Harman Stove Company R7R1 Exception Wood Fireplace manual General Considerations, Insert

Page 4

Exception F200 Wood Insert

Operation

General Considerations

Draft

Before you install and operate your Exception wood insert, please read the entire contents of this manual. Pay particular attention to the explanation of draft and its

effect on insert performance in the Installation section. By following the installation and operating guidelines, you will ensure proper draft and gain maximum efficiency and enjoyment from your insert.

Fuel

Your Exception burns wood very efficiently. Here are some guidelines concerning log size and moisture con- tent that will help you obtain the best performance.

Select hardwoods if possible, as they are heavier and contain more heating capacity (BTU’s) per load than

do softwoods. Wood should be split and stored under cover for “seasoning” - a year is recommended. Your

insert is not an incinerator - do not burn garbage, painted or treated wood, plastic, or other debris.

Keep the area around the insert free from clut- ter. Keep allcombustibles, including fuel, beyond the code- required clearance distance (48" or 1215 mm in the U.S., 1525 mm or 60" in Canada). Never store fuel in front of the insert where it could interfere with door operation, safe loading, and ash removal.

Do not burn garbage or flammable fluids such as gasoline, naptha, or engine oil.

The door must be closed while the insert is in nor- mal operation, and the gaskets routinely examined for wear and replaced when necessary. Good door seals are important for maintaining control of the insert. Operating the insert with the door inadequately sealed, could create a serious over firing condition (discussed later in this sec- tion).

The glass used in your Exception is manufactured to exact standards to withstand the high heat of the fire, but like all glass, it must be treated with common sense and care. Never abuse the glass by slamming the door shut or striking the glass with a heavy object. If the glass is broken or damaged, do not operate the insert until it has been replaced (See instructions in the Maintenance sec- tion.)

Operating As A Fireplace

To operate as a fireplace, open the damper and keep it open. Next, open the door and place the optional screen (part number 3-40-727336) over the door opening. Check for smoke spillage into the room. If smoke is escaping into the room, remove the screen and close the door. Al- ways wear gloves when placing or removing the screen.

Never leave the unit unattended with the door open.

Andirons

The andirons keep the fuel from coming in direct contact with the glass, and keep hot coals and embers from spilling out while reloading. Never build a fire di- rectly against the glass.

Do not use a grate or elevate the fire. Build wood fire directly on insert hearth.

The Insert

Doors

Your insert has a large glass-paneled door for loading and fire viewing. To open the glass door, turn the handles clockwise and pull out; to close the door, return the handles to an open 9 o'clock closed 6 o'clock, and push in to engage the latch while turning the handles counterclockwise.

If the latch on your Exception door needs adjust- ment, follow the instructions given in the Maintenance section of this manual.

FOR USE IN THE U.S. AND CANADA

4

 

Image 4
Contents Harman Exception Wood Fireplace Insert Exception F200 Wood Insert IndexSpecifications Harman Exception, Model F200 General Considerations InsertCombustion Process Building and Maintaining the Fire ControlsReloading BlowerAfter Burner Viewport OverfiringRemoving and Disposing of Ashes Curing PaintGlass Replacement Glass CleaningSurface DoorChimney System GasketsHandle Creosote Formation And Need For RemovalParts To Be Assembled Installation Exception F200 Wood InsertAssembling The Wings Assembling The Corner Panels Floor Protection ClearancesMasonry DirectConnect Installation Masonry Positive Connect InstallationZero Clearance Fireplace Requirements Zero Clearance Fireplace InstallationLeveling Bolts Exception F200 Parts Exception F200 Wood Insert Parts List Coil SpringAppendix a Year Transferable Limited Warranty Residential Year Limited Warranty Commercial

R7R1 Exception Wood Fireplace specifications

The Harman Stove Company R7R1 Exception Wood Fireplace is an exceptional addition to any home, offering a blend of efficiency, style, and advanced technology in a traditional wood-burning fireplace design. Renowned for its commitment to quality and innovative heating solutions, Harman delivers a product that meets the dual demands of aesthetics and environmental responsibility.

One of the standout features of the R7R1 Exception is its impressive heating capacity. This wood fireplace is designed to warm spaces of up to 2,400 square feet, making it ideal for larger homes or open-concept living areas. With a maximum output of 80,000 BTUs, this powerhouse ensures that you will stay cozy even during the coldest winter nights.

In terms of efficiency, the R7R1 Exception boasts an EPA-certified efficiency rating of up to 78%, meaning that it burns exceptionally cleanly while maximizing heat output. This not only reduces your carbon footprint but also lowers the frequency of wood refills, allowing for longer burn times between loads. The intelligent design incorporates advanced combustion technology, which ensures a more complete burn of the wood, leading to reduced emissions and less creosote buildup in the chimney.

The design of the R7R1 Exception is equally impressive, featuring a sleek, modern aesthetic that complements various home decors. The large viewing window provides an expansive view of the flames, enhancing the ambiance of your space. Harman also emphasizes user comfort, equipping the fireplace with a convenient air wash system that keeps the glass clean, ensuring a clear view of the fire.

Another key characteristic of the R7R1 Exception is its versatility. It can be installed either as a traditional flush mount or as a raised fireplace, giving homeowners flexibility in design according to their preferences. Additionally, the fireplace easily integrates with Harman's innovative Smart Air Technology, allowing for precise control over air intake and combustion for optimal heating performance.

Finally, the R7R1 Exception is constructed with high-quality materials and craftsmanship, ensuring durability and longevity. The robust firebox is lined with firebrick, which enhances thermal mass and efficiency, while the solid steel body offers both strength and modern appeal.

In summary, the Harman Stove Company R7R1 Exception Wood Fireplace combines exceptional heating performance, innovative technologies, and an aesthetically pleasing design. Its efficiency, adaptability, and ease of use make it a compelling choice for anyone looking to enhance their home's warmth and charm.