White Rodgers 1F95-1271 specifications Applications, Specifications, Index, Part no -6735A

Page 1

90 Series Blue Universal Thermostat with Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage, Heat Pump

Installation and Operating Instructions for Model:

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

Model

Programming Choices

 

 

 

 

1F95-1271

Non-Programmable

5/1/1 Day

7 Day

 

 

 

 

APPLICATIONS

THERMOSTAT APPLICATION GUIDE

 

1F95-1271 Touchscreen Thermostat

 

 

 

 

 

 

Description

 

 

Heat Pump (No Aux. or Emergency Heat)

 

Yes

 

Heat Pump (with Aux. or Emergency Heat)

 

Yes

 

Systems with up to 3 Stages Heat, 2 Stages Cool

 

Yes

 

Heat Only Systems

 

Yes

 

Millivolt Heat Only Systems – Floor or Wall Furnaces

 

Yes

 

Cool Only Systems

 

Yes

 

Gas or Oil Heat

 

Yes

 

Electric Furnace

 

Yes

 

Hydronic (Hot Water) Zone Heat – 2 Wires

 

Yes

 

Hydronic (Hot Water) Zone Heat – 3 Wires

 

No

 

 

 

 

 

SPECIFICATIONS

Electrical Rating:

 

Battery Power

mV to 30 VAC, NEC Class II, 50/60 Hz or DC

Input-Hardwire

20 to 30 VAC

Terminal Load

1.5 A per terminal, 2.5A maximum all terminals combined

Setpoint Range

45 to 99°F (7 to 32°C)

Differential (Single Stage)

Heat 0.6°F; Cool 1.2°F

Differential (Multi-Stage)

Heat 0.6°F; Cool 1.2°F

Differential (Heat Pump)

Heat 1.2°F; Cool 1.5°F

Operating Ambient

32° to +105°F (0 to +41°C)

Operating Humidity

90% non-condensing max.

Shipping Temperature Range

-4 to +150°F (-20 to +65°C)

Dimensions Thermostat

4.6"H x 5.9"W x 1.2"D

 

 

!CAUTION

To prevent electrical shock and/or equipment dam- age, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.

Index

Page

 

 

Installation

2

Wiring Connections

2

Thermostat Quick Reference

3

Installer Configuration Menu

4

Operating Your Thermostat

6

Programming

6

Troubleshooting

8

ATTENTION: MERCURY NOTICE

This product does not contain mercury. However, this product may replace a product that contains mercury.

Mercury and products containing mercury must not be discarded in household trash. Do not touch any spilled mercury. Wearing non-absorbent gloves, clean up any spilled mercury and place in a sealed container. For proper disposal of a product containing mercury or a sealed container of spilled mercury, place it in a suitable shipping container and send it to:

White-Rodgers

2895 Harrison Street

Batesville, AR 72501

PART NO. 37-6735A

www.white-rodgers.com

0544

Image 1
Contents Applications SpecificationsSave these instructions for future use IndexWiring Connections InstallationInstalling New Thermostat Battery LocationThermostat Quick Reference Programming and Configuration ItemsHome Screen Description Configuration Menu INSTALLER/CONFIGURATION MenuINSTALLER/CONFIGURATION Menu Programming Operating Your ThermostatPlanning Your Program Important Energy Saving Factory Pre-ProgramWorksheet for Re-Programming 5+1+1 and 7 Day Program Symptom Possible Cause Corrective Action TroubleshootingReset Operation St. Louis, Missouri