Mercury PR0091 manual Over-ride Operation, Thermostat Over-ride

Page 11

Mercury 6-5 Stat – Installation & User Guide

Over-ride Operation

The 5 Channel Thermostat can operate either from its internal channel time settings or from a network Data Manager GP Timer channel (P70 sets the mode either local or remote). If the 5 Channel Thermostat is set up to use the remote timing channels it reverts to local mode if network communications are lost for more than 5 minutes. An over-ride occurs when a resistor is switched in across the input which has to be overridden, however when the over-ride signal is removed the channel returns too normal operation.

Thermostat Over-ride: -

When a channel is configured for thermostat operation the following will occur when an over-ride is present on the channel input. In the example below channel 1 is set as a thermostat in a heating application, the relay inverse feature is disabled, the controller timer is set to local operation and is off. When the timer is in the off period the channel will not be enabled for heating and the thermostat relay remains off, providing the probe temperature is not below the frost detect set point. As shown in the diagram an over-ride is applied to channel 1, this will enable the channel. The thermostat relay does not immediately turn on, it only does so when the temperature drops below the cut-in set point. The controller will continue normal temperature control until the over-ride is removed or the next scheduled off occurs in the local timer schedule. When the timer is in the on period, the over-ride has no effect. Note:- An over-ride should be removed as soon as it is not required on an input.

Over-ride

Activated

 

Diff

 

 

Temperature

Cut-in Set

 

Relay State

Point

On

Frost

Off

 

Detect

 

 

 

 

Time

 

Thermostat Relay Status

Ch 1 Probe Temperature

Ensure that all power is

 

 

switched off before

 

 

installing or maintaining

 

 

this product

Revision 1.2

Page 11 of 21

Image 11
Contents Mercury Channel Thermostat Installation Guide Table of Contents Display value Type M Channel Thermostat Network ConfigurationFrom Resource Data Management DescriptionDo not connect an earth Input/Output Allocation Tables Ch Thermostat Description Alarm Action Switched ResistorConnections Set-up Function Menu Display Option Explained in Paragraph Setting up the controllerSet-up Mode Set-up through front buttons Type. view controller type Recommended set-up methodRevision Mercury 6-5 Stat Installation & User Guide Units and Probe Type Probe FaultIP-r Network ConfigurationIP Futura module Thermostat Over-ride Over-ride OperationInvert Channel TimerNormal Operation Frost DetectCooling Thermostat graph Heating Thermostat graph Thermostat Cooling/Heating OperationDisplay System status ViewingDisplay Messages GP Timer Set-up Network AlarmsAlarm text Type Relays Specification General Power requirementsInputs Clearances Panel Cut-outFixing Over-ride input Resistors WiringFuse CleaningRevision History

PR0091 specifications

Mercury PR0091 is a pioneering device that seamlessly integrates cutting-edge technologies to deliver exceptional performance and versatility across various applications. This innovative product has been designed with a strong focus on user experience, featuring advanced functionalities that cater to the evolving needs of users.

One of the standout features of the Mercury PR0091 is its robust processing capability. Equipped with a high-performance processor, it ensures swift operation and efficient multitasking. Whether used for professional tasks, creative endeavors, or entertainment, the device handles demanding applications with ease, providing users with a seamless experience.

Another significant characteristic of the Mercury PR0091 is its high-resolution display. The device boasts an impressive screen that delivers vibrant colors and sharp visuals, making it ideal for viewing high-definition content, graphics-intensive tasks, and engaging in immersive gaming experiences. Users can enjoy crystal-clear clarity, ensuring that every detail is vividly presented.

The connectivity options available on the Mercury PR0091 are extensive, including Wi-Fi, Bluetooth, and multiple USB ports. This ample connectivity ensures that users can easily link the device with other peripherals and systems, enhancing productivity and convenience. Whether connecting to external displays, storage devices, or other electronic gadgets, users will find that Mercury PR0091 is equipped to handle their networking needs.

In terms of design, the Mercury PR0091 showcases an elegant and ergonomic form factor that combines aesthetics with functionality. Its lightweight build makes it highly portable, making it suitable for on-the-go users who need reliable performance without the bulk. The sleek design also appeals to style-conscious consumers, embodying a modern and professional look.

Security features are also integral to the Mercury PR0091. With advanced encryption and biometric authentication, users can trust that their data is safe from unauthorized access. This is particularly relevant in today's digital landscape where data privacy is paramount.

Additionally, the Mercury PR0091 is built with sustainability in mind. Utilizing eco-friendly materials and energy-efficient technologies, it minimizes its environmental impact while still delivering top-notch performance.

In conclusion, the Mercury PR0091 is a versatile and powerful device equipped with a range of features and technologies that make it a standout choice for various applications. With its high-performance processing, superior display, extensive connectivity, elegant design, enhanced security, and commitment to sustainability, it meets and exceeds the diverse demands of modern users.