SAFETY INFORMATION

IMPORTANT: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and any other special notes highlighted in the manual. Safety markings are used frequently throughout this manual to designate a degree or level of seriousness and should not be ignored. WARNING indicates a potentially hazardous situation that if not avoided, could result in personal injury or death.CAUTION indicates a potentially hazardous situation that if not avoided, may result in minor or moderate injury or property damage.

USER INFORMATION

About the Heat Pump

Your heat pump is a unique, all weather comfort- control appliance that will heat and cool your home year round and provide energy saving comfort. It’s an unknown fact that heat is always in the air, even when the outside temperature is below freezing. The heat pump uses this basic law of physics to provide energy saving heat during the winter months. For example, If the outdoor temperature is 47° F (8° C), your heat pump can deliver approximately 3.5 units of heat energy per each unit of electrical energy used, as compared to a maximum of only 1 unit of heat energy produced with conventional heating systems.

In colder temperatures, the heat pump performs like an air conditioner run in reverse. Available heat energy outside the home is absorbed by the refrigerant and exhausted inside the home. This efficient process means you only pay for“moving” the heat from the outdoors to the indoor area.You do not pay to generate the heat, as is the case with more traditional furnace designs.

During summer, the heat pump reverses the fl ow of the heat-absorbing refrigerant to become an energy-effi cient, central air conditioner. Excess heat energy inside the home is absorbed by the refrigerant and exhausted outside the home.

Fan

System

Temperature

Mode

Mode

Selector

 

 

 

Figure 1. Digital Thermostat

Operating Instructions

Cooling Operation

1.Set the thermostat’s system mode to COOL or AUTO and change the fan mode to AUTO. See Figure 1

2.Set the temperature selector to the desired temperature level. The outdoor fan, compressor, and blower motor will all cycle on and off to maintain the indoor temperature at the desired cooling level.

NOTE: If the temperature level is re-adjusted, or the system mode is reset, the fan and compressor in the outdoor unit may not start immediately. A protective timer circuit holds the compressor and the outdoor fan off for approximately three minutes following a previous operation or the interruption of the main electrical power.

Heating Operation

1.Set the thermostat’s system mode to HEAT or AUTO and change the fan mode to AUTO. See Figure 1.

2.Set the temperature selector to the desired temperature level. The compressor, outdoor fan, and blower motor will cycle on and off to maintain the indoor temperature at the desired heating level.

NOTE: If the temperature level is re-adjusted, or the system mode is reset, the fan and compressor in the outdoor unit may not start immediately. A protective timer circuit holds the compressor and the outdoor fan off for approximately three minutes following a previous operation or the interruption of the main electrical power.

Emergency Heat

Some thermostats may include a system mode called EM HT or AUX HT, etc. This is a back- up heating mode that should only be used if a problem is suspected. With the mode set to EM HT, etc., the compressor and outdoor fan will be locked off and supplemental heat (electric resistance heating) will be used as a source of heat.Sustained use of electric resistance heat in place of the heat pump will result in an increase in electric utility costs.

Defrost

During cold weather heating operation, the outdoor unit will develop a coating of snow and ice on the heat transfer coil. This is normal and the unit will defrost itself. This unit features Adaptive Demand Defrost that monitors ambient and coil temperatures to regulate the defrost function accordingly.

3

Image 3
Contents USER’s Manual & Installation Instructions System Operation Safety Information User InformationAbout the Heat Pump Inspecting Equipment Warranty InformationPre-Installation Check General InformationHeat Pump Installation Unit Under the HomeCondensate Drainage Return Duct Installing Return Supply AIR FittingsLocating and Installing Return AIR Assembly Supply DuctTypical Applications Locating and Installing Supply DampersHigh Voltage Connecting the Return and Supply Air Flexible DuctsBlower Speed Electrical ConnectionsSpeed Outdoor Fan Motor Select Models Low Pressure SwitchHigh Pressure Switch Locating the ThermostatX48K Motor Speed Air FlowX24K X36KControl Diagnostic Ambient Sensor Mounting Diagnostic Description LED StatusPre-Start Checklist Start-Up ProcedureDefrost Test Procedure Anti Short Cycle Timer Test Adjustment of Refrigerant ChargeCharging an R-410A Unit in Heating Mode Refrigerant Charging Charts for Cooling Mode of Operation Charging Chart for 4 ton Units Refrigerant Charging Tables for Heating Mode of Operation Q5RF-X48K Ton Units Wiring DiagramQ5RF/PPH2RF Series Small Package H/P ¢709064-¤
Related manuals
Manual 24 pages 38.33 Kb Manual 20 pages 19.69 Kb

R-410A specifications

Nordyne R-410A is a widely recognized refrigerant used in modern air conditioning and heat pump systems, known for its efficiency and environmentally friendly attributes. As a hydrofluorocarbon (HFC) refrigerant, R-410A has become the preferred choice for many manufacturers seeking to meet stringent environmental regulations while providing superior cooling performance.

One of the main features of R-410A is its higher energy efficiency compared to older refrigerants like R-22. This efficiency is primarily attributed to its higher pressure capabilities, which allow for improved heat transfer and reduced energy consumption in residential and commercial systems. As energy costs continue to rise, the use of R-410A in HVAC systems offers a viable solution for reducing utility bills while maintaining optimal comfort levels.

R-410A is also non-ozone-depleting, which sets it apart from many traditional refrigerants. While older refrigerants have been phased out due to their potential harm to the ozone layer, R-410A presents a sustainable alternative that aligns with environmental goals. It features a zero ozone depletion potential (ODP), making it a responsible choice for installations concerned with ecological impact.

In terms of technology, R-410A works effectively in both air conditioning and heat pump systems, providing reliable cooling in hot conditions and heat in colder months. It is compatible with a variety of system designs and can excel in both residential and commercial applications. Moreover, the thermodynamic properties of R-410A ensure consistent and reliable performance, regardless of the external temperature fluctuations.

Another characteristic of R-410A is its ability to operate at lower temperatures, which enhances its versatility. This capability allows for the design of systems that can function efficiently in a wider range of climate conditions. As a result, HVAC technicians and contractors benefit from its reliability and performance, leading to less frequent maintenance and enhanced customer satisfaction.

Lastly, R-410A systems are equipped with advanced components that improve overall functionality. These systems often include variable-speed compressors, which optimize energy use based on cooling demand, and advanced refrigerant management technologies that ensure safe and efficient operation.

In conclusion, Nordyne R-410A stands out as a superior refrigerant due to its energy efficiency, environmental benefits, and adaptability across a range of HVAC applications. As the industry continues to innovate and shift toward sustainable solutions, R-410A remains at the forefront of refrigerant technology, ensuring homeowners and businesses alike enjoy efficient and eco-friendly cooling options.