The SR-10K readers are designed to provide continuous service with minimal routine maintenance. However, contaminants (such as magnetic oxides from badges and dirt) tend to accumulate on the read head. Without regular cleaning, these contaminants will shorten the read head life and increase the probability of card read error. A maintenance schedule should be developed base on the card reader environment (dirty or clean) and the usage frequency (light traffic or heavy traffic). Extreme case may require daily cleaning.

Head cleaning may be done by using disposable, pre-saturated magnetic head cleaning card. These cards are readily obtainable from a number of sources (e.g. Clean Team Co. 800-888-8830, www.cleanteam.com; KIC Products, 207-514-7030, www.kicproducts.com; System ID, 1-888-648- 4452, www.systemid.com).

The reader exterior surface is covered with high strength polymer and polyester membrane. It may be cleaned with a soft cloth and mild detergent if required.

Specification:

The reader/Interface are for use in low voltage, class 2 circuits only.

Electrical:

Voltage -

12 Vdc (10.2 to 13.8 Vdc)

 

Current -

200mA

 

Relay contacts- K1, 5A@30Vdc; K2, 1A@30Vdc

 

Distance between reader/interface - 500' (152m) max., 22AWG

 

RS-485 Comm. Cable - 4,000' (1,219m) max. 24AWG, 120 ohm.

Mechanical:

Reader:

 

 

Dimension -

1.95" (50mm)W x 1.30" (33mm)H x 5.50" (140mm)L

 

Weight -

10 oz. (284 g) nominal

 

Interface:

 

 

Dimension -

3.25" (83mm)W x 2.9" (74mm)L x 1.4" (36mm)H

 

Weight -

4 oz. (120 g) nominal

Environmental:

Temperature:

-55 to +85 degrees C, storage

 

 

-40 to +75 degrees C, operating

 

Humidity:

Reader- 100% RHNC; Interface- 95% RHNC

WARRANTY

Mercury Security Corporation warrants that the product is free from defects in material and workmanship under normal use and service for two years from factory shipment. Mercury Security Corporation assumes no responsibility for products damaged by improper handling or installation. This warranty is limited to the repair or replacement of the defective unit.

There is no expressed warranties other than set forth herein. Mercury Security Corporation does not make, intends, nor does it authorize any agent or representative to make any other warranties, implied warranties, and expressly excludes and disclaims all implied warranties of merchantability of fitness for a particular purpose. Returned units are repaired or replaced from a stock of reconditioned units. Returns must be accompanied by a return authorization number obtained form customer service, a purchase order and prepaid postage.

LIABILITY

The card readers should only be used to control exits from areas where an alternate method for exit is available. This product is not intended for, nor is rated for operation in life-critical control applications. Mercury Security Corporation is not liable under any circumstances for loss or damage caused by or partially caused by the misapplication or malfunction of the product. Mercury Security Corporation's liability does not extend beyond the purchase price of the product.

Mercury Security Corporation, © 2005

SR-10K

Doc. 10107-0007 Rev 1.04

Page 17

Image 17
Contents SR-10K Mag-Stripe Access System Users Guide Table of Contents Card Database Options DescriptionProgramming User Levels Cipher CodesOperating Modes Multi-Reader SitesInterpreting the LED and Buzzer Indicators Configuration PlanningQuick Start Lost Master CardCommand 11 Delete a card, using the user slot Command 10 Add cardsCommand 12 Delete a card, using the card Command 13 Delete a range of cardsBlock Database Mode Commands Commands 20 through Cipher Codes Related Commands Commands 15 throughConfiguration and Database Copy Commands Commands 41through System Configuration Settings Commands 91through Configuration Operating Mode Access Control with Door MonitoringUser Level Specifications Description Operating Mode Access Control and Alarm Panel Control Description Operating Mode Two-Door Access Control Operating Mode Supervisor Restricted Access ControlOperating Mode Output Toggle on Valid Access Operating Mode Access Control with Door Buzzer ControlRelay Contact Protection/Noise Suppression InstallationSpecification MaintenanceStrike Addendum Revision C

SR-10K, SR-10K Mag-Stripe Access System specifications

The Mercury SR-10K Mag-Stripe Access System is a cutting-edge access control solution designed for environments that require robust security and reliable performance. This system is well-suited for various applications, including commercial buildings, educational institutions, and industrial facilities. With its advanced technology and user-friendly design, the SR-10K provides a comprehensive security platform that streamlines access management.

One of the main features of the SR-10K is its compatibility with both magnetic stripe cards and ISO 7810-compliant cards. This flexibility allows organizations to implement existing card technologies without the need for extensive infrastructure changes. The system supports both single-door and multi-door configurations, making it adaptable to different facility requirements.

The SR-10K includes a powerful embedded controller that ensures efficient processing of access control transactions. This controller leverages smart technology to manage access rights and monitor activities in real-time, providing operators with immediate insights into system status. Additionally, it incorporates a user-friendly interface, allowing for straightforward programming and administration of the access control system.

Durability is a key characteristic of the SR-10K, as it is designed to withstand the rigors of everyday use in demanding environments. The system features weather-resistant components, making it suitable for both indoor and outdoor installations. This robustness contributes to the overall reliability of the security solution, reducing maintenance and operational costs over time.

The SR-10K also integrates seamlessly with existing security infrastructures, supporting various communication protocols such as Wiegand and RS-485. This connectivity allows organizations to enhance their security measures by integrating the access control system with surveillance cameras, alarms, and other security devices. The SR-10K can be easily scaled to accommodate future growth, ensuring that the system remains effective as security needs evolve.

In addition to its technical features, the SR-10K prioritizes user experience. The system offers intuitive software for system management, which simplifies the process of managing user profiles, access permissions, and activity logs. This accessibility ensures that security personnel can effectively monitor and respond to access events.

Overall, the Mercury SR-10K Mag-Stripe Access System stands out as a versatile and reliable access control solution. Its combination of advanced features, robust construction, and ease of use makes it an ideal choice for organizations seeking to enhance their security while maintaining operational efficiency.