For models 427G and 427RG, the electrical supply should be located within the shaded area shown in the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

Models 427G and 427RG Installation

18

 

 

Electrical Requirements

For models 427G and 427RG, the electrical supply should be located within the shaded area shown in the illustration below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

IMPORTANT NOTE: For models 427G and 427RG, the electrical outlet must be placed so the grounding prong is to the right of the thinner blades. The outlet must be flush with the back wall.

Electrical Requirements

Power Supply

115 V AC, 60 Hz

Circuit Breaker

15 amp

Receptacle

3-prong grounding-type

 

 

 

LEFT SIDE

 

OF OPENING

21/2"

 

(64)

13" (330)

 

 

41/2"

 

(114)

1/4"

FLOOR

(6)

FRONT VIEW

Location of electrical supply.

The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded.

Do not use an extension cord or two-prong adapter. Do not remove the power supply cord ground prong.