Cooper Bussmann 9752 manual Log Event Codes, Message Meaning

Page 20

4. Special Functions

3.Press ￿to toggle the display between the time and date of the event and the log report. Press 1 to see earlier events in the log. Press 3 to see more recent events.

4. Press to stop using the log.

Table 1. Log Event Codes

Message

Meaning

EEProm Fail

Internal error, contact Installer.

Codes Defaulted

The access codes have been reset to default values.

Clear Log

The system programming has been returned to default values.

System Startup

System was started (power applied).

System Tamper

Bell or bell wiring tamper.

System Tamp Rst

System tamper reset.

Lid Tamper

Control unit lid opened.

Lid Tamper Rst

Lid tamper reset

Sounder Tamper

Sounder lid opened.

Sounder Tamp Rst

Sounder tamper reset.

Unn On-Site

User nn (see next page) put system into programming mode.

Unn Off-Site

User nn (see next page) put system out of programming mode.

Unn Change

User nn (see next page) changed their user code.

Unn Delete

User nn (see next page) deleted their user code.

Unn L# Set

User nn (see next page) set Level #.

Unn L# UnSet

User nn (see next page) unset Level #.

U12 L# Set

Telecommand set Level #.

U12 L# UnSet

Telecommand unset Level #.

U13 L# Set

Keyswitch set Level #.

U13 L# UnSet

Keyswitch unset Level #.

System Rearmed

System auto rearmed.

Unn Znn Omit

User nn (see next page) omitted zone nn.

Unn Znn Unomit

User nn (see next page) re-instated zone nn.

Fire Znn Alarm

Fire alarm at zone nn.

Fire Znn Rstr

Fire alarm at zone nn restored.

Fire Znn Reset

Fire alarm at zone nn reset.

PA Znn Alarm

Panic alarm at zone nn.

PA Znn Rstr

Panic alarm at zone nn restored.

Unn System Unset

User nn (see next page) unset system.

PA Knn Alarm

Panic alarm started at keypad nn.

Burg Znn Alarm

Intruder alarm at zone nn.

Set Fail Znn

Setting failed because of zone nn.

Burg Znn Rstr

Intruder alarm at zone nn restored.

Tamper Znn

Tamper at zone nn.

Knn Missing

Keypad nn missing.

Knn Restore

Keypad nn restored.

Knn Tamper

Tamper at keypad nn.

Knn Excess Keys

Too many keys pressed at keypad nn (someone may be trying to

 

guess the access code).

Low Bat Znn

Radio detector nn has reported a low battery.

Low Bat Znn Rstr

Low battery report from zone nn restored.

RF Jamming

Radio jamming detected.

RF Jamming Rstr

Radio jamming stopped (restored).

RF Sup Fail Znn

Radio detector nn is not responding.

RF Sup Rstr Znn

Radio detector nn is responding again (restored).

20

496679

Image 20
Contents User Guide Contents Alarm System KeypadsKey Used to Introduction725r Telecommand Remote Setting Device About This GuideTimed Set Setting the SystemHow Do I Know if the System is Working? Exceeding the Exit Time Final Door SetUsing an Exit Terminate Button to Set the System Part SettingKeyswitch Setting Instant SetPage Press Starting Alarms Yourself System is now unset Unsetting From a 725r Full or Part SetSystem is now unset If You Exceed the Entry TimeDuress Code PTOReset the system yourself from the keypad Press Introduction Omitting ZonesAccess Codes Page C Æ Å Ä Log Event Codes Message MeaningSpecial Functions Page That you have triggered. If there is Company Name

9752 specifications

The Cooper Bussmann 9752 is a versatile and reliable fuse that plays a critical role in protecting electrical circuits against overloads and short circuits. This specific fuse is designed to cater to a wide range of applications, particularly in industrial, commercial, and residential settings. The 9752 model is renowned for its robust construction and operational efficiency, making it a go-to choice for many electrical engineers and technicians.

One of the most notable features of the Cooper Bussmann 9752 is its current limiting capability. This technology allows the fuse to reduce the amount of energy that can pass through when a fault occurs. By limiting the current, the 9752 effectively minimizes the potential for thermal damage to both the fuse itself and other components in the circuit, thereby ensuring greater system integrity.

The 9752 is constructed using high-quality materials that ensure durability and a long service life. Its design includes a reliable element that melts only under fault conditions, allowing normal operating currents to pass without interruption. This feature is particularly important in protecting sensitive electronic equipment from damage due to unexpected surges in current.

Another key characteristic of the Cooper Bussmann 9752 is its fast-acting response time. In emergency situations where time is of the essence, the 9752 quickly reacts to harmful overload conditions, disconnecting the circuit almost instantaneously. This quick action helps avoid extensive damage and safety risks, making it an essential component in critical applications.

The Cooper Bussmann 9752 fuse is also designed with user convenience in mind. Its compact size and standard mounting options allow for easy installation in a variety of electrical panels and enclosures. Additionally, the fuse’s clear labeling and identification features make it easy to determine its specifications and ratings, facilitating maintenance and replacement.

In conclusion, the Cooper Bussmann 9752 is an exemplary choice for circuit protection. With its current limiting technology, durable construction, fast-acting response, and user-friendly design, it meets the high standards demanded by modern electrical systems. Whether it's used in industrial machinery, commercial buildings, or residential applications, the 9752 fuse delivers reliable performance, ensuring the safety and longevity of connected devices and systems.