White Rodgers F145-1328, F145-1378 specifications Precautions, Specifications

Page 1

F145-1328/F145-1378

Indoor Remote Sensor/Outdoor Remote Sensor

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

INDOOR REMOTE SENSOR

OUTDOOR REMOTE SENSOR

Outdoor Probe

Interior Mounting Base

NOTE

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.

The remote sensors cannot be used with systems where power interruptions are part of normal system operation.

PRECAUTIONS

!CAUTION

To prevent electrical shock and/or equipment dam- age, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

!WARNING

Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard.

Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.

The F145-1328 remote sensor is approved for indoor use only.

Temperature range: 40° to 99°F

SPECIFICATIONS

Operating humidity range: 0 to 90% RH (non-condensing).

20 gauge, three-conductor shielded cable must be used for all remote sensor wiring.

The F145-1378 remote sensor is approved for outdoor use only.

Temperature range of outdoor probe: -40° to 140°F

20 gauge, three-conductor shielded cable must be used for all remote sensor wiring.

White-Rodgers is a division

PART NO. 37-6606A

of Emerson Electric Co.

 

www.white-rodgers.com

0440

 

Image 1
Contents Specifications PrecautionsWiring Installation Indoor SensoroutdoorsensorThermostat only Indoor SensorsSingle Stage Thermostat Remote Sensor Wiring F145-1328 Wiring DiagramsRemote Sensor Calculated Priority Average ConfigurationComfort-Set Comfort-Set III/Comfort-Set 90/90 SeriesTroubleshooting Chart Remote Sensor Troubleshooting GuideComfort-Set Comfort-Set III/Comfort-Set 90/90 Series