E.Junction Box Installation

If the box is being wired from the OUTSIDE of the appliance:

Install the Romexconnector (not included with appliance) in the side wrap.

Loosen two screws on the Romex connector, feed the necessary length of wire through the connector and tighten the screws.

Make all necessary wire connections.

If the box is being wired from the INSIDE of the appliance:

Remove the screw attaching the junction box to the outer shell, rotate the junction box inward to disengage it from the outer shell (see Figure 7.4).

 

 

 

HEAT SHIELD

 

 

 

 

 

14/2WG

 

 

 

 

COPPER GROUND

 

 

WHT

BLK

ATTACHED TO GRN SCREW

 

 

 

 

WITH GRN WIRE

 

 

 

BLK

GREEN WIRE

 

 

WHT

 

 

 

 

INSIDE BOX

 

 

 

 

NOTE: Do NOT wire

 

 

 

 

110VAC to wall switch.

Figure

7.4

Junction Box Detail

 

Pull the electrical wires from outside the appliance through this opening into the valve compartment.

Loosen the two screws on the Romex connector, feed the necessary length of wire through the connector and tighten the screws.

Make all necessary wire connections to the receptacle and assemble the receptacle and cover to the junction box.

F.Wall Switch Installation for Fan (Optional)

If the box is being wired to a wall

 

 

 

 

 

 

 

mounted switch for use with a fan

 

 

 

 

 

 

 

(See Figure 7.5):

 

 

 

 

 

 

 

The power supply for the

 

 

 

 

6 INCH

 

 

appliance must be brought into

 

 

 

 

APPROX.

 

 

 

 

 

 

 

 

 

 

a switch box.

 

FAN

 

 

 

WIRE LEAD

 

 

 

SPEED CONTROL

 

 

 

1 MALE END

 

 

 

(RHEOSTAT)

 

 

 

 

• The power can then be supplied

 

 

 

1 FEMALE END

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

from the switch box to the

 

 

 

 

 

TEMPERATURE

 

 

appliance using a minimum of

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR SWITCH

 

 

14-3 with ground wire.

 

 

 

 

 

WIRE LEAD

 

 

 

 

 

 

 

 

 

• At the switch box connect the

 

 

 

 

 

2 FEMALE ENDS

JUNCTION

 

 

 

 

 

 

BOX

 

black (hot) wire and red (switch

 

 

 

 

 

 

 

 

leg) wire to the wall switch as

 

 

 

 

 

6 INCH

 

 

shown.

 

 

 

 

 

APPROX.

 

 

 

 

 

FAN

 

 

 

 

 

 

 

 

 

 

 

• At the appliance connect the

 

 

 

 

 

 

 

 

black (hot), white (neutral) and

 

 

 

 

 

 

 

 

green (ground) wires to the junc-

 

 

 

 

 

 

 

 

tion box as shown.

 

 

 

 

 

 

 

• Add a 1/4 inch insulated female

 

 

 

PLUG AND WIRE

 

 

 

 

 

 

ASSEMBLY

 

 

 

 

connector to the red (switch leg)

 

 

 

 

 

 

 

 

wire, route it through the knock-

 

 

 

 

 

OPTIONAL

 

 

out in the face of the junction

 

 

 

 

 

 

 

Figure

7.5 Junction Box Wired to Wall Switch

WALL SWITCH

 

 

box, and connect to the top fan

 

 

 

 

 

 

 

 

 

 

switch connector (1/4 inch

 

 

 

 

 

 

 

 

male) as shown.

 

 

 

 

 

 

 

 

Heat & Glo LifeStyle Collection

Twilight-II2087-900

Rev. G •

12/05

17

Image 17
Contents Model Twilight-II Homeowner Reference Information CongratulationsTable of Contents 1Listing and Code Approvals Getting Started Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsSelecting Appliance Location Framing and ClearancesClearances to Combustibles ClearancesHood Mantel Projections Interior onlyAppliance Opening Minimum Clearances Termination LocationsPlacing Metal Hearth Strip Appliance PreparationSecuring and Leveling the Appliance Outside Fuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Electrical Information Recommendation for WireConnecting to the Appliance Wall Switch Optional AccessoriesFan Installation Optional Accessories Requirements Intellifire Ignition System WiringWall Switch Installation for Fan Optional Junction Box InstallationMantel Projections FinishingFacing Material Inside Facing MaterialOutside Facing Material Housewrap Building Paper and Sheathing Clean the Appliance Appliance SetupAccessories Lava Rock and Ember PlacementInch Log Set Assembly LOGS-TWIPositioning the Logs Sharp Notch Sharp Notch Smooth CutoutShutter Settings Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyBefore operating this appliance have a qualified technician Operating InstructionsBefore Lighting Appliance Intellifire Ignition Lighting ApplianceFinal Inspection by After Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Intellifire Ignition System TroubleshootingIntellifire Ignition System Before servicing Maintaining and Servicing ApplianceInspect Maintenance Tasks 13Reference Materials Appliance Dimension DiagramTwilight-II Log Set AssemblyTwilight-II Service Parts ListService Parts Limited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyContact Information

TWILIGHT-II specifications

The Heat & Glo LifeStyle TWILIGHT-II is a revolutionary gas fireplace that delivers an unparalleled ambiance and efficiency to modern living spaces. With its sleek design and cutting-edge technology, it serves as the perfect centerpiece for any room while providing warmth and comfort.

One of the standout features of the TWILIGHT-II is its unique, see-through design, allowing users to enjoy the mesmerizing flames from multiple angles. This flexibility not only enhances the aesthetic appeal of any space but also creates a cozy atmosphere, making it perfect for both entertaining guests and enjoying quiet evenings at home.

The TWILIGHT-II is equipped with advanced ignition technologies, such as the IntelliFire Touch system, which ensures a reliable and easy start every time. This user-friendly touch-sensitive control allows homeowners to ignite the fireplace with a simple press. Furthermore, the system is designed to enhance safety by providing electronic ignition and a backup battery system, ensuring the flames can be lit even during power outages.

Another remarkable characteristic of the TWILIGHT-II is its impressive heat output. With the capacity to generate up to 40,000 BTUs, this fireplace efficiently warms large areas, making it an ideal solution for both residential and commercial spaces. The adjustable flame height is another feature that lets homeowners customize their experience, whether they desire a romantic flicker or a more robust display of flames.

Energy efficiency is a priority with the TWILIGHT-II, which is designed with vent-free technology that maximizes heat retention and minimizes heat loss. The fireplace carries a high efficiency rating, which not only contributes to cost savings on energy bills but also reduces environmental impact.

Additionally, the TWILIGHT-II offers a variety of customizable options to suit individual tastes. With multiple media options such as glass beads, driftwood, and various color choices for the interior, users can create a truly personalized look that complements their décor.

In summary, the Heat & Glo LifeStyle TWILIGHT-II embodies modern fireplace design and technology. With its elegant aesthetics, innovative ignition systems, exceptional heating capabilities, and customizable features, it stands out as a premier choice for homeowners seeking to enhance their living environment. Whether hosting gatherings or enjoying a serene evening alone, the TWILIGHT-II provides the perfect solution to all your heating and aesthetic needs.