeowners to combat mold, mildew, and allergens, promoting a healthier living environment.

Equipped with advanced technologies, the Kenmore 153.31604 boasts an adjustable humidistat that provides optimal humidity control. Users can set their desired humidity level, and the dehumidifier will automatically cycle on and off to maintain that setting, ensuring energy efficiency. This feature not only saves electricity but also prolongs the appliance's lifespan.

The Kenmore 153.31604 also features a continuous drainage option. For convenience, this allows users to connect a garden hose to the unit, enabling continuous water drainage without the need to frequently empty the water bucket. The 1.8-gallon removable water tank is user-friendly as well, designed with a transparent window so users can easily monitor water levels. An overflow protection system is in place to prevent spills, adding to the appliance’s ease of use.

Noise levels can be a concern with many household appliances, but the Kenmore 153.31604 operates quietly, making it suitable for use in bedrooms and other quiet spaces. The lightweight design enhances portability, allowing users to move the unit from room to room as needed.

In terms of energy efficiency, the Kenmore 153.31604 is Energy Star certified, ensuring that it meets specific energy efficiency guidelines set by the EPA. This certification helps users save on energy bills while reducing their environmental impact.

Overall, the Kenmore 153.31604 combines functionality, technology, and user-friendly features, making it a top choice for anyone looking to control indoor humidity effectively. Its robust performance, efficient operation, and thoughtful design make it a valuable addition to any home.