Models 424G and 424FSG Installation | 12 |
|
|
Kickplate Installation
Once the unit is leveled and wiring connections made, the kickplate can be installed. Use the two #10 x 1/2" stainless steel screws that are provided with the kickplate. Refer to the illustration below.
IMPORTANT NOTE: The kickplate must be removed for servicing. The floor cannot interfere with removal. The louvered section of the kickplate must not be covered so as to prevent air circulation.
Turn power back on to the electrical outlet.
Door Panel
MODEL 424G
Model 424G is offered in two design applications; stain- less steel (/S) and overlay (/O). Each of these designs have a
The stainless steel model 424G/S is shipped from the factory with the decorative stainless steel door panel and matching handle in place.
The overlay model 424G/O is designed to accept a deco- rative door panel to match surrounding cabinetry. The door panel and the handle will be provided by the customer.
KICKPLATE |
Before beginning installation, check for the correct com- ponents for the fit and finish desired. All overlay doors require a decorative panel 233/4" (603) x 301/16" (764), a minimum 5/8" (16) thick.
IMPORTANT NOTE: For installations at or above 5,000' (1524 m) in altitude, a special high altitude glass door unit (HAG) must be ordered.
If you have questions, contact your authorized
Kickplate installation.
A solid panel cannot be installed over the glass door, as this may cause moisture to form behind the panel.