SPECIFICATIONS

ELECTRICAL RATINGS [@ 77°F (25°C)]: Input Voltage: 25 VAC 50/60 Hz

Max. Input Current @ 25 VAC: 0.45 amp Relay Load Ratings:

Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf

Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive)

Inducer Relay: 2.2 FLA–3.5 LRA @ 120 VAC

Circulator Relay: 14.5 FLA–25.0 LRA @ 120 VAC

Flame Current Requirements:

Minimum current to insure flame detection: 1 µa DC*

Maximum current for non-detection: 0.1 µa DC*

Maximum allowable leakage resistance: 100 M ohms *Measured with a DC microammeter in the flame probe lead

OPERATING TEMPERATURE RANGE: -40° to 175°F (-40° to 80°C)

HUMIDITY RANGE:

5% to 93% relative humidity (non-condensing)

MOUNTING:

Surface mount multipoise

 

Timing Specs: (@ 60 Hz**)

maximum

 

Flame Establishing Time:

0.8 sec

Flame Failure Response Time:

2.0 sec

**At 50 Hz, all timing specifications should be increased by 20%

Gases Approved: Natural, Manufactured, Mixed, Liqui- fied Petroleum, and LP Gas Air Mixtures are all approved for use.

TIMING SPECIFICATIONS

(All times are in seconds, unless noted otherwise

 

50A55-743

Pre-Purge

15

Initial Ignitor Warm-up

7

(1st 64 attempts)

 

Minimum Ignitor Warm-up

5

Maximum Ignitor Warm-up

9

Ignition Activation Period

2

Trial for Ignition Period

4

Retries

2 times

Valve Sequence Period

12

Interpurge

30

Post-Purge

15

Lockout Time

300

Heat Delay-To-Fan-On

30

Heat Delay-To-Fan-Off*

90/120/150/180

Cool Delay-To-Fan-On

5

Cool Delay-To-Fan-Off

45

Auto Reset

60 minutes

Humidifier

Yes

Electronic Air Cleaner

Yes

*These times will vary depending on option switch position. See OPERATION section for further information

INSTALLATION

MOUNTING AND WIRING

All wiring should be installed according to local and na- tional electrical codes and ordinances.

The control must be secured to an area that will experience a minimum of vibration and remain below the maximum ambient temperature rating of 175°F. The control is ap- proved for minimum ambient temperatures of -40°F.

Any orientation is acceptable.

Refer to the wiring diagram and wiring table when connect- ing the 50A55 control to other components of the system.

UL approved, 105°C rated 18 gauge, stranded, 2/64” thick insulation wire is recommended for all low voltage safety circuit connections. Refer to 50A55 specification sheet for recommended terminals to mate with those on the control.

UL approved 105°C rated 16 gauge min., stranded, 4/64” thick insulation wire is recommended for all line voltage connections. Refer to 50A55 specification sheet for rec- ommended terminals to mate with those on the control.

After installation or replacement, follow appliance manu- facturer’s recommended installation or service instructions to ensure proper operation.

The 50A55 has only one serviceable part–an automotive type fuse, which protects the low voltage transformer from damage if its output is short-circuited. If the fuse has opened up, remove whatever caused the short circuit and replace the fuse with only a 3 Amp automotive type fuse. If the fuse is not the cause of the control’s problem, replace the entire 50A55 control. There are no other user serviceable parts.

!CAUTION

Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat.

!WARNING

FIRE HAZARD

Do not exceed the specified voltage.

Replace existing control with exact model and dash number.

Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

If the control has been in direct contact with water, replace the control.

Label all wires before disconnection when servic- ing controls.Wiring errors can cause improper and dangerous operation.

Route and secure wiring away from flame.

SHOCK HAZARD

Disconnect electric power before servicing.

Ensure proper earth grounding of appliance.

Ensure proper connection of line neutral and line hot wires.

EXPLOSION HAZARD

Shut off main gas to appliance until installation is complete.

2

Image 2
Contents Description Installation InstructionsPrecautions Mounting and Wiring SpecificationsInstallation Wiring Typical System Wiring DiagramTypical System Wiring Table ConnectionCool Mode Option SwitchesHeat Mode OperationSystem Lockout Features Operation Manual FAN on ModeSystem Lockout Diagnostic Features Diagnostic Features

50A55-743 specifications

The White Rodgers 50A55-743 is a versatile and highly efficient universal gas furnace control board widely recognized for its reliability and advanced features. Designed to enhance the performance and safety of heating systems, it caters to both residential and commercial applications, making it a preferred choice for HVAC professionals and homeowners alike.

One of the standout features of the 50A55-743 is its universal compatibility. It is designed to work with a variety of gas furnaces from different manufacturers, significantly simplifying the installation and replacement process. This feature saves time and reduces overhead costs for technicians, as they no longer have to stock multiple control boards for various furnace models.

The control board operates using advanced microprocessor technology, which ensures precise control over the heating cycle. This precision translates into optimal comfort for the occupants and can lead to significant energy savings. The board is capable of monitoring and adjusting the heating process in real-time, adapting to the specific demands of the environment.

Another important characteristic of the White Rodgers 50A55-743 is its built-in diagnostics. The board features LED indicators that provide real-time feedback on the furnace's operational status. These diagnostic lights help technicians quickly identify issues, minimizing downtime and improving service efficiency. Together with its user-friendly design, these features make troubleshooting a more straightforward process.

Safety is a paramount consideration in HVAC systems, and the 50A55-743 excels in this aspect as well. It includes multiple safety features such as flame proving, limit control, and lockout capabilities, which enhance the operational integrity of the furnace. These features help to prevent unsafe operating conditions, providing peace of mind for users.

The control board can also work with variable speed blower motors, allowing it to effectively manage airflow and heating output, leading to improved efficiency and comfort levels. Its adaptability to different configurations makes it a powerful component in modern HVAC systems.

In conclusion, the White Rodgers 50A55-743 stands out as a leading control board in the HVAC industry. With its universal compatibility, advanced microprocessor technology, built-in diagnostics, and robust safety features, it represents a significant advancement in furnace control, enhancing reliability, efficiency, and overall user satisfaction. This makes it an excellent choice for anyone looking to upgrade their heating system.