Heat & Glo LifeStyle FB-Grand Gas Information, Fuel Conversions Gas Connection, Gas Pressures

Page 14

8 Gas Information

A. Fuel Conversions

C. Gas Connection

Before making gas connections ensure that appliance be- ing installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth & Home Technologies specified and approved parts.

Note: Have the gas supply line installed in accordance with local building codes, if any. If not, follow ANSI

223.1.Installation should be done by a qualified installer approved and/or licensed as required by the locality. (In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter).

B. Gas Pressures

Proper input pressures are required for optimum appli- ance performance. Gas line sizing requirements need to be made following NFPA51.

WARNING

Fire Risk. Explosion Hazard.

High pressure will damage valve.

• Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1/2 psig.

Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1/2 psig.

WARNING

Verify inlet pressures.

• High pressure may cause overfire condition.

• Low pressure may cause explosion.

Verify minimum pressures when other household gas appliances are operating.

Install regulator upstream of valve if line pressure is greater than 1/2 psig.

Pressure requirements for appliance are shown in the table below. Minimum pressures must be met when other household gas appliances are operating.

Pressure

Natural Gas

Propane

Minimum inlet pressure

5.0 inches

11.0 inches

w.c.

w.c.

 

Maximum inlet gas pressure

14.0 inches

14.0 inches

w.c.

w.c.

 

Manifold pressure

3.5 inches

10.0 inches

w.c.

w.c.

 

NOTE: A listed (and Commonwealth of Massachusetts ap- proved) 1/2 inch (13 mm) T-handle manual shut-off valve and flexible gas connector are connected to the 1/2 inch (13 mm) control valve inlet.

If substituting for these components, please consult local codes for compliance.

Refer to Reference Section 16 for location of gas line access in appliance.

NOTE: Gas line may be run from either side of the appliance provided the hole in the outer wrap does NOT exceed 2-1/2 inches in diameter and does not penetrate the firebox.

WARNING

Gas Leak Risk

Support control when attaching pipe to prevent bending gas line.

NOTE: The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non-combustible, unfaced insulation to prevent cold air infiltration.

Ensure that gas line does not come in contact with outer wrap of appliance. Follow local codes.

Incoming gas line should be piped into the valve compartment and connected to the 1/2 inch connection on the manual shutoff valve.

Check all fittings and connections of appliance which may have loosened during shipping.

14

Heat & Glo • FB-IN, FB-GRAND783-908 Rev. J • 2/07

Image 14
Contents Models What to do if you smell gasHomeowner Reference Information XxxxxxxxTable of Contents Listing and Code Approvals Tools and Supplies Needed Design and Installation ConsiderationsGetting Started Inspect Appliance and ComponentsLocation Fireplace Size RequirementsMinimum Fireplace Opening Inches MillimetersClearances Clearances to Mantels or other Combustibles above ApplianceTermination Locations Vent Termination Minimum ClearancesHorizontal Venting Vent Information and DiagramsVent Table Key Measuring StandardsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Placing, Securing and Leveling the Appliance Factory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressures Gas InformationFuel Conversions Gas Connection High Altitude Installations Check for GAS LeaksElectrical Information Wiring the ApplianceON/OFF Switch Appliance RequirementsOptional Accessories Junction Box InstallationInstallation for Fan Optional Bend Ground Wire UP Tabs Attach to ANY Metal Surface TemperatureSensor Switch FAN Junction BOXMantel Projections Installing Trim SurroundsFinishing Accessories Appliance SetupClean the Appliance Ember PlacementPositioning the Logs Log Set Assembly LOGS-CFXGB Logs Locating Tabs Grate AssemblyHeat & Glo FB-IN, FB-GRAND 783-908 Rev. J 2/07 CF D E Flat Spot for Log #4 Removing Glass Assembly Glass AssemblyAir Shutter Setting Replacing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance What to do if YOU Smell GAS Lighting ApplianceStanding Pilot Ignition After Appliance is Lit Initial Break-in ProcedureCheck Pilot Flame Appearance Frequently Asked Questions Issue SolutionsStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionMaintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsReference Materials Appliance Dimension DiagramModel Dimensions FB-GRAND FB-INVent Kits Components Direct Vent Flex Liner KitsService Parts Log Set AssemblyService Parts List NG, LP FB-IN Hours AvailableTo Ship Limited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information
Related manuals
Manual 23 pages 37.69 Kb

FB-Grand specifications

Heat & Glo has long been recognized as a leader in the fireplace industry, offering innovative designs that merge function with luxury. Among their notable offerings are the LifeStyle CFX-Grand-B, CFX-IN-B, FB-IN, and FB-Grand models. Each of these fireplaces is engineered to elevate living spaces while providing efficient heating solutions.

The LifeStyle CFX-Grand-B is a contemporary masterpiece that prioritizes versatility and style. This model features a sleek, linear design that can be customized with various finishes, allowing it to seamlessly fit into any interior decor. A standout feature of the CFX-Grand-B is its innovative multi-sided design, enabling a stunning view from multiple angles. With advanced heat distribution technology, it ensures optimal warmth, demonstrating that elegance can coexist with practicality.

Next in line is the CFX-IN-B, which is perfect for those who want to create a focal point in their home without compromising space. This model boasts an impressive array of customizable options, including media choices like decorative stones and glass. The advanced IntelliFire technology allows for easy operation with a simple remote control or a smart home integration, ensuring comfort at the touch of a button. Additionally, the CFX-IN-B's clean aesthetic and efficient heating capabilities make it an excellent choice for modern living areas.

The FB-IN model caters to traditionalists while incorporating modern efficiencies. It features a classic design with large viewing areas, enabling an unobstructed view of the flames. This fireplace is equipped with a powerful blower system that enhances heat circulation throughout the room, allowing for a cozy atmosphere even during the coldest months. The FB-IN’s robust build quality ensures durability, making it a long-lasting addition to any home.

Lastly, the FB-Grand further exemplifies Heat & Glo’s commitment to luxury and performance. With a wider profile, this fireplace creates an expansive canvas for mesmerizing flames, ensuring it becomes the heart of any room. High-efficiency ratings mean it is not only visually appealing but also economical to operate. The FB-Grand integrates seamlessly with Heat & Glo's customizable framing options, allowing homeowners to design a fireplace that fits their unique style.

In conclusion, each of the Heat & Glo LifeStyle models offers distinct features and technological advancements that enhance home heating and aesthetics. They combine stylish design, efficient heating, and user-friendly technology, making them a top choice for those looking to add warmth and sophistication to their living spaces.