Heat & Glo LifeStyle ST-HV-IPI, LCOR-HV-IPI, RCOR-HV-IPI, PIER-HV-IPI Fireplace Maintenance

Page 45

4Maintaining and Servicing Your Fireplace

Fireplace Maintenance

Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE.

Replacing old ember material

Frequency: Once annually, during the checkup.

By: Qualified service technician.

Task: Brush away loose ember material near the burner. Replace old ember material with new dime-size and shape pieces of Golden Ember (GE-93) and Glowing Ember (050- 721). New ember material should be placed alternately on top of the burner - a layer of Golden Ember, a layer of Glowing Ember, and so on. Save the remaining ember material and repeat this procedure at your next servicing. For more information, see Placing Ember Material.

Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician.

Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)

Frequency: Periodically.

By: Qualified service technician.

Task: Make a visual check of the straight flame sensor rod. Use emery cloth to carefully remove any existing white film or deposits.

Checking Flame Patterns, Flame Height

Frequency: Periodically.

By: Qualified service technician/Home owner.

Task: Make a visual check of your fireplace’s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 54. The flame sensor (IPI) tip should be covered with flame. See Figure 32.

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

Figure 54. Burner Flame Patterns

Checking Vent System

Frequency: Before initial use and at least annually thereafter, more frequently if possible.

By: Qualified service technician/Home owner.

Task: Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air. Inspect entire vent system for proper function.

Cleaning Glass Door

Frequency: After the first 3 to 4 hours of use. As neces- sary after initial cleaning.

By: Home owner.

Task: Remove and clean glass after the first 3 to 4 hours of use. After the initial cleaning, clean as necessary, particu- larly after adding new ember (flame colorant) material. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner. NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners.

Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI2005-900 Rev. K • 11/06

45

Image 45
Contents What to do if you smell gas ST-HV-IPI LCOR-HV-IPI RCOR-HV-IPISafety and Warning Information Table of Contents Bar GratePIER-HV-IPI Service Parts List NG, LPST-HV-IPI ST-HV-IPI LCOR-HV-IPI LCOR-HV-IPI Grate Bar RCOR-HV-IPIRCOR-HV-IPI PIER-HV-IPI, ST-HV-IPI L&RCOR-HV-IPI High Altitude Installations Installation CodesAppliance Certification CertificationRequirements for the Commonwealth of Massachusetts Vent Directly BELOW. Keep Clear of ALL OB- StructionsManufacturer Requirements Pre-install Preparation Introducing the Heat & Glo Gas FireplacesANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the PIER-HV-IPI Diagram of the ST-HV-IPI Diagram of the LCOR-HV-IPI and RCOR-HV-IPI Clearance Requirements Locating the Fireplace787 Framing the FireplaceModel AT Each Joint Vent System Approvals Installing the Vent SystemTems or Components MAY be Used Identifying Vent ComponentsMAX .2 M Straight UP Vertical VentingStraight OUT Max. Run 24 610 mmVenting with One 90 Elbow Venting with Two 90 Elbows + H 1 FT Venting with three 90 elbows + V 1 FT + H 1 FT Venting Out Vertically Installing Vent ComponentsAttach the First Vent Component to the Starting Collars Vent TerminationContinue Adding Vent Components Install Support BracketsPositioned SO That the Arrow is Pointing UP Attic FirestopVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Gas Control System Positioning, Leveling, and Securing the FireplaceSecuring of a Fireplace Fireplace Junction BOX in a IPI SystemGas Pressure Requirements Gas Supply LineWiring the Fireplace For Intermittent Pilot Ignition Wiring Operation using Battery PowerAppliance Requirements Optional Accessories Fan InstallationWall Switch Junction Box Wired to Wall Switch Wall Switch Installation for Fan OptionalANY Manner FinishingSealant Material Hearth ExtensionsInstalling Trim, Logs & Ember Material Page Placing the Ember Material Placement of the Ember Material Ember Light Bulb ReplacementDouble-check for faulty components After the InstallationBefore Lighting the Fireplace Lighting the FireplaceImportant Turn OFF the GAS Before Servicing Your Fireplace Fireplace Maintenance

PIER-HV-IPI, ST-HV-IPI, RCOR-HV-IPI, LCOR-HV-IPI specifications

The Heat & Glo LifeStyle series, which includes models like the ST-HV-IPI, RCOR-HV-IPI, PIER-HV-IPI, and LCOR-HV-IPI, represents a significant advancement in modern fireplace technology, offering both aesthetic appeal and efficient heating solutions. These models are designed to enhance the beauty and comfort of any living space, merging functional innovation with sophisticated design.

One of the standout features of the LifeStyle series is the inclusion of the Instant Ignition, also known as IPI technology. This allows for quick and effortless lighting of the fireplace, providing immediate warmth and ambiance. With a simple push of a button, users can enjoy the soothing glow of flames without the hassle of matches or kindling. This feature is particularly appreciated during unexpected chilly evenings when you want to create a cozy atmosphere in an instant.

In terms of efficiency, all models in the LifeStyle series utilize advanced venting technologies, which ensure that heat is directed effectively into the living space while maximizing fuel efficiency. The linear design options combined with versatile venting configurations allow homeowners to install these fireplaces in various locations, making them adaptable for different room layouts and styles.

The aesthetic appeal of the LifeStyle fireplaces is heightened by customizable options. Users can choose from a wide array of face options, styles, and finishes to match their home décor. The glass viewing area is designed to be expansive, providing a warm and inviting view of the flames, while the clean, contemporary lines of the units make them suitable for both modern and traditional interiors.

Moreover, the LifeStyle series is equipped with remote control features that enhance user convenience. Homeowners can easily adjust flame height, heat output, and lighting without leaving the comfort of their seating area.

Safety is another crucial aspect of the LifeStyle series. The fireplaces include safety components such as an automatic shut-off that activates under certain conditions, providing peace of mind for families with children or pets.

Overall, the Heat & Glo LifeStyle ST-HV-IPI, RCOR-HV-IPI, PIER-HV-IPI, and LCOR-HV-IPI models epitomize modern fireplace design, combining efficiency and style with advanced technology and user-friendly features, making them a perfect choice for anyone looking to enhance their home environment.