White Rodgers 1.00E+56, Type 1E56 Operation Maintenance, Attach Thermostat to Subbase

Page 3

 

 

Cooling

 

 

Anticipator

 

Fan

 

 

Switch

System

AUTO

ON

COOL

 

G

Y

RC

W

Fan

Cooling

 

Heating

Relay

System

 

System

Thermostat

COOL

 

 

 

Contacts

 

 

 

Cooling

 

 

 

 

 

HEAT

In “OFF” position

 

Anticipator

Heating

 

 

 

 

 

 

system switch breaks

 

 

Anticipator

 

Fan

 

 

both heating and

 

 

 

Switch

System

 

 

cooling circuits

HEAT

 

ON

COOL

 

AUTO

 

 

 

4

 

G

Y

RC

W

Field Installed

 

 

 

 

 

Jumper

Fan

Cooling

 

Heating

 

 

 

 

 

Relay

System

 

System

Hot

 

 

 

 

 

24 VAC

120 VAC

 

 

 

 

Neutral

Thermostat COOL

Contacts

 

 

Heating

HEAT

In “OFF” position

 

 

system switch breaks

Anticipator

 

 

both heating and

 

 

HEAT

 

cooling circuits

 

 

4

 

 

 

 

Hot

 

 

 

120 VAC

 

 

 

 

 

 

 

 

 

 

24 VAC

 

 

 

 

 

 

 

Neutral

 

 

 

 

 

 

 

 

 

 

 

 

Hot

 

 

 

 

Heating Transformer

24 VAC

 

 

 

120 VAC

 

 

 

Neutral

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Transformer

Figure 2. For installations where heating and

Figure 3. For installations where heating system

cooling systems are powered by the same transformer

is powered by a separate transformer

 

ATTACH THERMOSTAT TO SUBBASE

1.Remove cover from thermostat base by gripping the base in one hand. Use the other hand to pull gently at the top or bottom of the cover.

2.Carefully remove the shipping protective packing from the switch.

3.Attach thermostat base to subbase, being sure that all captive screws are tightened snugly, since they serve as electrical connections between thermostat and subbase (see fig. 4).

4.Snap cover on thermostat and set switches and tem- perature lever to desired setpoint (see OPERATION section).

5.Turn on power to the system.

Captive screws

O

RH

60

70

80

 

G

50

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

90

Y

RC

 

 

 

 

 

 

W

 

 

 

 

 

 

B

50

60

70

80

 

 

 

 

90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

BASE

COVER

Figure 4. Attach thermostat to subbase

A

 

U

 

T

F

O

 

A

ON

N

C

 

O

 

O

 

L

S

O

Y

F

S

F

T

 

HE E M A T

This thermostat is easy to operate. Fig. 5 shows how the heating/cooling system and fan operate when the switches are in various positions. Use the system switch to select either heating or cooling, or to turn the heating/cooling system off. Use the fan switch to control fan operation. When the fan switch is in the AUTO position, the fan will cycle with the heating or cooling system (the fan will not run if the system switch is in the OFF position and the fan switch is in the AUTO posi- tion). When the fan switch is in the ON position, the fan will run continuously, regardless of system switch position (even if the system switch is set to OFF, the fan will run if the fan switch is in the ON position).

OPERATION &

MAINTENANCE

 

 

Shows switch position

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN

 

 

 

SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTO ON

 

COOL OFF HEAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No heating; no cooling; no fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No heating; no cooling; fan runs continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling system cycles from thermostat; fan runs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling system and fan cycle from thermostat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating system cycles from thermostat; fan cycles

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from fan control on furnace

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating system cycles from thermostat; fan runs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

continuously

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5. Subbase switching and thermostat/system operation

3

Image 3
Contents Description Installation InstructionsPrecautions ContentsAttach Subbase to Wall InstallationRoute Wires to Location Select Thermostat LocationAttach Thermostat to Subbase Operation MaintenanceCalibrating Thermostat Adjusting Heat Anticipator

Type 1E56, 1.00E+56 specifications

White Rodgers 1.00E+56, Type 1E56, is a state-of-the-art thermostat designed for residential and light commercial use. This advanced device brings together user-friendly controls with intelligent features aimed at enhancing energy efficiency and comfort in indoor environments. The White Rodgers brand, a trusted name in HVAC controls and thermostatic technologies, has developed the 1.00E+56 thermostat to meet the needs of modern homes.

One of the standout features of the Type 1E56 is its easy-to-use interface. The unit is equipped with a large, backlit display that clearly shows the current temperature and settings, making it easy for users to read and adjust at any time of day or night. The intuitive buttons allow for convenient navigation through different modes, from heating to cooling, with just a few simple clicks.

The thermostat incorporates advanced programming capabilities, enabling homeowners to set customized schedules that align with their daily routines. With the ability to program multiple time periods throughout the day and week, users can ensure optimal comfort while also minimizing energy consumption. Moreover, the 1E56 supports both 5-2 day programming, which allows different settings for weekdays and weekends, making it a versatile choice for those with varied schedules.

In terms of technology, the White Rodgers 1.00E+56 utilizes precise digital sensing and control, delivering consistent temperature regulation. The unit is compatible with a range of heating and cooling systems, including gas, electric, and heat pump systems, providing flexibility for various HVAC setups. Additionally, features such as adjustable temperature differentials help maintain desired comfort levels while avoiding energy waste.

Compatibility with smart home systems is another advantage of the Type 1E56. While it is primarily a standalone unit, its ease of integration with existing smart technology adds to its appeal for tech-savvy users seeking to enhance their home automation setup.

Durability is another hallmark of the 1.00E+56. Engineered with high-quality materials, this thermostat not only ensures long-lasting performance but also incorporates safety features to prevent overheating and electrical issues.

In conclusion, the White Rodgers 1.00E+56, Type 1E56, combines ease of use, customizable programming, advanced technology, and compatibility with various HVAC systems to deliver an efficient and user-friendly temperature control solution. Its robust features make it an excellent choice for homeowners looking to optimize their indoor climate while maintaining energy efficiency.