White Rodgers 1F95-1271 specifications INSTALLER/CONFIGURATION Menu, Configuration Menu

Page 4

INSTALLER/CONFIGURATION MENU

To enter the menu: Press the Menu button. Press and hold for 5 seconds the Installer Config button. This displays menu item #1 in the table below. Press to advance to the next menu item or to return to a previous menu item. Press or to change a menu item.

 

 

 

 

 

CONFIGURATION MENU

Menu

 

Non-

 

Displayed

Press

or

 

 

 

 

 

 

 

Reference

Program-

Program-

Press

(Factory

to select from

 

Number

mable

mable

Button

Default)

listed options

Comments

 

 

 

 

 

 

 

1

1

1

 

MS 2

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1

 

 

 

 

 

 

 

 

 

(HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor

 

 

 

 

 

 

 

 

 

or 2 speed compressor), or Single Stage.

2

2

2

 

(GAS)

ELE

 

 

 

GAS setting: furnace controls blower.

 

 

 

 

 

 

 

 

 

ELE setting: thermostat controls blower.

3

3

3

 

Days (7)

5, 0

 

 

 

Selects programming option.

4

4

* NA

 

PS (4)

2

 

 

 

Selects programming steps per day.

5

5

4

 

Cool Off

Cool Off Heat (Emer),

Selects system switch configuration for Heat and Cool with

 

 

 

 

Heat Auto

Off Heat, Cool Off

Auto changeover, Heat & Cool, Heat Only or Cool Only.

6

6

* NA

 

E (On)

OFF

 

 

 

Selects Energy Management Recovery on or off.

7

7

5

 

Cr Heat (FA)

SL

 

 

 

Selects Heat cycle rate Fast (FA) or Slow (SL).

8

8

6

 

Cr Cool (FA)

SL

 

 

 

Selects Cool cycle rate Fast (FA) or Slow (SL).

9

9

7

 

Cr Emer (FA)

SL

 

 

 

If HP 1 or HP 2 is selected for item #1, selects Emer cycle

 

 

 

 

 

 

 

 

 

rate.

10

10

8

 

CL (OFF)

On

 

 

 

Selects Compressor lockout ON or OFF.

11

11

9

 

dL (On)

OFF

 

 

 

Selects display light on or off.

12

12

10

 

0

1, 2, 3, 4 HI

Selects temperature display adjustment 1, 2, 3 or 4 degrees

 

 

 

 

(Room temp)

1, 2, 3, 4 LO

high or low.

13

13

11

 

°F

°C

 

 

 

Selects Fahrenheit or Celsius temperature display.

14

14

12

 

b (On)

OFF

 

 

 

Selects beeper on or off.

15

15

13

 

Heat (99)

62-99

 

 

Selects highest Heat setpoint temperature.

 

 

 

 

 

 

 

 

 

Can select 62° to 99°F.

16

16

14

 

Cool (45)

45-82

 

 

Selects lowest Cool setpoint temperature.

 

 

 

 

 

 

 

 

 

Can select 45° to 82°F.

17

17

15

 

Keypad

L, P

 

 

 

Selects keypad lockout full or partial to be set.

 

 

 

 

lockout (L)

Temperature Limit

Activates temperature limit ranges.

18

18

16

 

Keypad

On

 

 

 

Selects keypad lockout on or off.

 

 

 

 

lockout (OFF)

 

 

 

 

 

 

 

 

 

000

000 to 999

Selects keypad lockout combination number if lockout is on.

 

 

 

 

 

 

 

 

 

000 is not a valid selection.

19

19

17

 

FA Heat (On)

OFF

 

 

 

If HP or MS selected in item 1, selects Heat Fast second

 

 

 

 

 

 

 

 

 

stage On or Off.

20

20

18

 

FA Cool (On)

OFF

 

 

 

If HP or MS selected in item 1, selects Cool Fast second

 

 

 

 

 

 

 

 

 

stage On or Off.

21

21

19

 

000 Change

On

 

 

 

Select change filter alert time period.

 

 

 

 

Filter (OFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200 hours

25 to 1975 hours

When set ON, selects time in 25 hour increments.

22

22

20

 

Change

On

 

 

 

Selects change humidifier pad alert time period

 

 

 

 

Humidifier

 

 

 

 

 

 

 

 

 

(OFF)

 

 

 

 

 

 

 

 

 

100 hours

25 to 1975 hours

When set ON, selects time in 25 hour increments.

* Not Applicable

 

 

 

 

 

 

 

 

1)This control can be configured for:

MS2 – Multi-Stage System (no heat pump)

HP1 – Heat Pump with one stage of compressor HP2 – Heat Pump with two stage compressor or two compressor system, Gas or Electric backup

SS1 – Single Stage System

2)GAS or Electric (ELE) fan operation. If the heating system requires the thermostat to energize the fan, select ELE. Select GAS if the heating system energizes the fan on a call for heat. Note: Resetting the thermostat switches the option to ELE.

4

3)This control can be configured for 7 independent day or 5/1/1 day programming or non-programmable mode. The display indicates "7 Days" as default. The programs per

week can be toggled to "5 Days" or "0 Days" by pressing the or keys. A selection of 0 Days for non-program- mable will eliminate the need for EMR, and that step

in the menu will be skipped.

4)Programmable Periods – This control can be configured for 4 or 2 programmable periods per day. The display

indicates "4 PS" in the display as default. The program- mable periods can be toggled by pressing the or keys.

Image 4
Contents Specifications ApplicationsSave these instructions for future use IndexInstallation Wiring ConnectionsInstalling New Thermostat Battery LocationThermostat Quick Reference Programming and Configuration ItemsHome Screen Description INSTALLER/CONFIGURATION Menu Configuration MenuINSTALLER/CONFIGURATION Menu Operating Your Thermostat ProgrammingPlanning Your Program Important Energy Saving Factory Pre-ProgramWorksheet for Re-Programming 5+1+1 and 7 Day Program Troubleshooting Symptom Possible Cause Corrective ActionReset Operation St. Louis, Missouri