Harman Stove Company R7R1 Exception Wood Fireplace manual Chimney System, Gaskets, Handle

Page 9

Exception F200 Wood Insert

Gaskets

Gaskets are used at strategic positions when build- ing the Harman Exception for controlling the path that incoming and outgoing air and gases take through the in- sert. You must check these gaskets from time to time, and replace them when necessary. The gaskets are made of fiberglass of different sizes (obtainable from Harman Stove Company) and are fixed in place with a high tem- perature gasket cement. To change a gasket, first re- move the worn fiberglass and clean the area with a wire brush. Also clean any other surfaces that come into con- tact with the gasket. Place a small bead of cement in the area under the gasket, then press new gasket material into the channel; do not overlap the ends. Seat the gasket firmly by applying pressure when possible; for example, after changing the door gasket, close the door. Allow the cement to dry before using your insert.

Gaskets are located on the door to provide airtight closure and between the damper and the damper frame.

Handle

The handle on the front door of your Exception is attached to threaded shafts. After a period of time, you may find that the front door does not close as firmly as when your insert was new. This is due to a natural com- pression of the gaskets. To tighten the seal, open the door and rotate the handle one full turn counterclockwise or bend the latch plate on the insert.

The Chimney System

Creosote Formation And Need For Removal

When wood is burned slowly, it produces tar and other organic vapors, as well as soot, which combine with expelled moisture to form creosote . The creosote va- pors condense in the relatively cool chimney flue (associ- ated with a slow burning fire). As a result, creosote ac- cumulates on the flue lining. When ignited, this creosote can result in an extremely hot fire.

The afterburner on the Exception cuts creosote to almost nothing when properly burned with dry seasoned wood.

The chimney should be inspected at least once every two months during the heating season to see if any creosote buildup has occurred. Checking your chimney and chimney connector more frequently, especially while you are getting used to your insert, is recommended. To inspect this system, let the insert cool. Using a flashlight and mirror, check the interior of the chimney connector,

and the chimney itself. If a significant layer of creosote or soot as accumulated (1/8"” or 3 mm) it should be re-

moved to reduce the risk of a chimney fire.

To clean deposits from the surface of the con- nector, use a stiff wire brush after dismantling the con- nector assembly. To clean the chimney, use a specially designed brush sized to fit your particular flue opening, or call an established chimney cleaning service.

At the end of the heating season, perform a thor- ough examination of your chimney system, and have it repaired if necessary.

Do not burn any fuel other than wood, such as char- coal, which can cause increased carbon monoxide pro- duction or overfiring. Never use highly volatile substances in your insert, such as gasoline, which could cause an explosion.

When solid fuels are burned completely, they pro- duce water and carbon dioxide. However, in long slow burns, a substantial amount of carbon monoxide may be produced. If allowed to build up, carbon monoxide (which is odorless) can prove fatally poisonous. Proper ventila- tion and draft will prevent this from happening. If you smell smoke, turn up the air control lever setting, and thor- oughly ventilate your dwelling. During future burns, be careful not to overload the insert with fuel, so you will not be tempted to constantly operate at a low air control set- ting.

Other causes of poor ventilation or draft are icing, exhaust fans, a blocked outside air inlet, and room air starvation. If your insert is sluggish and you get occa- sional odor, check these possibilities and increase the air flow in your home.

Proper Ventilation

Always provide a source of fresh air to the room when the insert is operating.

Blower

The blower on your Harman Exception insert requires very little maintenance. You should, however, keep the air inlet and the motor free of dust.

9

Image 9
Contents Harman Exception Wood Fireplace Insert Index Exception F200 Wood InsertSpecifications Harman Exception, Model F200 Insert General ConsiderationsCombustion Process Controls Building and Maintaining the FireReloading BlowerOverfiring After Burner ViewportRemoving and Disposing of Ashes Curing PaintGlass Cleaning Glass ReplacementSurface DoorGaskets Chimney SystemHandle Creosote Formation And Need For RemovalInstallation Exception F200 Wood Insert Parts To Be AssembledAssembling The Wings Assembling The Corner Panels Clearances Floor ProtectionMasonry Positive Connect Installation Masonry DirectConnect InstallationZero Clearance Fireplace Installation Zero Clearance Fireplace RequirementsLeveling Bolts Coil Spring Exception F200 Parts Exception F200 Wood Insert Parts ListAppendix a Year Limited Warranty Commercial Year Transferable Limited Warranty Residential

R7R1 Exception Wood Fireplace specifications

The Harman Stove Company R7R1 Exception Wood Fireplace is an exceptional addition to any home, offering a blend of efficiency, style, and advanced technology in a traditional wood-burning fireplace design. Renowned for its commitment to quality and innovative heating solutions, Harman delivers a product that meets the dual demands of aesthetics and environmental responsibility.

One of the standout features of the R7R1 Exception is its impressive heating capacity. This wood fireplace is designed to warm spaces of up to 2,400 square feet, making it ideal for larger homes or open-concept living areas. With a maximum output of 80,000 BTUs, this powerhouse ensures that you will stay cozy even during the coldest winter nights.

In terms of efficiency, the R7R1 Exception boasts an EPA-certified efficiency rating of up to 78%, meaning that it burns exceptionally cleanly while maximizing heat output. This not only reduces your carbon footprint but also lowers the frequency of wood refills, allowing for longer burn times between loads. The intelligent design incorporates advanced combustion technology, which ensures a more complete burn of the wood, leading to reduced emissions and less creosote buildup in the chimney.

The design of the R7R1 Exception is equally impressive, featuring a sleek, modern aesthetic that complements various home decors. The large viewing window provides an expansive view of the flames, enhancing the ambiance of your space. Harman also emphasizes user comfort, equipping the fireplace with a convenient air wash system that keeps the glass clean, ensuring a clear view of the fire.

Another key characteristic of the R7R1 Exception is its versatility. It can be installed either as a traditional flush mount or as a raised fireplace, giving homeowners flexibility in design according to their preferences. Additionally, the fireplace easily integrates with Harman's innovative Smart Air Technology, allowing for precise control over air intake and combustion for optimal heating performance.

Finally, the R7R1 Exception is constructed with high-quality materials and craftsmanship, ensuring durability and longevity. The robust firebox is lined with firebrick, which enhances thermal mass and efficiency, while the solid steel body offers both strength and modern appeal.

In summary, the Harman Stove Company R7R1 Exception Wood Fireplace combines exceptional heating performance, innovative technologies, and an aesthetically pleasing design. Its efficiency, adaptability, and ease of use make it a compelling choice for anyone looking to enhance their home's warmth and charm.