THERMOSTAT QUICK REFERENCE

Home Screen Description

Figure 4 – Home Screen Display

Time and Day

Room Temperature and Setting Temperature

(flashes when compressor is in 5 minute lockout)

 

System button for selecting

Heat/Off/Cool or Auto (Heat/Cool)

Fan (Auto/On)

Temperature Up/Down

Indicating the current power level of the 2 "AA" batteries.

Full power remaining.

Note: If is displayed, the thermostat is battery powered. When battery power remaining

is approximately half,will be displayed. If the home is going to be unoccupied for an extended period (over 3 months)

and is displayed, the batteries should be replaced before leaving.

Stage 1

Indicates when thermostat is

calling for Heat or Cool

Half power remaining. ChangeThe batteries should

be replaced at this time.

Menu for Cleaning, Programming and Setting Time

Figure 5 – Programming & Configuration Items

Programming and Configuration Items

1Displays and "Keypad Lockout" when in keypad lockout mode.

Displays and "Temperature Limit" and "Keypad Lockout" when limited range is activated and locked. Displays only "Temperature Limit" when limited range is activated.

2Indicates period of day being programmed.

3RUN SCHEDULE (run program) button.

4SET TIME button or HOLD temperature button.

5Displays "Change Filter" when the system has run for the programmed filter time period as a reminder to change or clean your filter. Displays "Humidifier Pad" when the system has run for the programmed filter time period as a reminder to change or clean your humidifier pad.

6COPY button or INSTALLER CONFIG button.

7CLEAN DISPLAY button allows 30 seconds to wipe off the display or ADVANCE DAY button for programming.

8Used in programming to set time and in configuration menu to change selections.

9"Hold Until" indicates the time when a temporary hold period will end.

10"Hours" and "Days" displays during steps in installer configuration.

 

10

11

 

9

 

 

 

8

 

 

1

 

14

 

2

 

 

 

 

13

12

 

 

 

 

 

 

 

3

7

6

5

4

11The words "Hold At" are displayed when the thermo- stat is in the HOLD mode. "Temporary Hold At" is displayed when the thermostat is in a temporary HOLD mode.

12"Call For Service" indicates a fault in the heating/ cooling system. It does not indicate a fault in the thermostat.

13"Stage 1" indicates when heating or cooling stage is energized.

14"Copy" indicates the copy program feature is being used during programming.

3

Image 3
Contents Specifications ApplicationsSave these instructions for future use Installing New Thermostat InstallationWiring Connections Battery Location Remove Old ThermostatProgramming and Configuration Items Thermostat Quick ReferenceHome Screen Description Configuration Menu INSTALLER/CONFIGURATION MenuINSTALLER/CONFIGURATION Menu Programming Operating Your ThermostatEnergy Saving Factory Pre-Program Planning Your Program ImportantWorksheet for Re-Programming 5+1+1 and 7 Day Program St. Louis, Missouri TroubleshootingSymptom Possible Cause Corrective Action Reset Operation