Heat & Glo LifeStyle FB-Grand Troubleshooting, Symptom Possible Cause Corrective Action

Page 31

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. Continued

c. Defective valve.

Turn the valve knob to the ON position. Place the

 

 

ON/OFF switch in the ON position. Check the millivolt

 

 

meter a the thermopile terminals. The millivolt meter

 

 

should read greater than 125mV. If the reading is ac-

 

 

ceptable, and if the burner does not come on, replace

 

 

the gas valve.

 

 

 

 

d. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stop-

 

 

page.

 

 

 

 

e. Wall switch or wires are defective.

Follow the corrective action in Symptom and Pos-

 

 

sible Cause 1.a above. Check the switch and wiring.

 

 

Replace where defective.

 

 

 

4. Frequent pilot outage

a. Pilot flame may be too high or too low, or blow-

Clean thermocouple and adjust the pilot flame for

problem.

ing out (high pressure), causing pilot safety to drop

maximum flame impingement. Follow lighting instruc-

 

out.

tions carefully.

 

 

 

5. The pilot and main

a. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish while

 

 

b. Inner vent pipe leaking exhaust gases back into

Check venting system for damage. Replace/repair

in operation.

the system.

improperly assembled pipe sections.

 

 

 

 

 

c. Glass too loose and air tight packet leaks in

Replace glass panel assembly.

 

corners after usage.

 

 

 

 

 

d. Bad thermopile or thermocouple.

Replace if necessary.

 

 

 

 

e. Improper vent cap installation.

Check for proper installation and freedom from debris

 

 

or blockage.

 

 

 

6. Glass soots.

a. Flame impingement.

Adjust the log set so that the flame does not exces-

 

 

sively impinge on it.

 

 

 

 

b. Improper air shutter setting.

Adjust the air shutter located on the control panel.

 

 

 

 

c. Debris around air shutter.

Inspect the opening at the base of the burner. NO MA-

 

 

TERIAL SHOULD BE PLACED IN THIS OPENING.

 

 

 

7. Flame burns blue

a. Insufficient oxygen being supplied.

Ensure that the vent cap is installed properly and free

and lifts off burner.

 

of debris. Ensure that the vent system joints are tight

 

 

and have no leaks.

 

 

Ensure that no debris has been placed at the base of,

 

 

or in the area of the air holes in the center of the base

 

 

pan beneath the burner.

 

 

Ensure that the glass is tightened properly on the unit,

 

 

particularly on top corners.

 

 

 

Heat & Glo • FB-IN, FB-GRAND783-908 Rev. J • 2/07

31

Image 31
Contents What to do if you smell gas ModelsXxxxxxxx Homeowner Reference InformationTable of Contents Listing and Code Approvals Inspect Appliance and Components Design and Installation ConsiderationsGetting Started Tools and Supplies NeededInches Millimeters Fireplace Size RequirementsMinimum Fireplace Opening LocationClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsMeasuring Standards Vent Information and DiagramsVent Table Key Horizontal VentingInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Placing, Securing and Leveling the Appliance Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Wood BurningFuel Conversions Gas Connection Gas InformationGas Pressures Check for GAS Leaks High Altitude InstallationsAppliance Requirements Wiring the ApplianceON/OFF Switch Electrical InformationInstallation for Fan Optional Junction Box InstallationOptional Accessories FAN Junction BOX TemperatureSensor Switch Bend Ground Wire UP Tabs Attach to ANY Metal SurfaceFinishing Installing Trim SurroundsMantel Projections Ember Placement Appliance SetupClean the Appliance AccessoriesLogs Locating Tabs Grate Assembly Positioning the Logs Log Set Assembly LOGS-CFXGBHeat & Glo FB-IN, FB-GRAND 783-908 Rev. J 2/07 CF D E Flat Spot for Log #4 Replacing Glass Assembly Glass AssemblyAir Shutter Setting Removing Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceWhat to do if YOU Smell GAS Check Pilot Flame Appearance Initial Break-in ProcedureAfter Appliance is Lit Issue Solutions Frequently Asked QuestionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksFB-GRAND FB-IN Appliance Dimension DiagramModel Dimensions Reference MaterialsDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsService Parts List NG, LP FB-IN To Ship AvailableHours Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information
Related manuals
Manual 23 pages 37.69 Kb

FB-Grand specifications

Heat & Glo has long been recognized as a leader in the fireplace industry, offering innovative designs that merge function with luxury. Among their notable offerings are the LifeStyle CFX-Grand-B, CFX-IN-B, FB-IN, and FB-Grand models. Each of these fireplaces is engineered to elevate living spaces while providing efficient heating solutions.

The LifeStyle CFX-Grand-B is a contemporary masterpiece that prioritizes versatility and style. This model features a sleek, linear design that can be customized with various finishes, allowing it to seamlessly fit into any interior decor. A standout feature of the CFX-Grand-B is its innovative multi-sided design, enabling a stunning view from multiple angles. With advanced heat distribution technology, it ensures optimal warmth, demonstrating that elegance can coexist with practicality.

Next in line is the CFX-IN-B, which is perfect for those who want to create a focal point in their home without compromising space. This model boasts an impressive array of customizable options, including media choices like decorative stones and glass. The advanced IntelliFire technology allows for easy operation with a simple remote control or a smart home integration, ensuring comfort at the touch of a button. Additionally, the CFX-IN-B's clean aesthetic and efficient heating capabilities make it an excellent choice for modern living areas.

The FB-IN model caters to traditionalists while incorporating modern efficiencies. It features a classic design with large viewing areas, enabling an unobstructed view of the flames. This fireplace is equipped with a powerful blower system that enhances heat circulation throughout the room, allowing for a cozy atmosphere even during the coldest months. The FB-IN’s robust build quality ensures durability, making it a long-lasting addition to any home.

Lastly, the FB-Grand further exemplifies Heat & Glo’s commitment to luxury and performance. With a wider profile, this fireplace creates an expansive canvas for mesmerizing flames, ensuring it becomes the heart of any room. High-efficiency ratings mean it is not only visually appealing but also economical to operate. The FB-Grand integrates seamlessly with Heat & Glo's customizable framing options, allowing homeowners to design a fireplace that fits their unique style.

In conclusion, each of the Heat & Glo LifeStyle models offers distinct features and technological advancements that enhance home heating and aesthetics. They combine stylish design, efficient heating, and user-friendly technology, making them a top choice for those looking to add warmth and sophistication to their living spaces.