Models 427G and 427RG Installation

22

 

 

Position the Unit

Retract the front leveling legs all the way up to allow the unit to be moved into position more easily. You will extend the leveling legs when the unit is in its final position to reduce the possibility of the unit tipping forward.

Use an appliance dolly to move the wine storage unit near the rough opening. Position the dolly at the side of the unit to prevent damage to finished surfaces.

IMPORTANT NOTE: If for any reason the wine storage unit has been laid on its back or side, you must allow the unit to stand upright for a minimum of 24 hours before con- necting power.

Plug the power cord into the grounded electrical outlet. With power applied to the appliance, check for lighting and cooling before going any further. Once you are satis- fied that the unit is operating properly, shut off power to the electrical outlet at the circuit breaker and proceed.

Pre-level the wine storage unit before moving into position. This is to allow the unit to engage the anti-tip bracket properly.

If a home alarm system is to be used with the wine storage unit, the lead wires should be threaded into the compressor compartment before you position the unit. Refer to wiring connections on page 24 for the location of these lead wires. After the unit is in position, the alarm wiring can be completed from the front.

Slide the unit into position, making sure the anti-tip bracket is engaged properly. Extend the front leveling legs down approximately 3/16" (5) to make additional adjust- ments easier.

When the wine storage unit is installed, the anti-tip bracket will be positioned just below the engaging bracket on the unit. It is not necessary to raise the unit up so that it locks into the anti-tip bracket, but the unit must be in alignment with the anti-tip bracket.