Heat & Glo LifeStyle RCOR-HV-IPI, LCOR-HV-IPI Requirements for the Commonwealth of Massachusetts

Page 14

NOTE: The following requirements reference various Massachusetts and national codes not contained in this document.

G.Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, includ- ing but not limited to decks and porches, the following re- quirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall hori- zontal vented gas fueled equipment. It shall be the respon- sibility of the property owner to secure the services of qual- ified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and bat- tery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the ex- haust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installa- tion unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure sepa- rate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall hor- izontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installa- tion of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be sat- isfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instruc- tions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

14

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI2005-900 Rev. K • 11/06

Image 14
Contents ST-HV-IPI LCOR-HV-IPI RCOR-HV-IPI What to do if you smell gasSafety and Warning Information Table of Contents Grate BarService Parts List NG, LP PIER-HV-IPIST-HV-IPI ST-HV-IPI LCOR-HV-IPI LCOR-HV-IPI RCOR-HV-IPI Grate BarRCOR-HV-IPI PIER-HV-IPI, ST-HV-IPI L&RCOR-HV-IPI Appliance Certification Installation CodesHigh Altitude Installations CertificationManufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Fireplaces Diagram of the PIER-HV-IPI Diagram of the ST-HV-IPI Diagram of the LCOR-HV-IPI and RCOR-HV-IPI Locating the Fireplace Clearance RequirementsFraming the Fireplace 787Model AT Each Joint Tems or Components MAY be Used Installing the Vent SystemVent System Approvals Identifying Vent ComponentsStraight OUT Straight UP Vertical VentingMAX .2 M Max. Run 24 610 mmVenting with One 90 Elbow Venting with Two 90 Elbows + H 1 FT Venting with three 90 elbows + V 1 FT + H 1 FT Attach the First Vent Component to the Starting Collars Installing Vent ComponentsVenting Out Vertically Vent TerminationInstall Support Brackets Continue Adding Vent ComponentsAttic Firestop Positioned SO That the Arrow is Pointing UPVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceGas Control System Fireplace Junction BOX in a IPI SystemGas Supply Line Gas Pressure RequirementsAppliance Requirements Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Wall Switch Optional AccessoriesFan Installation Wall Switch Installation for Fan Optional Junction Box Wired to Wall SwitchSealant Material FinishingANY Manner Hearth ExtensionsInstalling Trim, Logs & Ember Material Page Placement of the Ember Material Ember Light Bulb Replacement Placing the Ember MaterialBefore Lighting the Fireplace After the InstallationDouble-check for faulty components Lighting the FireplaceFireplace Maintenance Important Turn OFF the GAS Before Servicing Your Fireplace

PIER-HV-IPI, ST-HV-IPI, RCOR-HV-IPI, LCOR-HV-IPI specifications

The Heat & Glo LifeStyle series, which includes models like the ST-HV-IPI, RCOR-HV-IPI, PIER-HV-IPI, and LCOR-HV-IPI, represents a significant advancement in modern fireplace technology, offering both aesthetic appeal and efficient heating solutions. These models are designed to enhance the beauty and comfort of any living space, merging functional innovation with sophisticated design.

One of the standout features of the LifeStyle series is the inclusion of the Instant Ignition, also known as IPI technology. This allows for quick and effortless lighting of the fireplace, providing immediate warmth and ambiance. With a simple push of a button, users can enjoy the soothing glow of flames without the hassle of matches or kindling. This feature is particularly appreciated during unexpected chilly evenings when you want to create a cozy atmosphere in an instant.

In terms of efficiency, all models in the LifeStyle series utilize advanced venting technologies, which ensure that heat is directed effectively into the living space while maximizing fuel efficiency. The linear design options combined with versatile venting configurations allow homeowners to install these fireplaces in various locations, making them adaptable for different room layouts and styles.

The aesthetic appeal of the LifeStyle fireplaces is heightened by customizable options. Users can choose from a wide array of face options, styles, and finishes to match their home décor. The glass viewing area is designed to be expansive, providing a warm and inviting view of the flames, while the clean, contemporary lines of the units make them suitable for both modern and traditional interiors.

Moreover, the LifeStyle series is equipped with remote control features that enhance user convenience. Homeowners can easily adjust flame height, heat output, and lighting without leaving the comfort of their seating area.

Safety is another crucial aspect of the LifeStyle series. The fireplaces include safety components such as an automatic shut-off that activates under certain conditions, providing peace of mind for families with children or pets.

Overall, the Heat & Glo LifeStyle ST-HV-IPI, RCOR-HV-IPI, PIER-HV-IPI, and LCOR-HV-IPI models epitomize modern fireplace design, combining efficiency and style with advanced technology and user-friendly features, making them a perfect choice for anyone looking to enhance their home environment.