Models 427G and 427RG Installation | 18 |
|
|
Electrical Requirements
For models 427G and 427RG, the electrical supply should be located within the shaded area shown in the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
IMPORTANT NOTE: For models 427G and 427RG, the electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall.
Electrical Requirements
Power Supply | 115 V AC, 60 Hz |
Circuit Breaker | 15 amp |
Receptacle | |
|
|
| LEFT SIDE |
| OF OPENING |
21/2" |
|
(64) | 13" (330) |
| |
| 41/2" |
| (114) |
1/4" | FLOOR |
(6) | FRONT VIEW |
Location of electrical supply.
The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded.
Do not use an extension cord or