Nordyne R-410A user manual Motor Speed Air Flow, X24K, X36K, X48K, X60K, Motor Lead Connection

Page 10

 

Green

 

 

 

 

(from Blower Relay)

 

 

R

 

Y2 out

 

 

W2

Y

Y out

 

 

 

 

 

O

R

 

 

 

 

 

 

 

Y1

 

 

 

 

Y2

C

 

 

 

 

 

 

 

G

 

 

 

 

 

in

out

1

Brown

C

 

 

 

Y2

 

2

Orange

E

 

 

3

 

 

L

DF

4

 

L

5

 

 

 

DF2

6

 

 

 

7

 

 

 

 

 

INDOOR

 

 

8

 

 

DEFROST

9

 

THERMOSTAT

 

BOARD

Accessory Heat Plug

 

 

 

SUB-BASE

 

 

 

 

Figure 9. Typical Wiring (Field Supplied) for 2-Stage Cool, 2 Stage Electric Heat

Model Q5RF

Wire Color/Speed Tap

Motor Speed

Air Flow

(@ 0.3 in WC)

 

 

 

 

 

 

 

 

T1

Low

560

 

Orange/T2

Medium/Low*

600

 

 

 

 

X24K

Black/T3

Medium**

800

 

Red/T4

Medium/High***

1,040

 

 

 

 

 

T5

High

1,250

 

 

 

 

 

Orange/T1

Low*

600

 

 

 

 

 

T2

Medium/Low

750

 

 

 

 

X36K

Black/T3

Medium**

1,200

 

Red/T4

Medium/High***

1,420

 

 

 

 

 

T5

High

1,520

 

 

 

 

 

Orange/T1

Low*

1,030

 

 

 

 

 

T2

Medium/Low

1,240

X48K

Red/T3

Medium***

1,400

 

Black/T4

Medium/High**

1,530

 

 

 

 

 

T5

High

1,680

 

 

 

 

 

Orange/T1

Low

1,060

 

 

 

 

 

T2

Medium/Low*

1,200

X60K

 

 

 

Red/T3

Medium***

1,500

 

 

 

 

 

Black/T4

Medium/High**

1,760

 

 

 

 

 

T5

High

1,970

* Denotes Factory Set Low Speed Cooling/ Heating ** Denotes Factory Set High Speed Cooling/ Heating

*** Denotes Factory Set Electric Heating Speed

Table 2. Motor Lead Connection

10

Image 10
Contents USER’s Manual & Installation Instructions System Operation User Information Safety InformationAbout the Heat Pump General Information Warranty InformationPre-Installation Check Inspecting EquipmentUnit Under the Home Heat Pump InstallationCondensate Drainage Supply Duct Installing Return Supply AIR FittingsLocating and Installing Return AIR Assembly Return DuctLocating and Installing Supply Dampers Typical ApplicationsElectrical Connections Connecting the Return and Supply Air Flexible DuctsBlower Speed High VoltageLocating the Thermostat Low Pressure SwitchHigh Pressure Switch Speed Outdoor Fan Motor Select ModelsX36K Motor Speed Air FlowX24K X48KDiagnostic Description LED Status Control Diagnostic Ambient Sensor MountingStart-Up Procedure Pre-Start ChecklistDefrost Test Procedure Adjustment of Refrigerant Charge Anti Short Cycle Timer TestCharging an R-410A Unit in Heating Mode Refrigerant Charging Charts for Cooling Mode of Operation Charging Chart for 4 ton Units Refrigerant Charging Tables for Heating Mode of Operation Q5RF-X48K Wiring Diagram Ton UnitsQ5RF/PPH2RF Series Small Package H/P ¢709064-¤
Related manuals
Manual 24 pages 38.33 Kb Manual 20 pages 19.69 Kb

R-410A specifications

Nordyne R-410A is a widely recognized refrigerant used in modern air conditioning and heat pump systems, known for its efficiency and environmentally friendly attributes. As a hydrofluorocarbon (HFC) refrigerant, R-410A has become the preferred choice for many manufacturers seeking to meet stringent environmental regulations while providing superior cooling performance.

One of the main features of R-410A is its higher energy efficiency compared to older refrigerants like R-22. This efficiency is primarily attributed to its higher pressure capabilities, which allow for improved heat transfer and reduced energy consumption in residential and commercial systems. As energy costs continue to rise, the use of R-410A in HVAC systems offers a viable solution for reducing utility bills while maintaining optimal comfort levels.

R-410A is also non-ozone-depleting, which sets it apart from many traditional refrigerants. While older refrigerants have been phased out due to their potential harm to the ozone layer, R-410A presents a sustainable alternative that aligns with environmental goals. It features a zero ozone depletion potential (ODP), making it a responsible choice for installations concerned with ecological impact.

In terms of technology, R-410A works effectively in both air conditioning and heat pump systems, providing reliable cooling in hot conditions and heat in colder months. It is compatible with a variety of system designs and can excel in both residential and commercial applications. Moreover, the thermodynamic properties of R-410A ensure consistent and reliable performance, regardless of the external temperature fluctuations.

Another characteristic of R-410A is its ability to operate at lower temperatures, which enhances its versatility. This capability allows for the design of systems that can function efficiently in a wider range of climate conditions. As a result, HVAC technicians and contractors benefit from its reliability and performance, leading to less frequent maintenance and enhanced customer satisfaction.

Lastly, R-410A systems are equipped with advanced components that improve overall functionality. These systems often include variable-speed compressors, which optimize energy use based on cooling demand, and advanced refrigerant management technologies that ensure safe and efficient operation.

In conclusion, Nordyne R-410A stands out as a superior refrigerant due to its energy efficiency, environmental benefits, and adaptability across a range of HVAC applications. As the industry continues to innovate and shift toward sustainable solutions, R-410A remains at the forefront of refrigerant technology, ensuring homeowners and businesses alike enjoy efficient and eco-friendly cooling options.