White Rodgers 50A55-743 installation instructions Installation Instructions, Description

Page 1

50A55-743

Integrated Furnace Control

INSTALLATION INSTRUCTIONS

FAILURETO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

The 50A55-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan.

Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation.

These controls incorporate system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction. It is designed as a replacement for the following controls:

 

Goodman

 

White-Rodgers

 

 

 

 

0130F00005

PCBBF110

PCBBF123

50A55-743

0130F00005S

PCBBF110S

PCBBF123S

50A55-289

B1809926

PCBBF112

 

50T55-289

B1809926S

PCBBF112S

 

 

PRECAUTIONS

Installation should be done by a qualified heating and air conditioning contractor or licensed electrician.

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or licensed electrician.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

Following installation or replacement, follow manufacturer’s recommended installation/service instructions to ensure proper operation.

!CAUTION

Do not short out terminals on gas valve or primary control. Short or incorrect wiring may damage the thermostat.

!WARNING

Failure to comply with the following warnings could result in personal injury or property damage.

FIRE HAZARD

Do not exceed the specified voltage.

Replace existing control with exact model and dash number.

Protect the control from direct contact with water

(dripping, spraying, rain, etc.).

If the control has been in direct contact with water, replace the control.

Label all wires before disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.

Route and secure wiring away from flame.

SHOCK HAZARD

Disconnect electric power before servicing.

Ensure proper earth grounding of appliance.

Ensure proper connection of line neutral and line hot wires.

EXPLOSION HAZARD

Shut off main gas to appliance until installation is complete.

www.white-rodgers.com

PART NO. 37-7348A

 

www.emersonclimate.com

1226

Image 1
Contents Precautions Installation InstructionsDescription Installation SpecificationsMounting and Wiring Typical System Wiring Diagram WiringConnection Typical System Wiring TableHeat Mode Option SwitchesCool Mode OperationSystem Lockout Diagnostic Features Operation Manual FAN on ModeSystem Lockout Features Diagnostic Features

50A55-743 specifications

The White Rodgers 50A55-743 is a versatile and highly efficient universal gas furnace control board widely recognized for its reliability and advanced features. Designed to enhance the performance and safety of heating systems, it caters to both residential and commercial applications, making it a preferred choice for HVAC professionals and homeowners alike.

One of the standout features of the 50A55-743 is its universal compatibility. It is designed to work with a variety of gas furnaces from different manufacturers, significantly simplifying the installation and replacement process. This feature saves time and reduces overhead costs for technicians, as they no longer have to stock multiple control boards for various furnace models.

The control board operates using advanced microprocessor technology, which ensures precise control over the heating cycle. This precision translates into optimal comfort for the occupants and can lead to significant energy savings. The board is capable of monitoring and adjusting the heating process in real-time, adapting to the specific demands of the environment.

Another important characteristic of the White Rodgers 50A55-743 is its built-in diagnostics. The board features LED indicators that provide real-time feedback on the furnace's operational status. These diagnostic lights help technicians quickly identify issues, minimizing downtime and improving service efficiency. Together with its user-friendly design, these features make troubleshooting a more straightforward process.

Safety is a paramount consideration in HVAC systems, and the 50A55-743 excels in this aspect as well. It includes multiple safety features such as flame proving, limit control, and lockout capabilities, which enhance the operational integrity of the furnace. These features help to prevent unsafe operating conditions, providing peace of mind for users.

The control board can also work with variable speed blower motors, allowing it to effectively manage airflow and heating output, leading to improved efficiency and comfort levels. Its adaptability to different configurations makes it a powerful component in modern HVAC systems.

In conclusion, the White Rodgers 50A55-743 stands out as a leading control board in the HVAC industry. With its universal compatibility, advanced microprocessor technology, built-in diagnostics, and robust safety features, it represents a significant advancement in furnace control, enhancing reliability, efficiency, and overall user satisfaction. This makes it an excellent choice for anyone looking to upgrade their heating system.