Bryant 580J*16D instruction manual Safety Considerations, Nameplate Location

Page 2

580J*16D

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloths for brazing operations and have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and appropriate national electrical codes (in USA, ANSI/NFPA70, National Electrical Code (NEC); in Canada, CSA C22.1) for special requirements.

It is important to recognize safety information. This is the

safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, CAUTION, and NOTE. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices, which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

Nameplate Location

!CAUTION

ELECTRICAL HAZARD

Failure to follow this caution may result in personal injury or product and property damage.

The electrical data contained in this document is only for use with 48TC size 16 units which display a “3” in the 13th position of the 17 digit model number as displayed on the unit’s nameplate.

See Fig. 1 for location of the unit’s nameplate. See Fig. 2 for details of the 17 digit model number.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could cause personal injury or death.

Before performing service or maintenance operations on unit, always turn off main power switch to unit and install lockout tag. Unit may have more than one power switch.

Fig. 1 - Location of Unit Nameplate

C11014

2

Image 2
Contents Model Number Nomenclature 580J*16DSafety Considerations Nameplate Location0 J E 1 6 D 2 4 0 a 3 a 0 a a Unit Wire/Fuse or Hacr Breaker Sizing Data

580J*16D specifications

The Bryant 580J*16D is a high-performance, energy-efficient heating and cooling system designed for residential use. This model is part of Bryant's renowned line of home comfort solutions, specifically tailored for homeowners seeking reliability combined with advanced technology.

One of its key features is the two-stage cooling and heating system, which allows for consistent temperature control. This results in a more comfortable living environment by reducing temperature fluctuations. The system operates quietly, thanks to its advanced sound-dampening features which minimize distraction, ensuring that your home remains a peaceful retreat.

The 580J*16D is equipped with a variable-speed compressor, which enhances its energy efficiency. This technology enables the unit to adjust its cooling or heating output based on the current demands of your home. As a result, homeowners can enjoy improved energy savings and reduced utility bills. The model is also designed to operate efficiently even in extreme outdoor conditions, maintaining comfort throughout the year.

In addition to its performance capabilities, the Bryant 580J*16D emphasizes durability. Built with high-quality materials, the system is designed to withstand the rigors of changing weather conditions. Its robust construction ensures a longer lifespan, giving homeowners peace of mind.

Another notable characteristic of the Bryant 580J*16D is its compatibility with smart home technology. The system can easily integrate with various home automation systems, allowing users to control their heating and cooling remotely. This feature provides not only convenience but also enables homeowners to manage their energy consumption effectively.

Moreover, the 580J*16D is compliant with modern standards for sustainability and energy efficiency, making it a responsible choice for environmentally conscious consumers. The unit is certified with high SEER ratings, ensuring reduced greenhouse gas emissions.

In conclusion, the Bryant 580J*16D is an exemplary heating and cooling solution for homes that prioritizes comfort, energy efficiency, durability, and modern technology. With its advanced features, including a variable-speed compressor, quiet operation, and smart home compatibility, this model stands out as an ideal choice for those looking to enhance their indoor living experience while being mindful of energy consumption.