Models 424G and 424FSG Installation

10

 

 

Position the Unit

If you are adding an accessory lock kit to your wine storage unit, it should be installed before you position the unit. The accessory lock kit and additional instructions are available through your authorized Sub-Zero dealer, or call Sub-Zero at 800-222-7820. You can also visit our website at subzero.com.

IMPORTANT NOTE: If for any reason the wine storage unit has been laid on its back or side, you must allow the unit to stand upright for a minimum of 24 hours before con- necting power.

Plug the power cord into the grounded electrical outlet. With power applied to the appliance, check for lighting and cooling before going any further. Once you are satis- fied that the unit is operating properly, shut off power to the electrical outlet at the circuit breaker and proceed.

Pre-level the wine storage unit before sliding it into position. Leveling cannot be completed with the unit pushed back in the installation opening.

If a home alarm system is to be used with the wine storage unit, the lead wires should be threaded into the compressor compartment before you position the unit. Refer to home alarm connections on the following page, for the location of these lead wires. After the unit is in position, the alarm wiring can be completed from the front.

For model 424FSG, adust the leveling legs so the top of the unit is no more than 345/8" (879) above the floor. This is to allow the unit to engage the anti-tip bracket properly. Center the model 424FSG in front of the anti-tip bracket.

Slide the unit into position, making sure the anti-tip bracket is engaged properly.

When the wine storage unit is installed, the anti-tip bracket will be positioned just below the engaging bracket on the unit. It is not necessary to raise the unit up so that it locks into the anti-tip bracket, but the unit must be in alignment with the anti-tip bracket.

The wine storage unit provides the best access to its contents when the front surface of the door panel extends out from surrounding cabinets approximately 1/4" (6). For model 424FSG, if there are no surrounding cabinet surfaces to gauge depth, slide the unit back until it engages the anti-tip bracket.

IMPORTANT NOTE: The floor under the wine storage unit must be at the same level as the surrounding finished floor to allow for removal of the unit for servicing.