Goodman Mfg GSH13 warranty Ahri Ratings

Page 4

Product Specifications

AHRI Ratings

Outdoor

Indoor

Cooling Capacity¹

SEER²

EER³

TVA Ratings⁴

Heating Capacity¹

CFM

AHRI #

 

 

 

 

 

 

 

Unit

Unit

Total

Sens.

Total

Sens.

High

HSPF⁵

Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GSH130484A*

AR*F486016B*

45,000

33,800

13.0

11.0

41,500

31,800

43,000

8.2

27,000

1,600

1492572

GSH130601A*

AR*F486016B*

55,500

41,000

13.0

11.0

51,500

37,000

55,500

8.5

35,000

1,800

1492576

GSH130603A*

AR*F486016B*

55,500

41,000

13.0

11.0

51,500

37,000

55,500

8.5

35,000

1,800

1492581

GSH130604A*

AR*F486016B*

55,500

41,000

13.0

11.0

51,500

37,000

55,500

8.5

35,000

1,800

1492585

GSH130241(B,C)*

AR*F182416B*+TXV

23,000

17,800

13.0

11.0

21,400

15,800

21,400

7.7

11,800

860

4675037

GSH130301(B,C)*

AR*F363616B*

27,800

20,200

13.0

11.0

25,800

19,300

25,400

7.7

15,300

1,020

4692016

GSH130181(B,C)*

AR*F182416B*

17,600

13,100

13.0

11.0

16,300

11,800

16,800

7.7

8,900

625

4675036

GSH130361(B,C)*

AR*F374316B*

33,600

26,200

13.0

11.0

31,000

23,400

31,400

7.7

18,200

1,260

4692017

GSH130604AC

AR*F486016B*

55,500

41,500

13.0

11.0

51,500

37,000

55,500

8.5

35,000

1,800

4982919

GSH130481B*

AR*F486016B*

45,000

33,800

13.0

11.0

41,500

31,800

43,000

8.2

27,000

1,600

5528480

GSH130421B*

AR*F364216B*

40,000

29,800

13.0

11.0

37,200

28,200

39,000

8.0

23,000

1,250

5528479

GSH130363A*

AR*F374316B*

33,600

26,200

13.0

11.0

31,000

23,400

31,400

7.7

18,200

1,260

5528484

GSH130483B*

AR*F486016B*

45,000

33,800

13.0

11.0

41,500

31,800

43,000

8.2

27,000

1,600

5528481

GSH130484AD

AR*F486016B*

45,000

33,200

13.0

11.0

41,500

31,800

43,000

8.2

27,000

1,600

5528482

 

 

 

 

 

 

 

 

 

 

 

 

 

¹ BTU/h

 

² Seasonal Energy Efficiency Ratio; Certified per AHRI 210/240 @ 80°F/ 67°F/ 95°F

 

 

³ Energy Efficiency Ratio @ 80°F/ 67°F/ 95°F

 

⁴ TVA Rating: BTU/h @ 75°F/ 63°F - 95°F

⁵ HSPF = Heating Seasonal Performance Factor

Notes

 

 

 

 

 

 

 

 

 

 

 

 

Always check the S&R plate for electrical data on the unit being installed.

When matching outdoor unit to indoor unit, use the piston supplied with outdoor unit or that specifiied on the piston kit chart supplied with the indoor unit.

EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not in- terchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay

4

www.goodmanmfg.com

SS-GSH13

Image 4
Contents GSH13 Nomenclature EfficiencySpecifications Ahri Ratings Dimensions Model DimensionsDiagram SpecificationsAccessories GSH13SS-GSH13