Models 427G and 427RG Installation | 24 |
|
|
Wiring Connections
Before the kickplate/grille is installed, all necessary wiring connections in the compressor compartment should be completed.
If the dual installation heater kit is used with model 427G or 427RG, the power supply leads should be connected according to instructions included with the kit.
If a home alarm system is to be installed on the wine storage unit, the connections should be made using the logic supplied with the alarm specifications. Refer to the illustration below for the appliance lead locations, and refer to the following for color codes:
•Normally open contacts: white with red stripe wire.
•Normally closed contacts: white with blue stripe wire.
•Common: gray with white stripe wire.
Use the 1/4" spade terminals or wire nuts provided to make the proper wiring connections.
IMPORTANT NOTE: If you are not responsible for alarm system connection, this information should be supplied to the home security system contractor.
HOME ALARM |
CONNECTIONS |
Home alarm connections.
The alarm circuit in the unit is intended as a low- voltage,
Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components.